• 제목/요약/키워드: pitch measurement

검색결과 264건 처리시간 0.032초

호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구 (A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE)

  • 조수미;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

고속 자율 무인잠수정 적용을 위한 MEMS 기술기반 자세 측정 장치 개발 (Development of Attitude Heading Reference System based on MEMS for High Speed Autonomous Underwater Vehicle)

  • 황아롬;안남현;윤선일
    • 해양환경안전학회지
    • /
    • 제19권6호
    • /
    • pp.666-673
    • /
    • 2013
  • 본 연구는 빠른 운항 속도와 짧은 운용 시간을 요구하는 임무에 활용될 저가 소형 자율 무인잠수정에 고가 대형 관성 측정 장치를 대신하여 사용할 수 있는 저가 소형 자세 측정 장치 개발 및 성능 검증을 수행하였다. 저가 소형 자세 측정 장치 개발을 위해서 MEMS 기술을 적용한 gyro, accelerometer 및 magnetometer 채택하여 MEMS 기반 하드웨어를 제작하였으며, 좌표 변환 공식과 칼만 필터를 적용하여 자세 계산 알고리즘을 구현하였다. 또한 개발된 MEMS 기반 자세 측정 장치에 대한 기본 성능 검증을 위한 지자기센서 검증 시험, 정적 자세 시험, 차량 시험, 운동 모사 장치 시험을 수행하였으며, 각각 시험 결과를 제시하였다. 지자기센서 검증 시험 결과 외부 자기장 보정을 통하면 개발된 MEMS 기반 자세 측정 장치의 측정 결과가 외부 자기장에 강인함을 확인하였으며, 정적 자세 시험 및 차량 시험을 통하여 자세 변화가 크지 않는 환경에서 자세 측정 오차가 $0.5^{\circ}/hr$ 임을 확인하였다. 운동 모사 장치 시험을 통하여 5분 내외 자세 변화가 큰 운동 중에도 자세 측정 오차가 발산하지 않고 $1^{\circ}/hr$ 이내임을 확인하였다. 상기 시험 결과로부터 개발된 MEMS 기반 자세 측정 장치가 목표 성능인 $1^{\circ}/hr$이내 roll, pitch, yaw 오차를 보여주고 있음 확인하였으며, 이로부터 20분 내외 운용 시간 동안 정확한 자세 정보 제공 가능성을 확인할 수 있었다.

정밀한 선형 횡변위 측정용 elongated circular 격자의 자체결상을 이용한 무아레 무늬의 신호처리법 (The signal processing of moire fringes obtained by the superposition of a fixed self-imaging elongated circular(EC) grating and a moved EC grating for the precise measurement of linear transverse displacements)

  • 이상일;백승선;조재흥
    • 한국광학회지
    • /
    • 제15권5호
    • /
    • pp.435-442
    • /
    • 2004
  • 직선격자와 원형격자의 혼합형태인 EC(Elongated circular) 격자의 무아레 무늬로 수 $\mu\textrm{m}$의 선형 횡변위를 보기 위하여 자체결상법으로 무아레 무늬를 형성하고 이를 신호처리하여 횡변위를 정밀하게 측정하였다. CCD 카메라로 측정한 무아레 무늬의 직선격자 부분을 고주파 필터링(filtering)과 스무딩(smooothing) 및 2차함수 피팅(fitting)하고, 이 결과의 1차 미분으로부터 영점교차의 위치를 세어서 직선격자 부분의 밝은 무늬의 위치를 측정하였다. 그리고 EC격자의 원형격자 부분에 의한 무아레 무늬는 고주파 필터링과 스무딩으로 구한 결과의 1차 미분에서 나온 영점교차 개수로부터 원형격자의 밝은 부분의 개수를 셈으로써 선형 횡변위의 EC격자 피치에 대한 정수배의 선형이동량을 정확히 계측하였다. 이 결과 80 $\mu\textrm{m}$ 이하의 횡변위에 대해서 지금까지 무아레 무늬로부터 가시적으로 구한 선형 횡변위량보다 훨씬 정확한 3% 이하의 정확도로 횡변위를 구할 수 있었다.

