Effects of $MnO_2$ and $Fe_2O_3$ Additives on the Piezoelectric Properties of 0.05PMN-0.451PT-0.499PZ Ceramics

  • Song, Eun-Seok;Sahn Nahm;Paik, Jong-Hoo;Yoon, Seok-Jin;Park, Jae-Hwan;Ryou, Sun-Youn
    • The Korean Journal of Ceramics
    • /
    • 제6권4호
    • /
    • pp.348-353
    • /
    • 2000
  • The effects of MnO$_2$ and Fe$_2$O$_3$ on the piezoelectric properties of 0.05PMN-0.451PT-0.499PZ ceramics were investigated. The addition of MnO$_2$ increased mechanical quality factor (Q$_m$) but decreased the dielectric constant (K$^{T}_{33}$) and compliance (S$^{E}_{11}$) of the specimens. These results indicated that MnO$_2$ behaves as an acceptor in 0.05MN-0.451PT-0.499PZ ceramics. The electromecanical coupling coefficient (K$_P$) of 0.05PMN-0.451PT-0.499PZ ceramics slightly increased with the addition of MnO$_2$ however, the enhancement of $K_P$ was insignificant. A small amount of Fe$_2$O$_3$ was added to enhance the $K_P$ of the 0.05PMN-0.451PT-0.499PZ + 0.5 wt% MnO$_2$ ceramics. The addition of Fe$_2$O$_3$ largely increased $K_P$ through the increase of the K$^{T}_{33}$ and the polarization. The mechanical quality factor of the specimens decreased with the addition of Fe$_2$O$_3$however, the reduction was negligible.

  • PDF

비납계 Bi0.5Na0.5의 강유전 및 압전 특성에 미치는 Nb-doping 효과 (Nb-doping Effects on Ferroelectric and Piezoelectric Properties of Pb-free Bi0.5Na0.5)

  • 여홍구;성연수;송태권;조종호;정순종;송재성;김명호
    • 한국재료학회지
    • /
    • 제16권11호
    • /
    • pp.705-709
    • /
    • 2006
  • Nb was doped to Pb-free $(Bi_{0.5}Na_{0.5})TiO_3$ (BNT) by a solid state mixing process to form $(Bi_{0.5}Na_{0.5})Ti_{1-x}Nb_xO_3\;(x=0{\sim}0.05)$ (BNTNb) and its doping effects on ferroelectric and piezoelctric properties of BNT were investigated. The BNTNb solid solutions were formed up to x=0.01 with no apparent second phases while grain sizes decreased. As x increased, coercive field ($E_c$) and mechanical quality factor ($Q_m$) decreased but piezoelectric constant ($d_{33}$) increased, which indicates Nb acts as a donor for BNT.

Evaluation of Pain Reduction and Clinical Efficacy of Feedback-Controlled Ultrasonic Scaler

  • Min-ju Kim;Hee-jung Lim;Myoung-hee Kim;Young-sun Hwang;Im-hee Jung
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.176-184
    • /
    • 2023
  • Background: Recently, a piezoelectric ultrasonic scaler based on a feedback control mechanism was introduced for pain relief. This study aimed to investigate the effects of a new ultrasonic scaler in reducing pain and discomfort in adults. Methods: A newly introduced ultrasonic scaler (Master 700®) was used as the test device and a conventional ultrasonic scaler device (PIEZON®) was used as the control device. Forty-one healthy adults visited the dental clinic for dental scaling but did not undergo scaling or periodontal treatment within 6 months. Intraoral examinations were performed before scaling and 3 months later; before scaling, both devices were randomly assigned on the left or right side of each dentition (split-mouth model) and scaling was performed by a registered dental hygienist. The levels of pain and discomfort during scaling were evaluated subjectively and objectively using the visual analog scale (VAS) and physiological monitoring of the heart rate (HR), respectively. Time was measured for each device. Results: All clinical indicators, except bleeding on probing, significantly improved with both devices. The treatment times were 7 minutes, 13 minutes (control) and 6 minutes, 59 minutes (test). VAS scores for pain were 4.89±2.12 (control) and 4.58±2.77 (test) points out of 10; for noise, these were 4.68±2.33 (control) and 4.55±2.55 (test), and for vibration, the values were 4.26±2.0 (control) and 4.18±2.48 (test). HR averages were 72.34±3.39 (control) and 75.97±9.78 (test) beats/min. No statistically significant differences were observed between the devices. Conclusion:The pain, discomfort levels, and scaling time of the new piezoelectric ultrasonic scaler did not differ from those of the conventional device. Further research and development are necessary for more prominent pain-relief effects of scaling devices.

