• Title/Summary/Keyword: pilot test site

Search Result 106, Processing Time 0.024 seconds

Pilot Test of Grid-Type Underground Space Considering Underground Complex Plant Operation (지하 복합플랜트 운영 중 확장을 고려한 격자형 지하공간 파일럿 테스트)

  • Chulho Lee
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.472-482
    • /
    • 2023
  • The grid-type or room-and-pillar method is applied for the purpose of mining horizontally buried minerals. In this study, design and pilot test were performed to apply the room-and-pillar method which uses natural rock as a rock pillar to the construction of underground space. The area where the pilot test was conducted was in stone mine and had good rock conditions with an appropriate depth (about 30 m) to apply the pilot test. The pilot test site was selected by reviewing accessibility and ground conditions and then site construction was performed through detailed ground investigation and design. The pilot test was designed with a column shape of 8×8 m and a cross-section of 8×12 m. The blasting pattern was determined through test blasting at the site, and blasting of 3 m excavation with 89 holes was performed. Through field observations, the average width of 12.5 m and the average height of 8.3 m were measured. Therefore, it is possible to proceed similar to the cross-sectional shape considered in the design.

Applicability of Dynamic Compact Pilot Test on Waste Landfill (폐기물 매립장에서 동다짐공법의 적용성에 관한 연구)

  • 천병식;임병수;김명진
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.418-425
    • /
    • 2000
  • In this study, the evaluation for utilization of waste landfill was performed by field test to use waste landfill as construction site(Nangido in Seoul). The site where dynamic compaction test was carried out was divided by 4 yards. Yard 1, 2 were not eliminated widening of cover soil and Yard 3, 4 were eliminated it. Dynamic Compaction Pilot Test was carried out by the 15ton heavy tamper with drop height of 20m in Yard 1, 3 and with drop height of 15m in Yard 2, 4 We evaluated the compaction ability, optimum compaction number and noiseㆍvibration through field test, monitoring. To make use of waste landfill as a construction site, The dynamic compaction method is suitable for using in waste landfill as a construction site among the ground improvement methods.

  • PDF

Soil Improvement using Vertical Natural Fiber Drains (연직천연섬유배수재를 이용한 연약지반 개량)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.4
    • /
    • pp.37-45
    • /
    • 2008
  • A pilot test using environmentally friendly drains, was carried out to evaluate their applicability potential in the field. The pilot test site was divided into 5 different areas, with several combinations of vertical and horizontal drains installed for evaluation. Conventional natural fiber drains (FDB), new developed straw drain board (SDB) and plastic drain board (PDB) were used as vertical drains, while sand and fiber mats were used as horizontal drains. Surface settlement rates and excess pore pressure generation/dissipation tendency of PDB and FDB are almost identical except those of SDB. Cone tip resistance obtained from cone penetration test measured at the end of 1st consolidation stage for upper soft layer definitely increased irrespective of types of vertical drains. The monitoring and site investigation test data obtained at the pilot test site prove the vertical natural fiber drains can be used as substitutes of conventional plastic and sand material.

  • PDF

Pilot Scale Feasibility Test of In-situ Soil Flushing by using 'Tween 80' Solution at Low Concentration for the Xylene Contaminated Site

  • Um, Jae-Yeon;Lee, Gyusang;Song, Sung-Ho;Hong, Sunwook;Lee, Minhee
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.38-47
    • /
    • 2013
  • This study was performed to identify the optimal operating conditions and to evaluate the xylene removal efficiency, applying in-situ soil flushing with the low concentrated solution of 'Tween 80' at the xylene contaminated site. The pilot scale test site ($5m{\times}5m{\times}3m$), was mainly composed of 'sandy loam', with the average hydraulic conductivity of $9.1{\times}10^{-4}cm\;s^{-1}$. The average xylene concentration of the site was 42.1 mg $kg^{-1}$, which was more than 2.5 times higher than Korea soil pollution warning limit (15 mg $kg^{-1}$). For the soil flushing, 7,800 L of 0.1~0.2% surfactant solution was injected into three injection wells at the average injection time of 9 hr $d^{-1}$ for 10 days, followed by the additional only groundwater injection of 6,000 L. The same amount of the effluent solution was extracted from three extraction wells. From the analysis for xylene concentration of all effluent at 3 extraction wells, total 166 g of xylene was removed by in-situ surfactant flushing. Even though the residual xylene concentrations of 7 soil sampling locations in the test site were different due to the soil heterogeneity, from the comparison of xylene concentration at 7 locations before/after the feasibility test, 53.9% of the initial xylene in the site was removed from three extraction wells (mainly Ext-N and Ext-M well). The results showed that the in-situ soil flushing by using low concentrated 'Tween 80' solution had a great potential to remediate the xylene contaminated site.

Effective Utilization of Waste Landfill by Dynamic Compaction Pilot Test (동다짐에 의한 폐기물 매립장의 유효활용에 관한 연구)

  • Chun, Byung-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.71-78
    • /
    • 2000
  • In this study, the evaluation for effective utilization of waste landfill was performed by field test to use waste landfill as construction site(Nangido in Seoul). This site had been formed by dredging the household waste, building debris and industrial waste for fifteen years(78'3~93'3). The site where dynamic compaction test was divided by 4 yards. Yard-1, 2 were not eliminated widening of cover soil and Yard-3, 4 were eliminated it. Dynamic Compaction Pilot Test was carried out by the 15ton heavy tamper with drop height of 20m in Yard-1, 3 and with drop height of 15m in Yard-2, 4. We evaluated the compaction efficiency, optimum compaction number and noise vibration through field test, monitoring. As a result, if the countermeasures against vibration and noise by the method utilize, the dynamic compaction method is suitable for using in waste landfill as a construction site among the ground improvement method.

