• 제목/요약/키워드: pile structural capacity

검색결과 76건 처리시간 0.025초

Settlement analysis of pile cap with normal and under-reamed piles

  • Kumar, Madisetti Pavan;Raju, P. Markandeya;Jasmine, G. Vincent;Aditya, Mantini
    • Computers and Concrete
    • /
    • 제25권6호
    • /
    • pp.525-535
    • /
    • 2020
  • The use of pile foundations has become more popular in recent years, as the combined action of the pile cap and the piles can increase the bearing capacity, reduce settlement, and the piles can be arranged so as to reduce differential deflection in the pile cap. Piles are relatively long, slender members that transmit foundation loads through soil strata of low bearing capacity to deeper soil or rock strata having a high bearing capacity. In this study analysis of pile cap with considering different parameters like depth of the pile cap, width and breadth of the pile cap, type of piles and different types of soil which affect the behaviour of pile cap foundation is carried out by using Finite Element Software ANSYS. For understanding the settlement behaviour of pile cap foundation, parametric studies have been carried out in four types of clay by varying pile cap dimensions with two types of piles namely normal and under-reamed piles for different group of piles. Furthermore, the analysis results of settlement and stress values for the pile cap with normal and under-reamed piles are compared. From the study it can be concluded that settlement values of pile cap with under-reamed pile are less than the settlements of pile cap with normal pile. It means that the ultimate load bearing capacity of pile cap with under-reamed piles are greater than the pile cap with normal piles.

비배토 현장타설 콘크리트 말뚝의 지지력 산정에 관한 연구 (Bearing capacity Calculation of Displacement in-situ Concrete Pile)

  • 박종배;박태순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 말뚝기초 학술발표회
    • /
    • pp.65-84
    • /
    • 2000
  • Europe and US which have more restrictive regulations than Korea about the noise and vibration during construction are using Auger-cast Pile to reduce the problem relating with noise and vibration. However Auger-cast Pile has problems like difficult quality control and low bearing capacity. In Europe, Displacement in-situ concrete Pile has been used to sove that problems since 1990s, and Korea has performed the test construction in 1997 and it has been used as the real structural foundation since 1998. Test and real construction results verified that the allowable capacity of the pile(diameter = 410mm) is between 70 and 100ton. Though De Beer & Van Imps design method utilizing CPT result is used to calculate the bearing capacity of the Displacement in-situ Pile, Korea is dependant upon the SPT as the sounding test, so design method utilizing SPT result is necessary to promote the application of the pile. To find out reasonable design method using SPT result, rearing capacity of the pile constructed in sand and clay in Korea was calculated using Meyerhof, SPT-CPT translation method, Nordlund, Douglas and DM-7 method, and the calculation results were compared to the load test result. Analysis result shows that SPT-CPT translation method is more reliable than others and economical design can be possible because it considers efficiently the friction capacity of Displacement in-situ Pile.

  • PDF

고강도 강관말뚝의 항타후 구조성능 분석 (Structural Capacity of High Strength Steel Pipe Pile After Pile Driving)

  • 나승민;유한규
    • 대한토목학회논문집
    • /
    • 제31권6C호
    • /
    • pp.251-258
    • /
    • 2011
  • 강관말뚝은 오랫동안 다양한 깊은 기초에 적용되어 왔으나 최근 강재가격의 상승으로 균질한 품질, 큰 강성, 용이한 시공 등의 장점에도 불구하고 기술자들이 자유롭게 적용 못하고 있다. 그러므로 강관말뚝으로 시공할 경우에는 초기 항타후 계획고 이상에서 절단된 강관을 재활용할 수 있다면 공사비를 절감하는데에 기여할 수 있다. 이러한 사유로 인하여 시공자들은 항타후 절단된 강관말뚝을 새롭게 시공할 말뚝과 함께 시공하고자 하나 명확한 정량적인 항타후 강관말뚝의 거동특성의 부재 및 재활용을 위한 적절한 대응방법과 기준의 부재로 인하여 말뚝의 건전도 문제, 문제 발생시의 대응방법 부재 등이 실제 현장에서 종종 발생하고 있다. 본 연구에서는 신규 강관말뚝과 사용자 하중 또는 극한 하중을 받은 강관말뚝에 대하여 현장에서 수행한 말뚝 동재하시험과 실내에서의 피로시험, 인장시험, 샤르피 충격시험을 실시하여 그 결과를 비교분석하였다. 시험결과로부터 허용응력 수준의 항타응력이 발생한 사용 하중조건에서는 항복강도의 변화가 2% 이하이며 최대 허용항타응력($0.9{\sigma}_y$)을 항타횟수가 3000회까지 받은 극한 하중조건에서는 항복강도의 변화가 5% 이하인 것을 확인할 수 있다. 또한 각 변수의 민감도를 확인하기 위하여 통계분석을 실시하였다. 모든 실험결과로부터 강관말뚝의 재활용 가능여부에 대한 판단 기준은 항복강도의 변화 보다는 오히려 샤르피충격에너지, 용접부에서의 강도변화 및 품질관리, 강관의 단면 변화, 항타후 강관의 국부좌굴에 기인하는 것을 확인할 수 있었다.

