• Title/Summary/Keyword: pinhole

Search Result 208, Processing Time 0.024 seconds

360-degree Viewable Cylindrical Integral Imaging System Using Electroluminescent Films

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1254-1257
    • /
    • 2009
  • A 360-degree viewable three-dimensional display based on integral imaging is proposed. The cylindrically arranged point light source array which is generated by electroluminescent (EL) pinhole film reconstructs 360-degree viewable virtual 3D image at the center of the cylinder. In this paper, the principle of operation and experimental results are presented.

  • PDF

360-degree Viewable Cylindrical Integral Imaging System Using Electroluminescent Films

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1330-1333
    • /
    • 2009
  • A 360-degree viewable three-dimensional display based on integral imaging is proposed. The cylindrically arranged point light source array which is generated by electroluminescent (EL) pinhole film reconstructs 360-degree viewable virtual 3D image at the center of the cylinder. In this paper, the principle of operation and experimental results are presented.

  • PDF

Pinhole Defect Detection Algorithm of Tarpaulin using Morphology (모폴로지를 이용한 타포린의 함침 검출 알고리즘)

  • Oh, Choon-Suk;Lee, Hyun-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.907-911
    • /
    • 2000
  • 타포린 제조 공정에서 함침의 발생 여부를 검사하는 것은 동 업계의 중요한 문제이다. 본 논문에서는 모폴로지를 사용한 함침 검사를 수행하였다. 모폴로지를 이용한 변환들 중의 하나인 Top hat 변환을 사용하였으며, 이 변환은 완만하게 불균일한 배경에서 급격한 변화를 가지는 물체를 추출하는데 탁월한 성능을 가진다. 이를 사용한 결과, 250dpi 영상에서 0.2mm 이상 크기의 함침을 검출할 수 있었다.

  • PDF

Effect of fringe divergence in fluid acceleration measurement using LDA (레이저 도플러 원리를 이용한 유체 가속도 측정)

  • Chun, Se-Jong;Nobach, Holger;Tropea, Cam;Sung, Hyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1546-1551
    • /
    • 2004
  • The laser Doppler technique is well-established as a velocity measurement technique of high precision for flow velocity. Recently, the laser Doppler technique has also been used to measure acceleration of fluid particles. Acceleration is interesting from a fluid mechanics point of view, since the Navier Stokes equations, specifically the left-hand-side, are formulated in terms of fluid acceleration. Further, there are several avenues to estimating the dissipation rate using the acceleration. However such measurements place additional demands on the design of the optical system; in particular fringe non-uniformity must be held below about 0.0001 to avoid systematic errors. Relations expressing fringe divergence as a function of the optical parameters of the system have been given in the literature; however, direct use of these formulae to minimize fringe divergence lead either to very large measurement volumes or to extremely high intersection angles. This dilemma can be resolved by using an off-axis receiving arrangement, in which the measurement volume is truncated by a pinhole in front of the detection plane. In the present study an optical design study is performed for optimizing laser Doppler systems for fluid acceleration measurements. This is followed by laboratory validation using a round free jet and a stagnation flow, two flows in which either fluid acceleration has been previously measured or in which the acceleration is known analytically. A 90 degree off-axis receiving angle is used with a pinhole or a slit.

  • PDF

Pinhole Phenomena in the External Electrode Fluorescent Lamps (외부전극 헝광램프의 핀홀 현상)

  • Gill, Doh-H.;Kim, Sang-B.;Song, Hyuk-S.;Yu, Dong-G.;Lee, Sang-H.;Pak, Min-Sun;Kang, June-Gill;Cho, Guang-Sup;Cho, Mee-R.;Hwang, Myung-G.;Kim, Young-Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.266-272
    • /
    • 2006
  • Application of power higher than the optimum operation value to an external electrode fluorescent lamps(EEFL) leads to the formation of small holes, called pinholes, which subsequently leads to lamp failure. The pinholes come from the insulating breakdown of the capacitor which is the dielectric layer between an external electrode and glass tube. The power of insulation breakdown is proportional to the electric power applied to the lamp. When a lamp current is low in the glass tube of dielectric constant K, the dielectric field strength of pinholes is about 3K kV/mm. The field strength of insulation breakdown decreases as the lamp current increases.

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Super Multi-view Display Method using Pin-hole Array (핀홀어레이를 이용한 슈퍼 멀티-뷰 3D 디스플레이)

  • Byeon, Jin-A;Kwon, Ki-Chul;Erdenebat, Munkh-Uchral;Park, Jae-Hyeung;Kim, Sung-Kyu;Kim, Jong-Jae;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • In this paper a Super Multi-view display method using a pinhole array with full parallax was proposed. The proposed method was simulated and its parameters analyzed. Also, the distribution and irradiance of light through each pinhole on the retina receiver, according to the change of crystalline lens focal length, were found by simulation. As a result, an image free of blurring was obtained while the crystalline lens focused on the depth plane of the three-dimensional image created by the imaging lens.

Failure Analysis on Localized Corrosion of Heat Transport Pipe in District Heating System (지역난방 열수송관 국부 부식 파손 분석)

  • Kim, You Sub;Chae, Hobyung;Kim, Woo Cheol;Jeong, Joon Cheol;Kim, Heesan;Kim, Jung-Gu;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.122-130
    • /
    • 2020
  • In this study, a corrosion failure analysis of a heat transport pipe was conducted, as the result of a pinhole leak. Interestingly, the corrosion damage occurred externally in the pipeline, resulting in severe thickness reduction near the seam line. Also, while a stable magnetite protective film formed on the inner surface, the manganese oxide formation occurred only on the outer surface. The interior and exterior of the pipe were composed of ferrite and pearlite. The large manganese sulfide and alumina inclusions were found near the seam line. In addition, the manganese sulfide inclusions resulted in grooving corrosion, which progressed in the seam line leading to the reduction in the thickness, followed by the exposure of the alumina in the matrix to the outer surface. To note, the corrosion was accelerated by pits generated from the boundaries separating the inclusions from the matrix, which resulted in pinhole leaks and water loss.

Target Latitude and Longitude Detection Using UAV Rotation Angle (UAV의 회전각을 이용한 목표물 위경도 탐지 방법)

  • Shin, Kwang-Seong;Jung, Nyum;Youm, Sungkwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.107-112
    • /
    • 2020
  • Recently, as the field of use of drones is diversified, it is actively used not only for surveying but also for search and rescue work. In these applications it is very important to know the location of the target or the location of the UAV. This paper proposes a target detection method using images taken from drones. The proposed method calculates the latitude and longitude information of the target by finding the location of the target by comparing it with the image to find the image taken by the drone. The exact latitude and longitude information of the target is calculated by calculating the actual distance corresponding to the distance of the image image using the characteristics of the pinhole camera. The proposed method through the actual experiment confirmed that the latitude and longitude of the target was accurately identified.