• Title/Summary/Keyword: pier scour

Search Result 97, Processing Time 0.019 seconds

A Study on The Bed Scour at Stream Bridge during Flood - In the case of Jeongjang Bridge in Gurye - (홍수시 소하천 교량에서의 하상세굴 연구 - 구례 정장교를 중심으로 -)

  • Jung, Jae-Sung;Chung, Mahn;Kim, Min-Hwan
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1075-1080
    • /
    • 2002
  • The hydrological frequency of the flood in July 2000 at Seosi stream basin in Gurye and the bed scour of the stream channel were estimated to investigate the bed scour related with Jeongjang bridge collapse. The storm over the basin in July 2000, 303mm/day was 103year frequency rainfall and the equivalent flood was 2580cms. As the results of 100year and 30year flood application, flood level 30.78~31.38m and mean velocity 3.79~4.03m/s were appeared. And the purification project of Seosi stream increased the velocity of the section near to Jeongjang bridge by the improvement of conveyance at the downstream. The local scour at pier was the major factor of bed scour at Jeongjang bridge site and the total scour at pier No.6 was increased from 2.32m to 2.45m by the purification project.

A Study on the Scour Depth Equation in Bight River (하천 만곡부에서의 세굴심 산정식에 관한 연구)

  • Choi, Han-Kuy;Park, Je-Wan;Park, Soo-Jin
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.47-55
    • /
    • 2012
  • Currently, we only estimate the average flood water level by the cross-sections of the river using one-dimensional numerical analysis when establishing the basic plans. However, the reliability decreases when it comes to the river bend. In river bend, the difference of water-level between the inside and the outside of the river arises by centrifugal force. And it is estimated less than what it could be estimated when establishing the plan with average estimate of flood level. It is apprehended that the exterior of the river will be under-constructed when establishing the scour depth only with the mean depth. In the case of local scour of the abutment, it is difficult to estimate its depth precisely, and it tends to be over-estimated in the case of the empirical formulas. Therefore, the modification considering the deviation of the water depth of the exterior of the river bend is needed. In observing the deviation of each formula in river bend, it is found: Andru's formula for 58%, followed by the Laursen's for 26%, and the C.S.U's for 17% in pier, while it is 44% for Froehlich's formula in abutment. Under the 500CMS of the flood discharge, the deviation of the scour depth between pier and abutment was about 10 %. However, in further flood discharge, it shows 24~58% the biggest in deviation of piers. It is concluded that the scour depth estimate should be done with 2-dimensional numerical analysis.

  • PDF

Field Investigation of Bridge Scours in Small and Medium Streams(2) (우리나라 중.소 하천의 세굴특성 조사연구(2))

  • Yeo, Un-Gwang;Gang, Jun-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.1
    • /
    • pp.49-59
    • /
    • 1999
  • In order to understand the present situation of bridge scouring and to provide the fundamental information for bridge design, in-situ measured data is analyzed for bridge scours at small and medium streams in the heartland of Korea. The physical parameters affecting the bridge scouring such as flow depth, velocity, pier length and width, scouring depth, and the angle between flow and pier are extensively surveyed and measured. According to the locality and the pier type data are classified to analyze. With these data, some important factors for the scour depth such as flow depth, angle and Froude number are investigated and applied to existing formulas proposed by many researchers. In addition, the computational results are compared with the measured and some of the applicable formulas in this region are recommended.

  • PDF

An Experimental Study on Local Scour Around Group Pile Foundation (군말뚝 주변의 국부세굴에 관한 연구)

  • Yun, Byeong-Man;Seo, Jeong-Pil;No, Yeong-Sin
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.641-649
    • /
    • 2001
  • This study analyzed the general scour characteristics around group pile foundations through laboratory experiments. The experiments were performed for the pile groups consisting of 4, 9, 15 and 35 piles to investigate the effects of pile number, mean velocity and the angle of attack on the scour hole shape, and the magnitude and the position of maximum scour depth. Results reveal that the maximum scour depth for 4 and 9 piles have almost same values with single pier case regardless of approach velocity. The scour depth for 15 and 35 piles, however, increases as the mean velocity increases and reaches up to 2.2 times of maximum scour depth for single pier case. As the number of piles increase, the single scour holes are superposed and the overall scour hole turned out to be rectangular shape. The experimental results for the case of 35 piles indicate that the scour depth has the maximum value at angle of attack of 35 degree and that the main scour hole is formed in diagonal direction.

  • PDF

Computations of Numerical Deviations of Equations for Souring Depth Comparing with 1-D and 2-D Numerical Model (1, 2차원 수치해석에 따른 기존 세굴심 산정식 편차 산정)

  • Choi, Han-Kuy;Park, Tae-Hyun;Lee, Yeong-Seop
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.185-191
    • /
    • 2008
  • This study tried the 1st, 2nd dimensional numerical analysis according to the pier's shape, size and installing method in order to compare the depth of scour calculation method using the variables calculated by using the 2nd dimensional numerical analysis with the calculated depth of scour value by using the calculated variables by using the 1st dimensional numerical analysis. And then verified the problems occurring when the depth of scour is calculated by using the calculated values by using the 1st dimensional numerical analysis, as calculating the deviation depending on it.

