A general and efficient algorithm is proposed for the analysis of the frictionless elastic contact problems. It utilizes a simplex-type algorithm with a modified entry rule and incoporates finite element method to obtain flexibility matrices. The algorithmic solution is compared with the Hertzian solution for the contact problem between two cylinders to prove its accuracy and the contact problem between pin and piston rod is solved and compared with the numerical results of Frankavilla and Zienkiewicz to demonstrate the generality and effectiveness of the suggested algorithm. The contact problem between mating involute gear teeth at the worst load position is considered. The computed contact stress is smaller than the result of Hertz's theory applied to the contact between two kinematically equivalent discs and the contact area is larger than that of Hertz's theory.
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2013.10a
/
pp.792-796
/
2013
A practical process to optimize engine mounts on construction equipment is presented in this research. Transmitted force from the engine is estimated by using stiffness of the mount rubber which varies with frequency, amplitude and pre-load, and by the engine excitation force that comes from piston mass and gas pressure and so on. The transmitted force is measured through TPA(Transfer Path Analysis) and is then compared with the estimated force. The optimum mount position and stiffness are solved using MATLAB. The result shows the improvement on engine mount vibration.
Journal of Advanced Marine Engineering and Technology
/
v.32
no.3
/
pp.430-436
/
2008
Recently, there are many cases to use a ship's engine performance analyzer(SEPA) to measure pressure in cylinder and top dead center(TDC) of piston of engine, and analyze its performance such as fuel injection time and horsepower as well as wear of piston ring. But, SEPA needs TDC pulses($T(1){\sim}T(n)$) generated when pistons of engine are located to the TDC position ($TDC(1){\sim}TDC(n)$), these pulses are gathered from sensors connected to gear wheel of the propeller shaft in the remote distance from the measurement point. Therefore, operators need a long wire cable(WRC) to TDC detecting sensor to get these pulses, but this method is a very uncomfortable and expensive in case of installation, and it might decrease user's purchase desire. In this paper, we design and fabricate a small and inexpensive MODEM cable(M0C) so that it may be available to transmit TDC pulse generated from sensor in propeller shaft through existing power line. We also verify the facts that this MOC can be applied to SEPA and the effectiveness of the system through the experiments.
Journal of the Korean Institute of Intelligent Systems
/
v.20
no.1
/
pp.109-115
/
2010
A main technology of opening and closing a sluice gate is accurate synchronous and position control for the two cylinders when they are moving with the sluice gate together over 10[m]. Since the supply flow and supply pressure of cylinders are not constant and a nonlinear friction force of the piston in cylinders exists, a difference will be made between the displacement of two cylinders. This difference causes the sluice gate to deform and abrade, and even it may be out of order. In order to solve this problem we design two kinds of fuzzy PI controllers. The former is for a position control of two cylinders, the latter is for their synchronous control. We show some simulation results compare the performance of fuzzy PI controller to the conventional PID controller.
Journal of the Korean Society of Fisheries and Ocean Technology
/
v.23
no.2
/
pp.86-94
/
1987
In order to examine the flow motion in a combustion chamber of a motored diesel engine, the variation of instantaneous are velocity at a fixed point in combustion chamber was measured by the constant temperature hot wire anemometer, varing engine speed, shroud shape and shroud position. The results are summerized as follows: 1. The variation of air velocity in a combustion chamber is closely related with the valve timing and piston velocity. 2. The air velocity in the cylinder at suction stroke is being increased and maximized at 60$^{\circ}$ ABDC in compression stroke and then decreased at the e.v.o. in expansion stroke. 3. The mean velocity using shroud valve was less than no shroud valve. However the turbulent intensity using shroud valve was larger than no shroud valve. 4. The turbulent intensity with 90$^{\circ}$shroud valve was larger than that of 120$^{\circ}$shroud valve, and 90$^{\circ}$shroud valve at 180$^{\circ}$shroud position had the largest turbulent intensity.
Journal of the Korean Society of Fisheries and Ocean Technology
/
v.23
no.2
/
pp.40-40
/
1987
In order to examine the flow motion in a combustion chamber of a motored diesel engine, the variation of instantaneous are velocity at a fixed point in combustion chamber was measured by the constant temperature hot wire anemometer, varing engine speed, shroud shape and shroud position. The results are summerized as follows: 1. The variation of air velocity in a combustion chamber is closely related with the valve timing and piston velocity. 2. The air velocity in the cylinder at suction stroke is being increased and maximized at 60° ABDC in compression stroke and then decreased at the e.v.o. in expansion stroke. 3. The mean velocity using shroud valve was less than no shroud valve. However the turbulent intensity using shroud valve was larger than no shroud valve. 4. The turbulent intensity with 90°shroud valve was larger than that of 120°shroud valve, and 90°shroud valve at 180°shroud position had the largest turbulent intensity.