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제42권3호
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

Effects of Pre-synthesized $BaTiO_3$ Addition on the Microstructure and Dielectric/ Piezoelectric Properties of $(Bi_{0.5}Na_{0.5})_{0.94}Ba_{0.06}TiO_3$ Piezoelectric Ceramics

  • Khansur, Neamul Hayet;Yoon, Man-Soon;Kweon, Soon-Yong;Lee, Young-Geun;Ur, Soon-Chul
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.189-189
    • /
    • 2008
  • Due to the environmental issue vast research is going on to replace the widely used lead contented piezoelectric materials. Bismuth sodium titanate (abbreviated as BNT) based bismuth sodium titanate-barium titanate (abbreviated as BNBT) ceramic was prepared by using modified method rather than conventional mixed oxide method. This modification was made to improve the properties of BNT based ceramic. In this procedure $BaTiO_3$ (abbreviated as BT) was prepared using conventional mixed oxide method. Analytical grade raw materials of $BaCO_3$ and $TiO_2$ were weighted and ball milled using ethanol medium. The mixed slurry was dried and sieved under 80 mesh. Then the powder was calcined at $1100^{\circ}C$ for 2 hours. This calcined BT powder was used in the preparation of BNBT. Stoichiometric amount of $Bi_2O_3$, $Na_2CO_3$, $TiO_2$ and BT were weighted and mixed by using ball mill. The used calcination temperature was $850^{\circ}C$ for 2 hours. Calcined powder was taken for another milling step. BNBT disks were pressed to 15 mm of diameter and then cold isostatical press (CIP) was used. Pressed samples were sintered at $1150^{\circ}C$ for 2 hours. The SEM microstructure analysis revealed that the grain shape of the sintered ceramic was polyhedral and grain boundary was well matched where as the sample prepared by conventional method showed irregular arrangement and grain boundary not well matched. And sintered density was better (5.78 g/cc) for the modified method. It was strongly observed that the properties of BNBT ceramic near MPB composition was found to be improved by the modified method compare to the conventional mixed oxide method. The piezoelectric constant dB of 177.33 pC/N, electromechanical coupling factor $k_p$ of 33.4%, dielectric constant $K_{33}^T$ of 688.237 and mechanical quality factor $Q_m$ of 109.37 was found.

  • PDF

초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로) (Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements))

  • 이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.117-124
    • /
    • 2014
  • 본 연구는 초음파 진단 장치에서 초음파 프로브 소자의 결함이 도플러 영상에 미치는 영향을 평가한 것이다. 초음파 프로브 소자결함의 여러 유형 중에서 동일한 방식으로 단선된 초음파 프로브 소자 수를 변화하면서, 도플러 모드 영상에 미치는 영향을 실험으로 살펴보았다. 실험 결과는 첫째, 소자 결함에 따른 도플러 속도는 도플러 소자군 부분에서 급격히 변화하고 있으며, 혈류 속도에는 크게 영향을 받지 않는 것으로 나타났다. 둘째, 도플러 소자군 주변에서 결함 있을 때 소자의 번호가 높은 쪽 소자의 결함에 의한 효과가 작은 것을 알 수 있었다. 셋째, 팬텀의 혈류 속도가 높을수록 도플러 속도 스펙트럼의 폭은 커지지만 크기는 감소하고 있다. 그리고 결함이 증가할수록 도플러 속도와 영상의 밝기의 분산이 더 커지는 것으로 나타났다. 이는 프로브 소자의 결함이 증가하면 전체적으로 시간 평균 도플러 속도 프로파일(TADVP)의 크기가 감소하며 고주파수 영역에서 더 빨리 떨어지는 것으로 알 수 있다.

