• Title/Summary/Keyword: pitch length

Search Result 305, Processing Time 0.021 seconds

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

A Study on the Detection and the Correction of Prosodic Errors Produced by Chinese Korean-Learners (중국인 학습자들의 한국어 강세구 실현양상과 오류진단 및 교정방안 연구)

  • Yune, Young-Sook
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.51-59
    • /
    • 2012
  • The purpose of this study is to examine the pitch pattern of Korean accentual phrases produced by Chinese Korean-learners in the reading of a Korean text. Korean accentual phrase is determined by a specific F0 contour. And the pitch contour of APs differ depending on their length and the nature of initial segment. In order to examine if Chinese speakers are also aware such a phonetic properties, we have examined the AP pitch contours produced by 15 Chinese speakers differing in proficiency, and compared them to pitch contours produced by six Korean native speakers. The results show that Chinese speakers' pitch errors were observed in initial segment-tone interaction and in type of pitch patterns. However, even though Chines speakers produced the same type of pitch patterns, internal tonal modulation differs from native speakers. Finally, on the basis of theses results, we proposed a teaching method that visualizes the F0 contour.

A Study of the Prosodic Characteristics of Homographs with Context Cues by Subjects with Right and Left Hemisphere Damage (문맥 내에서 좌우반구 손상자의 동음어에 대한 운율 산출 비교)

  • Lee, Myoung-Soon
    • Phonetics and Speech Sciences
    • /
    • v.2 no.1
    • /
    • pp.13-21
    • /
    • 2010
  • The purpose of this study was to examine the prosody characteristics of sentence-level utterances which contain homographs with context cues in patients with neurogenic communication disorders. Homographs which may be affected by prosody, especially tonic length features, were used to investigate this matter. The characteristics of tone, duration, pitch, and pitch peak were analyzed to examine the characteristics of prosody in patients with lesions in the left or right hemisphere and normal controls. The whole process was recorded using Praat 4.3.14 and for statistical analyses, three-way ANOVA and multiple comparative analyses, Chi-Square tests, and a one-way ANOVA were carried out using SPSS 12.0 for Windows. The conclusions of this study are as follows. First, the length of syllables and vowels in homographs in Korean was different depending on the meaning and was not significant between groups. Second, it was found that patients with lesions in the right hemisphere had significant difference on pitch. Third, it was found that frequency of pitch peak and tone in 'short' tone syllables were different between groups. The conclusion of this study found that the prosody of homographs between groups absolutely was not differentiated. Accordingly, more detailed studies of acoustic parameters and other parameters which the prosody characteristic between groups could be found are needed in the future.

  • PDF

Certification of magnification standards for the establishment of meter-traceability in microscopy (현미경의 길이표준 소급성 확립을 위한 배율 교정 시편 인증)

  • Kim J.A.;Kim J.W.;Park B.C.;Eom T.B.;Kang C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.645-648
    • /
    • 2005
  • Microscopy has enabled the development of many advanced technologies, and higher level microscopic techniques are required according to the increase of research in nano-technology and bio-technology fields. Therefore, in many applications, we need to measure the dimension of micro-scale parts accurately, not just to observe their shapes. To establish the meter-traceability in microscopy, gratings have been widely used as a magnification standard. KRISS provides the certification service of magnification standards using an optical diffractometer and a metrological AFM (MAFM). They are based on different measurement principles, and so can give complementary information for each other. In this paper, we describe the configuration of each system and measurement procedures to certificate grating pitch values of magnification standards. Several measurement results are presented, and the discussion about them are also given. Using the optical diffractometer, we can calibrate a grating specimen with uncertainty of less than 50 pm. The MAFM can measure a grating specimen of down to 100 nm pitch value, and the calibrated values usually have uncertainty less than 500 pm.

  • PDF

Characteristic Investigation According to Structures of Embroidered Radiation Patches at SF-MPAA (SF-MPAA의 자수된 방사체의 구조에 따른 특성 분석)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.21-26
    • /
    • 2020
  • In this paper, we investigated the characteristics of SF-MPAA depend on the structures of radiators when they were embroidered for realizing embroidered SF-MPAA. As increasing pitches by decreasing numbers of grids in length-direction and width-direction of the embroidered radiator the antenna gain and resonance frequency were trendingly decreased. However the characteristics of antenna were affected very much by the pitch in width-direction but affected relatively less by the pitch in length-direction. Therefore it was beneficial to decrease number of grids in length-direction to decrease conductor ratio. SLL was affected by the combination of length-direction pitch and width-direction pitch. The conductor ratio of embroidered radiator was determined by the ratio of pitch to embroidered thread thickness. When the ratio was less than 5 the conductor ratio was decreased rapidly. But when the ratio was larger than 5 the conductor ratio was decreased slowly and saturated.