테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes)

  • 이장호;김형대;김정배;김무환
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

비균질 도시 지표에서 측정된 에디 공분산 난류 플럭스의 불확실성 분석: 좌표계 편향 영향 (Uncertainty Analysis of the Eddy-Covariance Turbulent Fluxes Measured over a Heterogeneous Urban Area: A Coordinate Tilt Impact)

  • 이두일;이재형;이상현
    • 대기
    • /
    • 제26권3호
    • /
    • pp.473-482
    • /
    • 2016
  • An accurate determination of turbulent fluxes over an urban area is a challenging task due to its morphological diversity and associated flow complexity. In this study, an eddy covariance (EC) method is applied over a highly heterogeneous urban area in a small city (Gongju), South Korea to investigate the quantitative influence of 'coordinate tilt' in determining the turbulent fluxes of sensible heat, latent heat, momentum, and carbon dioxide mass. Two widely-used coordinate transform methods are adopted and applied to eight directional sections centered on the site to analyze a 1-year period EC measurement obtained from the urban site: double rotation (DR) and planar fit (PF) transform. The results show that mean streamline planes determined by the PF method are distinguished from the sections, representing morphological heterogeneity of the site. The sectional pitch angles determined by the DR method also compare well with those in the PF method. Both the PF and DR methods show large variabilities in the determined streamline planes at each directional section, implying that flow patterns may form in a complicate way due to the surface heterogeneity. Resulting relative differences of the turbulent fluxes, defined by $(F_{DR}-F_{PF})/F_{DR}$, are found on average +13% in sensible heat flux, +21% in latent heat flux, +37% in momentum flux, and +26% in carbon dioxide mass flux, which are larger values than those reported previously for fairly homogeneous natural sites. The fractional differences depend significantly on wind direction, showing larger differences in northerly winds at the measurement site. It is also found that the relative fractional differences are negatively correlated with the mean wind speed at both stable/unstable atmospheric conditions. These results imply that EC turbulent fluxes determined over heterogeneous urban areas should be carefully interpreted with considering the uncertainty due to 'coordinate tilt' effect in their applications.

한국어 파열자음의 특성에 관한 연구 (The Study on the Characteristics of Korean Stop Consonants)

  • 서동일;표화영;강성석;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제8권2호
    • /
    • pp.217-224
    • /
    • 1997
  • The present study was performed to investigate the voice onset time(VOT) of Korean stop consonants as the expanded research of Pyo and Choi(1996) : the intensity, and the air flow rate of Korean stops as the preliminary study f3r the classical singing training. Nine Korean stops(/P, P', $P^{h}$/, /t, t', $t^{h}$/, /k, k', $k^{h}$/) and a vowel /a/ were used as speech materials. CV and VCV syllable patterns were used for VOT measurement, and CV pattern was used for intensity and air flow rate measurement. Five males and five females pronounced the speech tasks with comfortable pitch and intensity : VOT, intensity, and air flow rate were measured. As results, the prevocalic stop consonants showed bilabials, the shortest VOT and velars, the longest one, except the unaspirated stops which showed the shortest was velar /k'/, and the alveolar /t'/ was the longest. Considering the tensity, heavily aspirated stops showed the longest, and the unaspirated, the shortest. Also the intervocalic stops showed similar results with the prevocalic stops, except the slightly aspirated stops which showed alveolar sound was the longest, and the bilabials, which showed the shortest was the slightly aspirated /p/, unlike the prevocalic stops, the unaspirated /p'/ the shortest. All of prevocalic stops showed the highest air flow rate in heavily aspirated stops, the second, thee slightly aspirated ones, and the lowest was the unaspirated stops. And as a whole, bilabials were the highest, and velars, the lowest, except in the heavily aspirated stops, which was the alveolar sound, the lowest. In the dimension of intensity, the unaspirated and bilabials were the highest, and the heavily aspirated and velars were e lowest, except the slightly aspirated stops, which were the bilabials the lowest, and the alveolars the highest.

