• Title/Summary/Keyword: pitch measurement

Search Result 265, Processing Time 0.026 seconds

Verification of Navigation System of Guided Munition by Flight Experiment (비행 실험을 통한 유도형 탄약 항법 시스템 검증)

  • Kim, Youngjoo;Lim, Seunghan;Bang, Hyochoong;Kim, Jaeho;Pak, Changho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.11
    • /
    • pp.965-972
    • /
    • 2016
  • This paper presents results of flight experiments on a navigation algorithm including multiplicative extended Kalman filter for estimating attitude of the guided munition. The filter describes orientation of aircraft by data fusion with low-cost sensors where measurement update is done by multiplication, rather than addition, which is suitable for quaternion representation. In determining attitude from vector observations, the existing approach utilizes a 3-axis accelerometer as a 2-axis inclinometer by measuring gravity to estimate pitch and roll angles, while GNSS velocity is used to derive heading of the vehicle. However, during accelerated maneuvers such as coordinated flight, the accelerometer provides inadequate inclinometer measurements. In this paper, the measurement update process is newly defined to complement the vulnerability by using different vector observations. The acceleration measurement is considered as a result of a centrifugal force and gravity during turning maneuvers and used to estimate roll angle. The effectiveness of the proposed method is verified through flight experiments.

Multi-Objective Onboard Measurement from the Viewpoint of Safety and Efficiency (안전성 및 효율성 관점에서의 다목적 실선 실험)

  • Sang-Won Lee;Kenji Sasa;Ik-Soon Cho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.116-118
    • /
    • 2023
  • In recent years, the need for economical and sustainable ship routing has emerged due to the enforced regulations on environmental issues. Despite the development of weather forecasting technology, maritime accidents by rough waves have continued to occur due to incorrect weather forecasts. In this study, onboard measurements are conducted to observe the acutal situation on merchant ships in operation encountering rough waves. The types of measured data include information related to navigation (Ship's position, speed, bearing, rudder angle) and engine (engine revolutions, power, shaft thrust, fuel consumption), weather conditions (wind, waves), and ship motions (roll, pitch, and yaw). These ship experiments was conducted to 28,000 DWT bulk carrier, 63,000 DWT bulk carrier, 20,000 TEU container ship, and 12,000 TEU container ship. The actual ship experiment of each ship is intended to acquire various types of data and utilize them for multi-objective studies related to ship operation. Additionally, in order to confirm the sea conditions, the directional wave spectrum was reproduced using a wave simulation model. Through data collection from ship experiments and wave simulations, various studies could be proceeding such as the measurement for accurate wave information by marine radar and analysis for cargo collapse accidents. In addition, it is expected to be utilized in various themes from the perspective of safety and efficiency in ship operation.

  • PDF

Cross-sectional Design and Stiffness Measurements of Composite Rotor Blade for Multipurpose Unmanned Helicopter (다목적 무인헬기 복합재 로터 블레이드의 단면 구조설계 및 강성 측정)

  • Kee, Young-Jung;Kim, Deog-Kwan;Shin, Jin-Wook
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.52-59
    • /
    • 2019
  • The rotor blade is a key component that generates the lift, thrust, and control forces required for helicopter flight by the torque transmitted through the hub and the blade pitch angle control, and should be designed to factor vibration characteristics so that there is no risk of resonance with structural safety. In this study, the structural design of the main rotor blade for MPUH(Multi-Purpose Unmanned Helicopter) was conducted and the sectional stiffness measurement of the fabricated blade was performed. The evaluation of the vibration characteristics of the main rotor system was then conducted factoring the measured stiffness distribution. The interior of the rotor blade comprised of the skin, spar, and torsion box, and carbon and glass fiber composites were applied. The Ksec2D program was applied to predict the stiffness of blade, and the results were compared to the measured data. CAMRADII, a comprehensive rotorcraft analysis program, was applied to investigate the natural frequency trends and resonance risks due to the rotor rotation.