When a high-speed train passes an underground station, large pressure waves are generated due to the piston effect. These pressure waves can cause the problems of vibration and noise as well as the ear discomfort of passengers at the underground station. This work numerically analyzed the pressure wave generation and propagation in an high-speed railway underground station, and the optimal location for vent shafts was studied to improve the passenger comfort by reducing the magnitude of the pressure wave and its rate of change. The evolution of pressure field in the underground station was calculated using a CFD(Computational Fluid Dynamics) software(Fluent), where the axis-symmetric two-dimensional model verified by Wu was used. And this study is applied to modelling of the underground station and the tunnel from Daegok station A-line of GTX(Great Train Express). From the result, we can have a conclusion that the role of vent shafts respectively were different according to the position in and out the underground station. Also Vent shaft in the underground station widely reduced pressure magnitude. And vent shaft out underground station reduced initial pressure peak value. Double vent shafts installed at tunnel toward station entrance and inside of the tunnel are the most efficient to reduce pressure. and pressure reduction increases according to the number of vent shaft.
Transactions of the Korean Society of Automotive Engineers
/
v.14
no.6
/
pp.73-81
/
2006
A commercial diesel engine was converted into a dedicated natural gas engine to reduce the exhaust emissions in a retrofit of a diesel-fueled vehicle. The cylinder head and piston were remodeled into engine parts suited for a spark ignition engine using natural gas. The remodeling of the combustion chamber changed the compression ratio from 21.5 to 10.5. A multi-point port injection(MPI) system for a dedicated natural gas engine was also adopted to increase the engine power and torque through improved volumetric efficiency, to allow a rapid engine response to changes in throttle position, and to control the precise equivalence ratio during cold-start and engine warm-up. The performance and exhaust emissions of the retrofitted natural gas engine after remodeling a diesel engine are investigated. The emissions of the retrofitted natural gas engine were low enough to satisfy the limits for a transitional low emission vehicle(TLEV) in Korea. We concluded that a diesel engine can be effectively converted into a dedicated natural gas engine without any deterioration in engine performance or exhaust emissions.
Journal of Advanced Marine Engineering and Technology
/
v.5
no.1
/
pp.12-19
/
1981
As the fuel oil cost covers from 45% to 60% of the total expenditure for fishing boat operation, the energy saving is now an urgent problem to be taken a countermeasure for engineers, manufacturers or specialists engaging in this field. Undertaking a second-hand engine of the trainging ship, the author made several reconstructions to restore its performances. By inserting foot linears of connecting rods the compression ratio was increased and by adjusting both the fuel injection timing and the cooling water outlet temperature, its thermal efficiency was improved. The results of the experimental operation were summarized as follows. 1. By raising the piston top position 0.75mm more than the value of the operating manual, the compression pressure increased 1.3 kg/$cm^2$ and the maximum pressure did 3.4 kg/$cm^2$ at 75% load. 2. At 75% load, the difference of the maximum pressure between each cylinder was decreased from 2.4 kg/$cm^2$ to 1.8 kg/$cm^2$. 3. The fuel consumption was decreased about 8 g/ps.h at 75% load, and about 5.3 g/ps.h at 85% load. 4. The brake thermal efficiency was improved about 1.5% at 75% load and 0.9% at 85% load.
Transactions of the Korean Society of Automotive Engineers
/
v.12
no.3
/
pp.59-65
/
2004
In this paper a numerical study was performed for the effect of the wall curvature on the behaviors of fuel sprays impinging on the concave Surface. Actually, in the real diesel engines, a piston head has a curved shape for the purpose of the controlling the movement of fuel droplets and the mixture formation. For past decades, although many experimental and numerical works had been performed on the spray/wall impingement phenomena, the curvature effect of impinged wall was rarely investigated. The wall curvature affects on the behaviors of the secondary droplets generated by impingement and the concave wall obstructs the droplets to advance from the impinging site to outward. In present study, the simulation code was validated for the flat surface case and three cases of the different curvature were calculated and compared with the flat surface case for several parameters, such as the spray radius, the spray height and the position of vortex center of gas phase. The simulation results showed that the radial advance of the wall spray and the vortex is decreased with increasing the curvature. It was concluded that the curvature of the impinged wall significantly affects the behaviors of both the gas-phase and the droplet-phase.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.