• 제목/요약/키워드: pitch measurement

검색결과 264건 처리시간 0.022초

나사 리드 측정시스템 개발 (Development of The Screw Lead Measurement System)

  • 최종근;최현철;김형선
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.7-13
    • /
    • 2007
  • This study proposes a new screw measurement system that is capable of measuring the pitch or lead of a screw, which is one of the most important parameters representing the screw quality. There are various conventional methods for screw measurement including some mechanical and optical ones, but they can not be applied to measure the lead except the profiles or sizes. The newly suggested method is able to measure the pitch or lead directly. This is executed by scanning the thread with a digital probe while the target screw rotates. The devised measurement system is a integrated computer system which is composed of a stepping motor, a digital linear gauge and a chuck device for holding the measured screw. In order to operate the system effectively and conveniently, a computer program having graphical user interface facility is developed. Some experiments were done to prove the effectiveness of the system.

레이저를 이용한 볼나사 리드오차 측정에 관한 연구

  • 윤영식;박철우;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 1994
  • Recently, the precision ball screw becomes the essence of the high-precision industries and is playing a key role in the positioning devices. The standard and definition of pitch error in a precision ball screw is specified by KS, JIS or ISO. However, the method of measuring the pitch error is not concrete. In this study. laser measurement system(LMS) with a laser position transducer and a machine-tools is developed. In order to verify the stability of the LMS, several experiments with the standard ball screw is performed.

  • PDF

CNC 공작기계 선형피치오차의 최적 보정 알고리즘을 구현하는 자동측정 및 보정 시스템의 개발

  • 이석원;박희재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.297-302
    • /
    • 1997
  • Linear displacement accuracy is one of the most important factors that determine machine tool accuracy. The laser interferometer has been usually recommended for the measurement of linear displacement accuracy. In this paper, microcomputer aided measurement and compensation system has been developed forthe pitch error in a CNC machine tool. For accurate pitch error calculation, the analysis code for the pitch error has been also implemented according to the international standards(ISO). The PC based automatic compensation system for the pitch error is also implemented. A new algorithm for calculating optimum value for pitch error compensation is proposed, minimizing the deviation at each target points. The development system has been applied to a practical CNC maching center and the performance has been demonstrated.

억양의 근접복사 유형화를 이용한 감정음성의 음향분석 (An acoustical analysis of emotional speech using close-copy stylization of intonation curve)

  • 이서배
    • 말소리와 음성과학
    • /
    • 제6권3호
    • /
    • pp.131-138
    • /
    • 2014
  • A close-copy stylization of intonation curve was used for an acoustical analysis of emotional speech. For the analysis, 408 utterances of five emotions (happiness, anger, fear, neutral and sadness) were processed to extract acoustical feature values. The results show that certain pitch point features (pitch point movement time and pitch point distance within a sentence) and sentence level features (pitch range of a final pitch point, pitch range of a sentence and pitch slope of a sentence) are affected by emotions. Pitch point movement time, pitch point distance within a sentence and pitch slope of a sentence show no significant difference between male and female participants. The emotions with high arousal (happiness and anger) are consistently distinguished from the emotion with low arousal (sadness) in terms of these acoustical features. Emotions with higher arousal show steeper pitch slope of a sentence. They have steeper pitch slope at the end of a sentence. They also show wider pitch range of a sentence. The acoustical analysis in this study implies the possibility that the measurement of these acoustical features can be used to cluster and identify emotions of speech.

한국어의 점진하강(declination) 연구를 위한 음높이 측정 위치와 기준선 고찰 (A Study of the Pitch Measurement Location and Reference Line for a Research of Declination in Korean)

  • 곽숙영;신지영
    • 말소리와 음성과학
    • /
    • 제1권2호
    • /
    • pp.75-84
    • /
    • 2009
  • The aim of this paper is to find an adequate method to study declination in Korean. In previous studies of declination in Korean, maximum and minimum pitch values in an accentual phrase were measured. But this method is inadequate when an accentual phrase is located at the intonational phrase. So in order to exclude the final tone of an intonational phrase, we propose to measure pitch values of the first and second tone in an accentual phrase when the tonal pattern of the accentual phrase is 'LHLH'. In this case, the line that connects every first tone of an accentual phrase is the baseline, and the line that connects every second tone of an accentual phrase is the topline. By a comparison of declination between focused and neutral utterances, we will show that the topline of declination is more direct to the speaker's plan than the baseline.