Effect of Taping Therapy and Inner Arch Support on Plantar Lower Body Alignment and Gait

  • Lee, Sojung;Jeong, Dawun;Kim, Dong-Eun;Yi, Kyungock
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.229-238
    • /
    • 2017
  • Objective: The purpose of this study was to identify the effects of taping therapy and inner arch support on pes planus lower extremity alignment and gait. Method: The study was conducted on 13 women in their 20s who had pes planus and no gait problems. Independent variables were the condition of wearing basic socks (S1) and the condition of wearing socks with taping therapy and inner arch support (S2). The dependent variables were resting calcaneal stance position (RCSP), plantar pressure distribution during gait, and underlying and medial longitudinal arch angle measured using radiography. Statistical analysis was performed using the Wilcoxon test with SPSS 23.0 for comparison of S1 and S2. Results: In the RCSP measurement, the angle range of S2 changed to normal. Meary's angle appeared to be less than the angle of S1, indicating alleviation of the degree of pes planus. The calcaneal pitch angle increased at S2 from that at S1. The plantar pressure distribution was divided into four areas (toe, forefoot, midfoot, and hindfoot). At S2, the maximum pressure increased in the toe and midfoot. The maximum force increased significantly in the toe and midfoot but decreased significantly in the forefoot and hindfoot. In addition, the contact area increased overall especially at the midfoot and hindfoot. Contact time decreased in the toe and forefoot, but increased in the midfoot and hindfoot. Conclusion: Taping therapy and inner arch support showed structural improvement of the pes planus. In addition, the force and pressure applied to the foot during walking are distributed evenly in the area of the sole, thus positively affecting walking.

Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector (비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가)

  • Park, Ji-Koon;Kang, Sang-Sik;Cho, Sung-Ho;Shin, Jung-Wook;Kim, So-Yeong;Son, Dae-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.

Clinical Utility of Radiographic Measurements of Insertional Achilles Tendinitis with Haglund's Deformity (Haglund씨 변형을 동반한 부착부 아킬레스 건염에서의 방사선학적 측정치의 임상적 유용성)

  • Kim, Kyung-Chul;Shin, Hun-Kyu;Kang, Dong-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.188-192
    • /
    • 2005
  • Purpose: It is to analyze the clinical utility of radiograhpic measurements for the insertional Achilles tendinitis patients who have Haglund's deformity and to evaluate the radiographic values related to Haglund's deformity in normal Korean population. Materials and Methods: We used the angle of Fowler and Philip, parallel pitch lines (PPL) and Chauveaux-Liet (CL) angle as radiographic measurements. We examined 50 cases of insertional Achilles tendinits patients and another 50 cases of normal foot as a control. Results: In normal feet, the mean value of angle of Fowler and Philip was $53.22^{\circ}$, CL angle was $-33.14^{\circ}$ and the PPL showed positive in 48%. In case of insertional Achilles tendinitis, the mean values were $55.39^{\circ}$, $-33.63^{\circ}$, positive in 56% respectively. There were not statistically significant differences (p>0.05). Conclusion: The radiographic values for Haglund's deformity between insertional Achilles tendinitis feet and the normal feet did not show significant difference. Therefore, it seems that the clinical utility of radiographic measurements for the insertional Achilles tendinitis with Haglund's deformity is not useful and the development of new diagnostic methods as MRI and ultrasonography is required.

  • PDF

Acoustic Characteristics on the Adolescent Period Aged from 16 to 18 Years (16~18세 청소년기 음성의 음향음성학적 특성)

  • Ko, Hye-Ju;Kang, Min-Jae;Kwon, Hyuk-Jae;Choi, Yaelin;Lee, Mi-Geum;Choi, Hong-Shik
    • Phonetics and Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.81-90
    • /
    • 2013
  • During adolescence the mutational period is characterized by the changes in the laryngeal structure, the length of the vocal cords, and a tone of voice. Usually, adolescents at 15 or 16 reach the voice of adults but the mutational period is sometimes delayed. Therefore, studies on the voice of adolescents between 16 ~ 18 right after the mutational period are required. Accordingly, this paper attempted to provide basic data about the normal standard for patients with voice disorders during this period by evaluating the vocal characteristics of males and females between 16 ~ 18 with an objective device bycomparing and analyzing them by sex and age. The study was conducted on a total of 60 subjects composed of each 10 subjects of each age. The vocal analysis was conducted by MPT (Maximum Phonation Time) measurement, sustained vowels and sentence reading. As for /a/ sustained vowels, fundamental frequency, hereinafter referred to as $F_0$, jitter, shimmer, noise-to-harmonic ratio, hereinafter referred to as NHR were measured by using the Multi-dimensional voice program (MDVP) among the Multi-Speech program of Computerized Speech Lab (Kay Elemetrics). The sentence reading, mean $F_0$, maximum $F_0$ and minimum $F_0$ were measured using the Real-Time Pitch (RTP) Model 5121 among the Multi-Speech program of Computerized Speech Lab (Kay Elemetrics). As a result, according to sex, there were statistically significant differences in $F_0$, jitter, shimmer, mean $F_0$, maximum $F_0$, and minimum $F_0$; and according to age, there were statistically significant differences in MPT. In conclusion, the voice of the adolescents between 16 ~ 18 reached the maturity levels of adults but the voice quality which can be considered on the scale of voice disorders showed transition to the voice of an adult during the mutational period.

Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (I) - Effects of Rib Tubulators - (이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (I) - 요철 설치에 따른 영향 -)

  • Kim, Kyung-Min;Kim, Sang-In;Kim, Yun-Young;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.910-920
    • /
    • 2004
  • The heat/mass transfer characteristics in a rotating two-pass duct with and without rib turbulators are investigated in the present study. The square duct has a hydraulic diameter ($D_h$) of 26.7 mm, and $1.5\;mm{\times}1.5\;mm$ square $90^{\circ}$-rib turbulators are attached on the leading and trailing walls. The pitch-to-rib height ratio (p/e) is 10. The Reynolds number based on the hydraulic diameter is kept constant at 10,000 to exclude the Reynolds effect, and the rotation number is varied from 0.0 to 0.20. In the smooth duct, the curvature of the $180^{\circ}$-turn produces Dean vortices that enhance heat/mass transfer in the post-turn region. When rib turbulators are installed, heat/mass transfer is augmented 2.5 times higher than that of the smooth duct since the main flow is turbulated by reattaching and separating in the vicinity of the duct surfaces. The duct rotation results in heat/mass transfer discrepancy so that Sherwood number ratios are higher on the trailing surface in the first-pass and on the leading surface in the second-pass. In the turning region, Dean vortices shown in the stationary case transform into one large asymmetric vortex cell, and subsequent heat/mass transfer characteristics also change. As the rotation number increases, the heat/mass transfer discrepancy enlarges.

Development of a 6 degrees-of-freedom micro stage for ultra precision positioning (초정밀작업을 위한 6자유도 마이크로 스테이지의 개발)

  • Kim, Kyung-Chan;Kim, Soo-Hyun;Kwak, Yoon-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.372-379
    • /
    • 1998
  • A new 6 degrees-of-freedom micro stage, based on parallel mechanisms and actuated by using piezoelectric elements, has been developed for the application of micro positioning such as semiconductor manufacturing devices, high precision optical measurement systems, and high accurate machining. The micro stage structure consists of a base platform and an upper platform(stage). The base platform can effectively generates planar motion with yaw motion, while the stage can do vertical motion with roll and pitch motions with respect to the base platform. This separated structure has an advantage of less interference among actuators. The forward and inverse kinematics of the micro stage are discussed. Also, through linearization of kinematic equations about an operating point on the assumption that the configuration of the micro stage remains essentially constant throughout a workspace is performed. To maximize the workspace of the stage relative to fixed frame, an optimal design procedure of geometric parameter is shown. Hardware description and a prototype are presented. The prototype is about 150mm in height and its base platform is approximately 94mm in diameter. The workspace of the prototype is obtained by computer simulation. Kinematic calibration procedure of the micro stage and its results are presented.

A Study on Dynamic Characteristics of Tipjet Rotor (팁젯 방식으로 구동하는 로터의 동특성 연구)

  • Baek, Sang-Min;Kwon, Jae-Ryong;Rhee, Wook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.1
    • /
    • pp.52-58
    • /
    • 2018
  • A Study on the dynamic characteristics of a rotor driven by a tipjet system in hovering condition was carried out. The sectional modeling was performed for the tipjet blade in which the flow path was inserted, and the dynamic characteristics analysis was conducted by modeling the components of the proposed rotor system. The analysis was conducted with respect to the rotational speed and the collective pitch. As a result of the analysis, it was checked that the proposed tipjet rotor did not have aeroelastic instability within the designed operating range. The tipjet test equipment was constructed in order to verify the analysis approach. It was confirmed that the proposed rotor was driven normally by tipjet. The non-rotating eigenmode measurement test and the rotation test were performed, and the validity was proved by comparing the test results and the analysis results.