  • PDF

Review on Applicability of Local Scour Depth Calculation Formula in River (하천 세굴심 산정을 위한 교각 세굴심 산정식의 적용성 검토)

  • Min, ByungYun;Chang, HyungJoon;Lee, HoJin;Kim, SungDuk
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • The basic analysis of Soil and structural mechanics for the bridge substructure affected by the flow of water is sufficient in the construction of such bridges, but the stability of scour resulting from hydraulic phenomena is insufficient. In addition, it is not enough to estimate the scour depth of the bridge which reflects the watershed characteristics of the domestic river because it uses the formula for calculating the scour depth of the overseas piers in calculating the scour depth of the bridge. In this study, the application of the CSU (1993) formula, which is currently applied to the national river design criteria, was reviewed between the two formulas after calculating the scour after calculating the scour by applying another bridge deck scour calculation formula to take into account the uncertainty in the calculation of scour. In this study, in addition to the CSU (1993) formula, which is currently applied to Korean river design criteria, another scour depth calculation formula is applied to calculate uncertainty in scour depth calculation, was reviewed between the two formulas. The review confirmed that the SSE (%) showed a difference of at least 2.08%, up to 91.23%, and SSEn(%) at least 0.19%, up to 415.91%, when compared to the measured depth of the pier based on the hydraulic model experiment and the depth of the pier calculated with the nine scour depth formulas in use. In other words, it is confirmed that there are many differences between the scouring formulas of piers. The results of this study are expected to be used to estimate scour depth in future river design.

5-SRICOS Method : Prediction of Scour Depth Around Bridge Piers in Cohesive Soils (S-SRICOS 방법 : 점성토지반의 교각세굴깊이 예측)

  • 곽기석
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.13-21
    • /
    • 2002
  • A new method called S-SRICOS is proposed to predict the local scour depth around bridge piers. The S-SRICOS method is a simplified version of the SRICOS method which was developed to predict the scour depth versus time curve around bridge piers. The SRICOS method which considers the time effect based on the soil properties and the hydraulic parameters can handle a multi-flood hydrograph and multi-layer soil systems with the SRICOS program. An attempt was made to simplify the method to the point where only hand calculations would be required. The concept of the equivalent time was developed leer this purpose. The S-SROICOS method requires only 4 parameters such as pier width, design bridge life, design velocity corresponding to the design bridge life, and initial scour rate of the soil. The S-SRICOS method was verified against 55 cases of the scour depth results using the SRICOS method.

Experimental Study on Local Scour around Bridge Piers by Scour Protection Devices (세굴보호장치에 의한 교각주위의 국부세굴 실험)

  • 최기봉;김응용
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.126-131
    • /
    • 2000
  • This study based on the laboratory works, analyzes factors affecting local scour in order to understand various characteristics of the local scour surrounding bridge piers. Attached with scour protection device as a method for decreasing local scour, it carries out the laboratory experiments and calculates the scour depth. From the experiments attached with the scour protection devices, it seems possible to reduce the scour depth as the protecting plate, column and sacrificial piles are built in the same height with flume bed at pier or footing upstream interrupted falling-flow. And then it could reduce scour depth. The paper presents the following research results: First, the decreasing degree of scour depth is in order of protecting column, protecting plate, sacrificial piles and non-protecting facilities. However, it shows no meaningful difference between protecting column and protecting plate. Second, when $L_p/b$=0.5~1, the decreasing effect of scour depth reached the maximum of 40 percents.

  • PDF

Pier-Scour Characteristics of the Marine Bridge with Ship Impact Protection - Incheon Bridge Case - (선박충돌방지공이 설치된 해상교량의 교각 세굴 특성 분석 - 인천대교를 대상으로 -)

  • Yeo, Woon-Kwang;Ji, Un;Kim, Chang-Sung;Lim, Jong-Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • More recently, the massive marine bridges in a ship passage have been constructed on the sea. Therefore, the ship impact protection for the bridge-piers are installed to consider the possibility of vessel collision danger. Due to the ship impact protection, the pier-scour characteristics are changed in comparison with the condition without the ship impact protection (SIP). In this study, the physical modeling for the Incheon Sea-Crossing Bridge was performed to analyze the pier-scour characteristics with respect to the vessel collision protection. The rigid and movable bed tests were conducted to evaluate the flow pattern, scour depth, and scourhole with and without the ship impact protection. The experimental results for the maximum scour depth is increased 0.24 m in W1 pier at the same location and 2.4 m in W2+3+4 piers due to the SIP installation. Especially, the maximum scour depth in W2+3+4 piers was occurred around the SIP.

Scour Impact on the Horizontal Bearing Capacity of Pier-Type Dolphin Structures (잔교식 돌핀 구조물의 수평 지지력에 세굴이 미치는 영향 검토)

  • Tae Young Jeong;Su Won Kang;Kyu Won Kim;Jong Hwa Won;Chan Joo Kim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.138-145
    • /
    • 2023
  • A study using numerical analysis techniques was conducted to examine the scour effect of pier-type dolphin structures installed in the domestic marine environment, and the effect of scour on horizontal bearing capacity was examined. In this study, we designed the berthing structures, taking into account the environmental and ground conditions of the target maritime area, and after calculating the predicted scour area, stability evaluation was performed by removing the ground elements of the area. The increase in scour depth was found to induce a direct decrease in horizontal bearing capacity due to soil loss in contact with the foundation, establishing a relationship that increases horizontal displacement. However, in the foundation designed to withstand the design load by reflecting the safety rate, the increase in horizontal displacement formed by possible scour is not large, which did not have a dominant effect on the horizontal bearing capacity of the foundation. In the future, research is required to analyze the impact of each factor and formalize evaluation and design techniques to evaluate the scour safety of marine foundations and pier-type structures installed in various ground conditions and structural formats.