Mathematical modeling of actively controlled piezo smart structures: a review

  • Gupta, Vivek;Sharma, Manu;Thakur, Nagesh
    • Smart Structures and Systems
    • /
    • 제8권3호
    • /
    • pp.275-302
    • /
    • 2011
  • This is a review paper on mathematical modeling of actively controlled piezo smart structures. Paper has four sections to discuss the techniques to: (i) write the equations of motion (ii) implement sensor-actuator design (iii) model real life environmental effects and, (iv) control structural vibrations. In section (i), methods of writing equations of motion using equilibrium relations, Hamilton's principle, finite element technique and modal testing are discussed. In section (ii), self-sensing actuators, extension-bending actuators, shear actuators and modal sensors/actuators are discussed. In section (iii), modeling of thermal, hygro and other non-linear effects is discussed. Finally in section (iv), various vibration control techniques and useful software are mentioned. This review has two objectives: (i) practicing engineers can pick the most suitable philosophy for their end application and, (ii) researchers can come to know how the field has evolved, how it can be extended to real life structures and what the potential gaps in the literature are.

Optical Properties of a ZnO-MgZnO Quantum-Well

  • Ahn, Do-Yeol;Park, Seoung-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권3호
    • /
    • pp.125-130
    • /
    • 2006
  • The optical gain and the luminescence of a ZnO quantum well with MgZnO barriers is studied theoretically. We calculated the non-Markovian optical gain and the luminescence for the strained-layer wurtzite quantum well taking into account of the excitonic effects. It is predicted that both optical gain and luminescence are enhanced for the ZnO quantum well when compared with those of InGaN-AlGaN quantum well structure due to the significant reduction of the piezoelectric effects in the ZnO-MgZnO systems.

지진전조현상 파악을 위한 전기장 효과에 의한 동물 이상 행동 실험 (Experiment on the Anomalous Animal Behaviors by Electric Field Effects for detecting Earthquake Precursors)

  • 경재복;윤장근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.57-64
    • /
    • 2001
  • There are some previous reports that some animals such as rats and birds move in a large group and act abnormally to avoid the large earthquake. This study is to experimentally testify what relations exist between the anomalous animal behavior and electric field effect, which is reported due to the piezoelectric effects in a basement rock before earthquake occurrences. When electric field is applied to the whole bottom of the cage, they show nervous behaviors such as grooming, washing their faces, standing on legs or running around in panic to avoid the electric field. When more strong electric field is applied, they jump with shrieking and mount on the electric line. The rat shows more sensitive anomalous behavior than the bird. Even though the current to the experimental birds and rats is just a few $\mu$A, they react in various ways. The anomalous animal behaviors under the small ground electric field may have some relations to the actual phenomena before great earthquake. This kind of study is quite worthy for the understanding of earthquake precursors.

  • PDF

벽면의 임피던스변화에 따른 폐공간 내부에서의 음장특성 분석 (Sound Absorption Effects in a Rectangular Cavity According to the Surface Impedance of Wall)

  • 오재응;김상헌;도중석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.687-694
    • /
    • 1997
  • The anisotropy and shape of distributed piezopolymer actuator have advantages over isotropic piezo ceramic materials, since these features of PVDF can be utilized as another design variable in control application. This study is interested in the reduction of sound transmission through elastic plate into interior space by using the PVDF actuator. The plate-cavity system is adopted as a test problem. The vibration of composite plate and the sound fields through plate are analyzed by using the coupled finite element and boundary element method. Some numerical simulations are performed on sound transmission through elastic plates. To investigate the effects of anisotropy and shape of distributed piezopolymer actuator, various kinds of distributed PVDF actuators are applied in sound control simulation for isotropic and anisotropic plates. The PVDF actuators applied are different from each other in their shapes and laminate angles. The results of control simulation show that the control effectiveness of distributed PYDF actuator can be enhanced by using the coupling between shape of actuator and vibration modes of structure and the anisotropy of piezoelectric properties of PVDF.

  • PDF