  • PDF

A Site Application of the Revealing High Early Strength Concrete (조기강도 발현형 콘크리트의 현장 적용성 연구)

  • Kim Gyu Dong;Lee Seung Hoon;Sohn Yu Shin;Kim Han Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.560-563
    • /
    • 2004
  • This study reports the site application of concrete using AE Water Reducing Agent of Early-Strength Type. According to the lab test results, we have made plans of batch plant pilot test, and we have analyzed the erly aged compressive strength and workability of the concrete. We applied the early-strength development concrete to the construction site. We accomplished the slump test in order to evaluate the workablity and air contents, we made site curing mold to evaluate the early strength of members. As a result, we judgeed the superior property of early strength development of the concrete, and thought that we can reduce the time of form stripping more $40\%$ than ordinary strength concrete. We thought that we can reduce the term of works and finally we can accomplish the economical construction.

  • PDF

A Fundermental Study on Stabilization in Municipal Waste Landfill Site (도시폐기물 매립지의 안정화에 관한 기초연구)

  • 김은호;김순호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • The investigation was carried out to analyze the generation and the composition of landfill gas generated from inserted pipe wells into the underground by boring operation and also study the undecomposed waste characteristics by open-cut test at S. waste landfill site in Pusan city. Pilot test was conducted for stabilization. The experimental results from this study were summerized as follows. ; Since COD matter was easuer decomposed than COD matter for continuously biological stabilization in underground, it seemed that BOD and CO $D_{Mn}$ were in the range of 854~4,813mg/$\ell$ and 1,156~6,977mg/$\ell$ and their ratio were generally as high as 0.55~0.74. As C $H_4$ compositions of generated gas were measured in the range of 37.36~60.1%, we could know that C $H_4$ gas was actively generated. Organic matters by open-cut test averaged 13.4~16.6% at each landfill layer, and considering rate of combustible compositions(36.2~66.5%) for landfilling wastes, they have been actively decomposed. The measured and theoretical values of generated gas in waste landfill site were almost similar to C $H_4$ 50.0% and 53.4%, $CO_2$ 39.63% and 45.24%, and after 0.5$^{\circ}C$ with heavy depth and long landfill period. From the results of pilot test for stabilization, after 180 days organic matters were actively decomposed beyond 2.2 times in facultative aerobic lystimeter(B) to exsiting anaerobic lysimeter(A). Therefore, it seemed that landfill site was of benefical to the conversion of facultative aerobic for stabilization.

  • PDF

A Study on Skin Friction Estimation of Drilled Shaft Socketed in Weathered Granite by IGM's Theory (화강풍화암에 근입된 현장타설말뚝의 주면마찰력 산정에 대한 IGM 이론의 적용)

  • Hong, Soon Taek;Lee, Jong In;Shin, Young Wan;Lee, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6C
    • /
    • pp.241-250
    • /
    • 2011
  • The design method of IGM proposed by FHWA to predict bearing capacities of drilled shaft socketed in weathered granite has been used generally. In this study, site investigations were performed in a pilot test site, and disturbance and roughness were measured. Geotechnical properties were assorted as cohesive material and undisturbed and smooth surface. A simple relationship was proposed to predict unconfined strength ($q_u$) of weathered granite using static load test results, load transfer test results and N values. It was confirmed that the design method to estimate bearing capacities of drilled shaft could improve IGM's theory for weathered granite from this research.

Settlement Restraint of Soft Ground by Low Slump Mortar Injection (저유동설 몰탈주입에 의한 연약지반의 침하억제 효과)

  • 천병식;여유현;정영교
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.53-67
    • /
    • 2001
  • In this study the pilot test of CGS as injection method by low slump mortar was performed and the results were analyzed in order to find out the application of this method and effect of settlement restraint. The site far pilot test is adjacent to apartments supported by pile foundations. Sand drain method was performed previously as countermeasures against settlement, but settlement occur continuously because this ground is very soft. Site investigations such as SPT, DCPT and vane shear test were performed to determine the characteristics of ground improvement. Field measurements and FDM analysis were performed on purpose to find out the displacement of ground during injection works. From the results of this study, CGS method can be optimized by the control of diagram, space, depth, injection material, and injection pressure. CGS improved soft ground compositely by the bearing effect of CGS columns and reinforcement of adjacent ground. Considering that increase of N value is about 2.1, CGS can be considered as an effective method to increase the bearing capacity as well as to stop the settlement of soft ground. It is also expected to be economic and effective in improvement of ground when it is used in applicable sites.

  • PDF

A study on the dye wastewater treatment by Fenton oxidation process (Fenton 산화공법을 적용한 염색폐수처리 연구)

  • Ahn, June-Shu;Park, Tae-Sool;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4274-4282
    • /
    • 2011
  • In this study, Fenton reaction was studied for the possibility of applying as advanced treatment and its optimal condition for the removal of refractory organics from the dye wastewater. Fenton reaction was applied to remove refractory organics after the bio-treatment (secondary treatment) inside test laboratory and on-site pilot plant. Wastewater from the secondary treatment was used and its $COD_{Mn}$ was measured as 30~50mg/L. After the Fenton reaction, the optimal condition was found as pH 3~3.5, reaction time 2~2.5hr, chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was 3 : 1. When chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was at its optimal, amount of sludge volume ($SV_{2hr}$) was 21~28%. With pilot plant test, removal rate was heavily influenced by the hydraulic retention time(HRT), and optimum value of HRT was 2.0 hr. When pilot plant($2m^3/d$) was placed on-site and operated continuously, it showed steady and fairly good treatment of COD where COD removal rate was 60~70%, treated water showed below 20mg/L.