Lateral capacity of piles in layered soil: a simple approach

  • Mandal, Bikash;Roy, Rana;Dutta, Sekhar Chandra
    • Structural Engineering and Mechanics
    • /
    • 제44권5호
    • /
    • pp.571-584
    • /
    • 2012
  • Appropriate assessment of lateral capacity of pile foundation is known to be a complex problem involving soil-structure interaction. Having reviewed the available methods in brief, relative paucity of simple and rational technique to evaluate lateral capacity of pile in layered soil is identified. In this context, two efficient approaches for the assessment of lateral capacity of short pile embedded in bi-layer cohesive deposit is developed. It is presumed that the allowable lateral capacity of short pile is generally dictated by the permissible lateral displacement within which pile-soil system may be assumed to be elastic. The applicability of the scheme, depicted through illustration, is believed to be of ample help at least for practical purpose.

Large-scale pilot test study on bearing capacity of sea-crossing bridge main pier pile foundations

  • Zhang, Xuefeng;Li, Qingning;Ma, Ye;Zhang, Xiaojiang;Yang, Shizhao
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.201-212
    • /
    • 2014
  • Due to the sea-crossing bridge span is generally large and main pier pile foundations are located in deep water and carry large vertical load, sea-crossing bridge main pier pile foundations bearing mechanism and load deformation characteristics are still vague. Authors studied the vertical bearing properties of sea-crossing bridge main pier pile foundations through pilot load tests. Large tonnage load test of Qingdao Bay Bridge main pier pile program is designed by using per-stressed technique to optimize the design of anchor pile reaction beam system. Test results show that the design is feasible and effective. This method can directly test bearing capacity of main pier pile foundations, and analysis bearing behaviors from test results of sensors which embedded in the pile. Through test study the vertical bearing properties of main pier pile foundation and compared with the generally short pile, author summarized the main pier pile foundations vertical bearing capacity and the main problem of design and construction which need to pay attention, and provide a reliable basis and experience for sea-crossing bridge main pier pile foundations design and construction.

PHC파일과 CT형강을 합성한 합성형 벽체파일의 휨거동에 대한 연구 (A Study on Flexural Behavior of Composite PHC pile with CT Structural Steel)

  • 마호성;원정훈;조효상
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.233-243
    • /
    • 2012
  • 본 연구에서는 PHC(Pretensioned spun High strength Concrete)파일에 CT형강을 합성시킨 합성형 벽체파일을 실물 크기로 4개 제작한 후 휨 실험을 수행하여 합성형 벽체파일의 극한 강도와 합성작용 등의 구조 성능을 분석하였다. 합성형 벽체파일은 천공홀이 설치된 CT형강의 복부가 perfobond rib 전단연결재 역할을 하여 콘크리트와 CT형강을 합성시킨 구조물로써 CT형강의 플랜지를 이용하여 벽체파일과 버팀보 또는 상 하부 슬래브의 연결이 가능하므로 기능성과 구조적 성능이 동시에 향상된 구조이다. 모든 실험체의 파괴모드는 휨 파괴였으며, 극한강도는 설계기준에 따라 계산된 목표 설계값보다 큰 것으로 분석되어 개발된 합성형 벽체파일은 충분한 강도를 확보한 것으로 판단되었다. 또한 천공홀을 갖는 CT형강의 복부는 perfobond rib 전단연결재 역할을 적절히 수행할 수 있는 것으로 분석되었다.

