• 제목/요약/키워드: pipe diameter

검색결과 800건 처리시간 0.027초

V8형 디젤엔진의 성능에 미치는 분사계의 영향에 관한 연구 (A Study on Effects of Fuel Injection System on the Performance in a V8-Type Diesel Engine)

  • 박병학
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.248-256
    • /
    • 1998
  • The effects of fuel injection system on the performance in a V8-type diesel engine was stuided in this paper. Fuel injection system is important factor which influence the engine performance and exhaust emission bcasuse the properties in the injected fuel depend on the atomization characteristics. In this study using diesel engine of 17.7:1 compression ration the engine performance and exhaust emission are measured experimentally according to 1000, 1400, 2200rpm in the full-load conditions. The chosen parameters for the major system are such diameter shape of combustion chamber and intake system. The results are as follows: As the nozzle hole diameter and injection angle become smaller and as the injection timing gets advanced the fuel consumption and concentration of smoke are decreasing whereas concentration of $NO_{x}$ is increasing. Andconcentration of $NO_{x}$ is increasing in accordance with the increase of injection pipe diameter and nozzle protrusion. Also it is shown that re-entrant type combustion chamber is more effective than that of toroidal type in the improvement of $NO_{x}$ reduction.

  • PDF

나선형 파형강관에서의 유동특성 및 압력강하 예측 (Prediction of Flow Behavior and Pressure Drop of Spirally Corrugated Steel Pipe)

  • 박종학
    • 한국전산유체공학회지
    • /
    • 제9권2호
    • /
    • pp.18-22
    • /
    • 2004
  • Numerical investigation has been conducted to figure out flow behavior and pressure drop characteristics of spirally corrugated steel pipe which is widely used in civil, industrial and agricultural field owing to many advantages such as good corrosion resistance and durability, strength, easy and quick installation. Also the poly-ethylene coating spirally corrugated steel pipe has the long life under condition of sea water immerged. In the present study, flow behavior in the spirally corrugated pipe and influence of P/d/sub h/(ratio of wave pitch to hydraulic diameter) to pressure drop are investigated by CFD with various Reynolds number. And also friction factor is estimated by pressure drop obtained by flow analysis. According to computation results, the flow runs spirally up and down along the spiral corrugation in the vicinity of wall, but the effect of spiral corrugation disappears in core region of pipe. As P/d/sub h/ becomes small, more pressure drop occurs in spirally corrugated Pipe. Besides, friction factor augmentation becomes much larger as Re increases. In case of p/d/sub h/=0.38, Pressure drop and friction factor of spirally corrugated pipe are about four times larger than smooth pipe at Re: 1.46×10/sup 6/.

오비탈 성형을 이용한 피팅 파이프 플랜지 공정연구 (Fitting Pipe Flange Process Research Using Orbital Forming)

  • 김태걸;박준홍;박영철
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.57-62
    • /
    • 2015
  • A large variety of pipe flanges are required in the marine and construction industry. Pipe flanges are usually welded or screwed to the pipe end and are connected with bolts. This approach is very simple and has been widely used for a long time; however, it results in high development costs and low productivity, and the products made through this approach usually have safety problems in the welding area. In this research, a new approach for forming pipe flanges based on cold forging and the floating die concept is presented. This innovative approach increases the effectiveness of the material usage and saves time and costs compared with the conventional welding method. To ensure the dimensional accuracy of the final product, finite element analysis (FEA) was carried out to simulate the process of cold forging, and orthogonal experiment methods were used to investigate the influence of four manufacturing factors (stroke of distance, pin die angle, forming of pipe diameter, and speed of the die) and predict the best combination of them. The manufacturing factors were obtained through numerical and experimental studies, which show that the approach is very useful and effective for the forming of pipe flanges and could be widely used in the future.

시설원예용 플라스틱 하우스의 태풍피해에 관한 연구 (A Study on the Typhoon Disaster of Greenhouse)

  • 윤용철;서원명;윤충섭
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.167-174
    • /
    • 1995
  • This study was carried out to find a way of improving the windproof capability of greenhouse foundations. Generally, greenhouses are often collapsed due to the strong winds, because they are very light weight structures. In such a critical situations, the foundations are very often subjected to uplift and vibration at the same time. This paper describes both the wind disaster of greenhouses by the typhoon FAEY and the uplift resistance of greenhouse foundations. Followings are the results obtained from this study ; Judging from the view point of year round cultural aspects, it is recommended that some measures be taken for the preventions of greenhouse film ruptures because greenhouse structural damages are found to be directly associated with the local rupture of cover film. In the case of surveyed area, movable pipe-houses or pipe-houses of 1-2W type were found to be completely destroyed when the maximum instantaneous wind velocity was over 30m/sec or so. In the case of movable pipe-houses, the uplift resistance of greenhouse was expected to increase with the increase of pipe diameter and/or the embedment pipe length. But at present situations there is a limitation in raising the uplift resistance of movable pipe-house, because pipe diameters as well as pipe lengths customarily selected by farmers are quite a much limited.

