• 제목/요약/키워드: pier-deck connection

검색결과 6건 처리시간 0.017초

Seismic performance of single pier skewed bridges with different pier-deck connections

  • Attarchiana, Nahid;Kalantari, Afshin;Moghadam, Abdolreza S.
    • Earthquakes and Structures
    • /
    • 제10권6호
    • /
    • pp.1467-1486
    • /
    • 2016
  • This research focuses on seismic performance of a class of single pier skewed bridges with three different pier-deck connections; skew angles vary from $0^{\circ}$ to $60^{\circ}$. A well-documented four span continuous deck bridge has been modeled and verified. Seat-type connections with fixed and sliding bearings plus monolithic pier-deck connections are studied. Shear keys are considered either fully operational or ineffective. Seismic performances of the bridges and the structural components are investigated conducting bidirectional nonlinear time history analysis in OpenSees. Several global and intermediate engineering demand parameters (EDP) have been studied. On the basis of results, the values of demand parameters of skewed bridges, such as displacement and rotation of the deck plus plastic deformation and torsional demand of the piers, increase as the skew angle increases. In order to eliminate the deck collapse probability, the threshold skew angle is considered as $30^{\circ}$ in seat-type bridges. For bridges with skew angles greater than $30^{\circ}$, monolithic pier-deck connections should be applied. The functionality of shear keys is critical in preventing large displacements in the bearings. Pinned piers experience considerable ductility demand at the bottom.

Effect of a two bearing lines deck on the bridge substructure

  • Shaker, Fatemeh;Rahai, Alireza
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.117-129
    • /
    • 2022
  • This research evaluated the different types of deck to pier connections effects (one or two elastomeric bearing lines and rigid) on a concrete bridges. Three-dimensional bridge models behavior with different deck to pier connections and different distances of two bearing lines were studied under the service load. Also, the detailed connection system with two elastomeric bearing lines was modeled to evaluate the effect of changing distance between two-lines. Results indicated that the proper location of elastomeric bearings has a major impact on the transferring forces to the substructure. Double elastomeric bearing lines have a behavior between one line and rigid connections. Transferring bending moment to the substructure in two-lines is more than the corresponding value of the one line. Moreover, an increase in the distance of two-lines lead to a significant increase in the rotational stiffness of the connection, and an analytical solution was investigated for their relation. In fact, the semi-rigidity effect of this connection and its change due to the distance of bearings should be considered in the design process.

Response modification factors of concrete bridges with different bearing conditions

  • Zahrai, Seyed Mehdi;Khorraminejad, Amir;Sedaghati, Parshan
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.185-196
    • /
    • 2019
  • One of the shortcomings of seismic bridge design codes is the lack of clarity in defining the role of different seismic isolation systems with linear or nonlinear behavior in terms of R-factor. For example, based on AASHTO guide specifications for seismic isolation design, R-factor for all substructure elements of isolated bridges should be half of those expressed in the AASHTO standard specifications for highway bridges (i.e., R=3 for single columns and R=5 for multiple column bent) but not less than 1.50. However, no distinction is made between two commonly used types of seismic isolation devices, i.e., elastomeric rubber bearing (ERB) with linear behavior, and lead rubber bearing (LRB) with nonlinear behavior. In this paper, five existing bridges located in Iran with two types of deck-pier connection including ERB and LRB isolators, and two bridge models with monolithic deck-pier connection are developed and their R-factor values are assessed based on the Uang's method. The average R-factors for the bridges with ERB isolators are calculated as 3.89 and 4.91 in the longitudinal and transverse directions, respectively, which are not in consonance with the AASHTO guide specifications for seismic isolation design (i.e., R=3/2=1.5 for the longitudinal direction and R=5/2=2.5 for the transverse direction). This is a clear indicator that the code-prescribed R-factors are conservative for typical bridges with ERB isolators. Also for the bridges with LRB isolators, the average computed R-factors equal 1.652 and 2.232 in the longitudinal and transverse directions, respectively, which are in a good agreement with the code-specified R-factor values. Moreover, in the bridges with monolithic deck-pier connection, the average R-factor in the longitudinal direction is obtained as 2.92 which is close to the specified R-factor in the bridge design codes (i.e., 3), and in the transverse direction is obtained as 2.41 which is about half of the corresponding R-factor value in the specifications (i.e., 5).