철도하중을 고려한 기초구조물과 강관말뚝 연결부 거동에 관한 실험적 연구 (Experimental Study on the Connection between RC Footing and Steel Pile according to Rail loads)

  • 김정성;김대상;조국환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1607-1614
    • /
    • 2011
  • As the connection between spread footing and pile is very important structural connection, it acts as the inter-loading medium to transfer the rail loads applied by superstructure to ground through the body pile of foundation. The experimental study is the method how to reinforce the pile cap between steel pile and footing utilizing perfobond plate with protruding keys. It were experimented on the compression punching tests and bending moment tests against the vertical loading and horizontal loadings acting on head of steel tube pipe. As a result, the tension capacity of the perfobond plate exhibited the superior performance due to the interlocking or dowel effects by the sheared keys of perfobond plate, and there were showing the sufficient strength and ductile capacity against the bending moment of horizontal loading tests. Therefore, it is judged that "the embedded method of perfobond plate in pile cap and footing" which is utilizing the shear connection of perfobond plate with protruding keys has a sufficient structural stability enough to be replaced with the current specification of reinforced method of pile cap with vertically deformed rebar against the vertical compression loads and bending moments that are able to occur in the combination structure of steel pile and the footing foundation.

  • PDF

철근콘크리트 합성 H-Pile의 휨성능 (Flexural Capacity of RC Composited H-Pile)

  • 김민준;신근옥;정제평
    • 콘크리트학회논문집
    • /
    • 제28권5호
    • /
    • pp.563-570
    • /
    • 2016
  • 서로 다른 응력-변형률 구성관계를 갖는 2가지 이상의 재료로 구성된 합성구조부재의 사용이 크게 증가하고 있다. 본 연구에서는 철근 및 콘크리트로 보강한 합성 H-Pile의 휨성능을 평가하고자 8개의 실험체를 제작하여 휨실험을 실시하였다. 실험결과 합성H-Pile의 휨성능이 무보강 H-Pile보다 10~30%정도 크게 나타났고, 연성능력은 2배 이상, 에너지소산능력은 3배 이상 증가하였다. 한계상태해석 결과는 실험보다 보수적인 강도예측을 하였다.

An approach of seismic design for sheet pile retaining wall based on capacity spectrum method

  • Qu, Honglue;Li, Ruifeng;Hu, Huanguo;Jia, Hongyu;Zhang, Jianjing
    • Geomechanics and Engineering
    • /
    • 제11권2호
    • /
    • pp.309-323
    • /
    • 2016
  • As the forefront of structural design method, capacity spectrum method can be applied conveniently, and through this method, deformation demand of structure can be considered. However, there is no research for the seismic application in the structure of sheet pile retaining wall to report. Therefore, focusing on laterally loaded stabilizing sheet pile wall, which belongs to flexible cantilever retaining structure and meets the applying requirement of capacity spectrum method from seismic design of building structure, this paper studied an approach of seismic design of sheet pile wall based on capacity spectrum method. In the procedure, the interaction between soil and structure was simplified, and through Pushover analysis, seismic fortification standard was well associated with performance of retaining structure. In addition, by comparing the result of nonlinear time history analysis, it suggests that this approach is applicable.

정재하시험 결과를 통한 타입말뚝 지지력 공식의 타당성 분석 (A Study on the Applicability of Bearing Capacity Formulas of Driven Pile by Comparison with the Results of Static Loading Tests)

  • 천병식;이승범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.544-551
    • /
    • 2004
  • Piles are structural elements made of steel, concrete or timber, and utilize as pile foundation which is one of deep foundations. Driven pile among them, which drives pile into the ground, is fast-constructable, less expensive and it supplies much bearing capacity. For these reasons, its demand is steady. In this study, by selecting the cases which reached ultimate failure during in-situ static loading tests, bearing capacities acquired from these tests were compared with those computed by existing theories and formula. As the results of the analysis, ultimate bearing capacity computed by theoretic formula were less or similar to those of test results in most cases, but lower ground water level and more dense layer where end of piles were reached remarkably high bearing capacity in theoretical methods. ${\beta}-method$ and Korean structure foundation design standard were sensitive to ground physical properties. Meyerhof metbod and API code were relatively independent from site condition.

  • PDF