Correlation Between the External Laryngeal Length and the Habitual Speaking Fundamental Frequency (외 후두부 길이와 발화기본주파수 간의 상관관계)

  • Nam, Do-Hyun;Rheem, Sung-Sue;Choi, Hong-Sik
    • Phonetics and Speech Sciences
    • /
    • v.1 no.4
    • /
    • pp.187-193
    • /
    • 2009
  • For this study, the external laryngeal lengths of 9 females and 9 males with normal voices were measured together with their ages, heights, and weights, and after they read aloud sentences for 3 minutes, their habitual speaking fundamental frequencies, speaking low pitches, speaking high pitches, and vocal fold closed quotients were measured. The Spearman rank correlation analysis on these data showed a significant negative correlation between the external laryngeal length and the habitual speaking fundamental frequency for both females and males, a significant negative correlation between the external laryngeal length and the speaking high pitch for only males, a significant negative correlation between the external laryngeal length and the speaking low pitch for both females and males, and a significant positive correlation between the external laryngeal length and the vocal fold closed quotient for only males.

  • PDF

A STUDY ON THE MECHANICAL CHARACTERISTICS OF RESISTANCE MULTI-SPOT WELDED JOINTS WITH PITCH LENGTH

  • Bang, Han-Sur;Bang, Hee-Seon;Joo, Sung-Min;Chang, Woong-Seong;Lee, Chang-Woo
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.809-815
    • /
    • 2002
  • For clarifying the mechanical phenomena of thermal elasto-plastic behavior on the multi-spot welded joints, this study has tried to carry out three-dimensional thermal elasto-plastic analysis on them. However, because the shape of multi-spot welded joints is not axi-symmetric, unlike the case of single-spot welded joint, the solution domain for simulation should be three-dimensional. Therefore, in this paper, from the results analyzed using the developed the three dimensional unstationary heat conduction and thermal elasto-plastic programs by an iso-parametric finite element method, mechanical characteristics and their production mechanism on single- and multispot welded joints were clarified. Moreover, effects of pitch length on temperature, welding residual stresses and plastic strain of multi-spot welded joints were evaluated, indicating that a pitch of 30mm was advantageous compared to a pitch of 15mm.

  • PDF

Tooth Profile Design of an Oval Gear According to the Curvature of the Pitch Curve (오벌기어의 피치곡선 곡률에 따른 치형 설계)

  • Lee, Sung-Chul
    • Tribology and Lubricants
    • /
    • v.28 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Oval gears are typical kinds of non-circular gears and are widely used in flow meters. This paper presents a tooth profile design of an oval gear according to the curvature of the pitch curve. The length of the pitch oval is divided by the number of teeth and the curvature of the divided points is obtained. The tooth profile is designed on the circle of the curvature as if it is the pitch circle of a gear. The teeth of the oval gear have the same module and pressure angle, but the pitch circle of each tooth differs in size. Thus, the teeth on the divided points of the pitch oval are different in shape. This type of oval gear will improve the meshing properties.

Radiofrequency Pitch Raising Surgery of Low Vocal Pitch Female that Results from Laryngeal Trauma (후두외상 후 발생한 저음발성 여자환자에서의 라디오전파를 이용한 음도상승 유도 치료 1예)

  • Kim, Min-Ho;Song, Ki-Jae;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.1
    • /
    • pp.56-59
    • /
    • 2006
  • The factors involved in controlling the vocal pitch are the tension, the mass, the length of the vocal cords and the subglottic pressure. Vocal pitch can be elevated surgically by increasing the stiffness or reducing the vibrating mass of the vocal cords. Recently, we experienced a case of 25 year-old female whose vocal pitch was elevated with radiofrequency surgery of right vocal cord on suspension laryngoscopy. Elevation of vocal pitch(134.11 to 144.73) was noted two months after operation. So we report this case with review of literature.

  • PDF

Kinematical Differences of the Male Professional Golfers' 30 Yard Chip Shot and Pitch Shot Motion (남자프로골퍼의 30 야드 칩샷과 피치샷 동작의 운동학적 차이)

  • Pyun, Eun-Kyung;Park, Young-Hoon;Youm, Chang-Hong;Sun, Sheng;Seo, Kuk-Woong;Seo, Kook-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.177-185
    • /
    • 2007
  • Even though there were no clear definitions of the short game and short game distance, short game capability is crucial for a good golf score. Generally, chip shot and pitch shot are regarded as two principal components of the short game. Chip shot is a short, low trajectory shot played to the green or from trouble back into play. Pitch shot is a high trajectory shot of short length. Biomechanical studies were conducted usually to analyze full swing and putting motions. The purpose of the study was to reveal the kinematical differences between professional golfers' 30 yard $53^{\circ}wedge$ chip shot and $56^{\circ}wedge$ pitch shot motions. Fifteen male professional golfers were recruited for the study. Kinematical data were collected by the 60 Hz three-dimensional motion analysis system. Statistical comparisons were made by paired t-test, ANOVA, and Duncan of the SPSS 12.0K with the $\alpha$ value of .05. Results show that both the left hand and the ball were placed left of the center of the left and right foot at address. The left hand position of the chip shot was significantly left side of that of the pitch shot. But the ball position of the pitch shot was significantly right side of that of the chip shot. All body segments aligned to the left of the target line, open, at address. Except shoulder, there were no significant pelvis, knee, and feet alignment differences between chip shot and pitch shot. These differences at address seem for the ball height control. Pitch shot swing motions(the shoulder and pelvis rotation and the club head travel distance) were significantly bigger than those of the chip shot. Club head velocity of the pitch shot was significantly faster than that of the chip shot at the moment of impact. This was for the same shot length control with different lofted clubs. Swing motion differences seem mainly caused by the same shot length control with different ball height control.