  • PDF

영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향 (Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

PHR 자기센서를 적용한 탐침형 전류 프로브 (A pin type current probe using Planar Hall Resistance magnetic sensor)

  • 이대성;이남영;홍성민;김철기
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.342-348
    • /
    • 2021
  • For the characterization or failure analysis of electronic devices such as PCB (printed circuit boards), the most common method is the measurement of voltage waveforms with an oscilloscope. However, because there are many types of problems that cannot be detected by voltage waveform analysis, several other methods such as X-ray transmission, infrared imaging, or eddy current measurement have been applied for these analyses. However, these methods have also been limited to general analyses because they are partially useful in detecting physical defects, such as disconnections or short circuits. Fundamentally current waveform measurements during the operation of electronic devices need to be performed, however, commercially available current sensors have not yet been developed, particularly for applications in highly integrated PCB products with sub-millimeter fine pitch. In this study, we developed a highly sensitive PHR (planar hall resistance) magnetic sensor for application in highly integrated PCBs. The developed magnetic sensor exhibited sufficient features of an ultra-small size of less than 340 ㎛, magnetic field resolution of 10 nT, and current resolution of 1 mA, which can be applicable for PCB analyses. In this work, we introduce the development process of the magnetic sensing probe and its characteristic results in detail, and aim to extend this pin-type current probe to applications such as current distribution imaging of PCBs.

어패럴 CAD System의 활용화 방안 연구(II) - 테일러드 쟈켓 설계 과정을 중심으로 - (A Study on the Application of the Apparel CAD System(II))

  • 남윤자;이형숙;조영아
    • 한국의류학회지
    • /
    • 제18권1호
    • /
    • pp.43-56
    • /
    • 1994
  • The Purpose of this study was to utilize of CAD System in pattern making process for women's apparel. The automation by the use of CAD System provides the higher accuracy and efficiency in pattern making process. AccuMark 300 System was used. for .this study. The results from this study were as follows . 1. New size spec chart and grading pitch chart were developed based on the data analysis and fitting tests for female college students. 2. New jacket block was developed based on the torso length sloper 3. Automatic grading of jacket block have been developed by creation and modification of grading rules of block pattern. 4. Pattern Design Systyem(P/D/S) were enabled to be constructed directly form a block pattern by modifications to existing styled pattern. 5. Original master pattern was generated by P/D/S menu option. 6. Production pattem added seam allowance, notchs was generated by P/D/S menu option. 7 Interative maker making process have enabled to save a wide range of time and space. 8. Measurement of garment by P/D/S measuring tools is to utilize in garment costing, quality control.

  • PDF

쿼드로터의 자율비행을 위한 로보스트 제어기 설계 (Quad-rotor Robust Controller Design for Autonomous Flight)

  • 김민;변기식;김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.539-540
    • /
    • 2012
  • 최근까지 무인 항공기는 군사적인 목적으로 활용하기 위해 활발하게 연구 되어 왔다. 근래에 들어 레저용, 또는 상업용으로 활용도가 급격히 증대되고 있다. 이에 국내외의 대학 및 연구기간에서 무인항공기의 자동비행 제어시스템을 위한 연구를 활발히 진행되고 있다. 최근 들어 무인항공기로 제어하기가 쉽고 활용도가 높은 쿼드로터 비행체가 각광을 받고 있는데 이미 많은 연구가 진행되어 왔다. 이러한 쿼드로터는 4개의 로터의 속도 제어로 비행체의 위치제어가 가능하다. 쿼드로터의 구조적인 이점으로 제어가 쉬운 반면 바람과 같은 외란에 매우 취약하다는 단점이 있어 실제 위치 제어가 쉽지가 않다. 본 논문에서는 외란(disturbance)에 취약한 쿼드로터의 위치제어를 안정하게 제어하기 위해 비행체의 자세 측정 센서인 관성측정장치(Inertial Measurement Unit)를 만들어 비행체의 자세를 측정 할 수 있도록 하였다. IMU는 자이로(Gyro)와 가속도(Accelerometer) 센서를 융합하여 비행체의 Roll, Pitch, Yaw 자세를 계측할 수 있도록 하였다. 본 논문에서는 일반적인 PID 제어기법을 적용하여 기존의 쿼드로터의 비행체에 대한 제어 성능을 실험을 제시하고자 한다.

  • PDF