Seismic fragility of a typical bridge using extrapolated experimental damage limit states

  • Liu, Yang;Paolacci, Fabrizio;Lu, Da-Gang
    • Earthquakes and Structures
    • /
    • 제13권6호
    • /
    • pp.599-611
    • /
    • 2017
  • This paper improves seismic fragility of a typical steel-concrete composite bridge with the deck-to-pier connection joint configuration at the concrete crossbeam (CCB). Based on the quasi-static test on a typical steel-concrete composite bridge model under the SEQBRI project, the damage states for both of the critical components, the CCB and the pier, are identified. The finite element model is developed, and calibrated using the experimental data to model the damage states of the CCB and the bridge pier as observed from the experiment of the test specimen. Then the component fragility curves for both of the CCB and the pier are derived and combined to develop the system fragility curves of the bridge. The uncertainty associated with the mean system fragility has been discussed and quantified. The study reveals that the CCB is more vulnerable than the pier for certain damage states and the typical steel-concrete composite bridge with CCB exhibits desirable seismic performance.

교량의 비탄성 지진응답에 대한 아칭작용의 영향 (Arching Action Effect for Inelastic Seismic Responses of Bridge Structures)

  • 송종걸;남왕현
    • 대한토목학회논문집
    • /
    • 제29권2A호
    • /
    • pp.131-143
    • /
    • 2009
  • 지진하중과 같은 횡하중에 대하여 교량구조물의 아칭작용은 교대 사이의 상부구조에 의해 발생하며 이를 상부구조의 저항능력이라고도 한다. 교량구조물의 아칭작용의 크기는 경간의 수에 영향을 받으며 또한 상부구조, 교대와 교각의 연결조건 및 상부구조와 하부구조의 강성비에도 영향을 받는다. 프리캐스트 콘크리트 상자형 교량의 비탄성 지진응답에 대한 아칭작용의 영향을 분석하기 위하여 경간수에 따른 두 가지 종류의 예제교량(교량 SB와 교량 LB), 교각의 높이의 배열에 따른 세가지 종류(대칭, 비대칭)의 교량, 상부구조와 하부구조의 연결조건에 따른 세가지 교량(형식 A, B, C)등에 대한 구분을 조합하여 18가지 종류의 예제구조물을 작성하였으며, 이 예제구조물들에 대하여 역량스펙트럼해석, 비탄성 시간이력해석을 수행하여 지진응답을 비교하여 아칭작용의 영향을 분석하였다. 아칭작용의 영향(최대변위의 감소와 저항능력의 증가)은 교량 SB(short bridge)의 경우가 교량 LB(long bridge) 보다 크게 나타났으며 대칭교량의 경우가 비대칭교량에 비하여 크게 나타남을 알수 있었다.

조립식교량의 콘크리트 방호울타리 연결시스템 개발을 위한 실험적 연구 (An Experimental Study on Development Connection System of Concrete Barrier in Modular Bridges)

  • 정호성;이상승;최진웅;김태완;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.49-57
    • /
    • 2012
  • 최근 교량의 건설에서는 공사기간의 단축 등을 위해 조립식 형태의 교량 시공이 연구되고 있다. 하지만 이는 대부분이 주 구조물인 교각, 거더와 바닥판 등에 국한되어 있고, 조립식 교량에 적합한 방호울타리와 같은 부대시설에 대한 연구는 미흡한 실정이다. 이에 본 연구에서는 조립식 교량 적용을 위한 콘크리트 방호울타리 연결 시스템을 제안하고, 제안된 시스템의 구조적 성능을 검증하기 위하여 정적 실험을 수행 하였다. 변수는 볼트의 수직 수평 접합방식으로 기준실험체와의 비교를 통해 조립식 교량에 적합한 콘크리트 방호 울타리 연결시스템을 제안하고자 하였다. 그 결과, 볼트의 수직접합이 구조적 성능 및 건전성이 일체형의 기준실험체와 거의 동일하다는 것을 알 수 있었고, 조립식교량 적용을 위한 연결시스템으로 적당하다고 판단된다.