  • PDF

상계법과 유한요소법을 이용한 확관금형 설계 (Design of Pipe Expanding Die by Upper Bound Analysis and Finite Element Method)

  • 조용일;김승환;추연근;조해용
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.98-104
    • /
    • 2020
  • Pipe expansion involves various methods to enlarge the diameter of the pipes with the use of a mandrel or punch placed inside the pipe. In this study, the upper bound method was used to analyze the pipe expanding process as well as design a die. A kinematically admissible velocity field was derived for the upper bound analysis with the occurrence of pipe thinning during the expansion factored in. The analysis confirms that a semi-cone angle of the punch between 15ween pip is most advantageous for pipe expansion. The results of the upper bound analysis, which were also consistent with those of the FEM, can be useful for the design of a pipe expansion die.

줌카메라를 활용한 빗물받이 연결관의 도로함몰 리스크 분석 (Risk analysis of road cave-in of storm sewer lateral using zoom camera)

  • 한상종;황환국
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.681-690
    • /
    • 2014
  • It is known that sewer problems are the major causes of road cave-in. The objective of this study is to analyze the risk of road cave-in due to storm sewer laterals. We investigated 174 storm sewer laterals using a zoom camera at O-dong area in Seoul. The causes of road cave-in were classified into five cases: breakage of rigid pipe, deformation of flexible pipe, out of pipeline alignment, changing pipe material or changing pipe diameter, and a poor linkage between lateral and sewer. In addition, all defects were sorted into five grades based on the severity rating at storm sewer laterals. In this study, the most fragile pipe materials were found to be concrete pipe and polyethylene pipe, which recorded 2.3 and 1.69 defect rates. With regard to the causes of road cave-in, deformation of flexible pipe has a large influence on road cave-in at present. On a long-term basis, the two causes, out of pipeline alignment and a poor linkage between lateral and sewer, could have more influence on road cave-in.

수직형 라이트파이프의 채광성능에 관한 예비평가 (Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System)

  • 신혜미;박훈;김정태
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

태양열 집열기용 히트파이프의 열전달 특성에 대한 해석 (Analysis of the Heat Transport Capacity of a Axial Grooved Heat Pipe for Solar Collector)

  • 정경택;배찬효;서정세;김병기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.317-322
    • /
    • 2005
  • This study is aimed to analyze the effects of heat pipe shape on the heat transfer in solar collector with a axial grooved heat pipe. In the design of a heat pipe. two of the most important criteria to be met are the operating temperature range and the maximum heat transport capacity, When the operating temperature range is known and the working fluid has been selected, the maximum heat transport capacity depends strongly on capillary pressure and liquid flow. The heat transport capacity of the heat pipe will depend on the geometry of the heat pipe, the wick structure. the vapor channel shape. groove number. cooling temperature. condenser length and pipe diameter. So various shapes are used for mathematical models of two-phase flow in grooved heat pipe. From the results. the adequate groove shape and scale are presented by considering the heat transport and capillary limitation.

  • PDF

소결 코팅 파이프의 열전달 성능에 관한 연구 (A Study on the Heat Transfer Performances in Sintered Pipes)

  • 박기호;;김성일;정대헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.436-439
    • /
    • 2008
  • This paper is to research the heat transfer performance of the sintered pipe. Recently, oil prices is to be 127 $ per barrel, we expect higher costs this summer. We promote alternative fuels, after oil and gasoline prices reached record highs. The governments have made efforts to avoid future crisis by continuing the move toward renewable energy and energy saving. In this paper, we have fabricated a sintered pipe, the heat transfer performance of sintered pipe is achieved experimentally. The pipe is copper tube of outer diameter of 15.88 mm, the length of the pipe is 800 mm. Based on the experimental results, it is shown the overall heat transfer coefficient of sintered pipe is increased as compared with that of a straight pipe, is equal as compared with that of a spiral pipe. The overall heat transfer coefficient was $0.075{\sim}0.09\;kW/^{\circ}C$

  • PDF

지반 조건을 고려한 최적강관두께의 결정 (The Determination of Optimal Steel Pipe Wall Thickness Considering Ground Condition)

  • 박재성;오병동;이호진
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.11-15
    • /
    • 2008
  • 대구경 상수도 관로는 제작 및 경제성 요인에 의해 주로 강관을 사용해 오고 있다. 상수도시설기준(건교부, 1992)에 강관두께를 결정하는 기준을 제시하고 있다. 그러나, 이 기준에는 강관 두께를 결정하는 체계적인 기준이 없다. 그래서, 매설관로에는 적용이 부적합한 Stewart 공식을 적용하여 강관두께를 결정해 왔다. 개정된 상수도시설기준(환경부, 1997) 에 부합되도록 지반여건과 각종응력을 고려하여 강관두께를 산정하였다. 그 결과를 기존의 방법에 의해 산정된 결과와 비교 검토한 후 최적 강관두께를 결정하는 방법을 제시하였다.

  • PDF