  • PDF

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)

삼직교 열선유속계의 간편한 측정법 개발 (Development of Easy Measurement Method of Orthogonal Triple-Sensor Hot-Wire Anemometer)

  • 김진권;강신형
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.85-92
    • /
    • 2000
  • Easy measurement method of orthogonal triple-sensor hot-wire anemometer is developed. Advantages of the new method is that it does not require either the exact orthogonality of the installed wires which cannot be kept during the probe manufacture and repair, nor the knowledge of the wire installation angles and the yaw and pitch coefficient of the wires. The new method introduced yaw and pitch calibration coefficients which are designed to increase monotonically with yaw and pitch angles. So the resulting calibration network is simple to recognize compared with that of the previously suggested calibration method. Verification experiments showed good accuracy and independency of the directional calibration on velocity.

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권4호
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

길이 표준 소급성을 갖는 원자간력 현미경을 이용한 2차원 격자 시편 측정과 불확도 평가 (Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation)

  • 김종안;김재완;강주식;엄태봉
    • 한국정밀공학회지
    • /
    • 제24권9호
    • /
    • pp.68-75
    • /
    • 2007
  • The pitch and orthogonality of two-dimensional (2D) gratings have been measured by using a metrological atomic force microscope (MAFM) and measurement uncertainty has been analyzed. Gratings are typical standard artifacts for the calibration of precision microscopes. Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2D gratings, it is important to certify the pitch and orthogonality of 2D gratings accurately for nano-metrology using precision microscopes. In the measurement of 2D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme was required to overcome some limitations of current MAFM such as nonnegligible thermal drift and slow scan speed. Two kinds of 2D gratings, each with the nominal pitch of 300 nm and 1000 nm, were measured using line scans for the pitch measurement of each direction. The expanded uncertainties (k = 2) of measured pitch values were less than 0.2 nm and 0.4 nm for each specimen, and those of measured orthogonality were less than 0.09 degree and 0.05 degree respectively. The experimental results measured using the MAFM and optical diffractometer were coincident with each other within the expanded uncertainty of the MAFM. As a future work, we also proposed another scheme for the measurements of 2D gratings to increase the accuracy of calculated peak positions.

무향 칼만 필터를 이용한 무인 운송체의 자세 추정 (Attitude Estimation of Unmanned Vehicles Using Unscented Kalman Filter)

  • 송경섭;고낙용;최현승
    • 한국전자통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.265-274
    • /
    • 2019
  • 본 논문은 저가형 AHRS(: Attitude Heading Reference System)센서를 이용하여 무인 운송체(Unmanned vehicle)의 자세를 무향 칼만 필터 (Unscented Kalman filter)통해 추정하는 방법을 제안한다. 측정된 가속도와 지구자기장 값을 이용하여 UKF의 보정 단계에서 사용될 자세를 계산한다. 롤 (roll)과 피치 (pitch)는 가속도로부터 구해지며 요 (yaw)는 지구 자기장을 이용하여 연산한다. 이때 사용되는 지구자기장 측정값은 강철 효과(hard-iron effect)와 연철 효과(soft-iron effect)에 의해 쉽게 왜곡되기 때문에 계산된 요의 불확실성이 롤이나 피치의 불확실성에 비하여 크다. 본 논문은 이러한 불확실성을 줄이기 위하여 측정된 지구자기장에 포함된 편차성분을 추정하고 보정하여 더 정밀한 요값을 구한다. 제안된 방법을 수조에서의 무인 운송체 항법 실험을 통하여 검증하였다. 실험결과, 자세 추정 성능이 개선되고 이에 따라 위치 추정 성능도 개선됨을 확인하였다.