• 제목/요약/키워드: physical measurement

검색결과 2,917건 처리시간 0.035초

Evaluations of a Commercial CLEANBOLUS-WHITE for Clinical Application

  • Geum Bong Yu;Jung-in Kim;Jaeman Son
    • 한국의학물리학회지:의학물리
    • /
    • 제35권1호
    • /
    • pp.10-15
    • /
    • 2024
  • Purpose: This study aimed to comprehensively investigate the diverse characteristics of a novel commercial bolus, CLEANBOLUS-WHITE (CBW), to ascertain its suitability for clinical application. Methods: The evaluation of CBW encompassed both physical and biological assessments. Physical parameters such as mass density and shore hardness were measured alongside analyses of element composition. Biological evaluations included assessments for skin irritation and cytotoxicity. Dosimetric properties were examined by calculating surface dose and beam quality using a treatment planning system (TPS). Additionally, doses were measured at maximum and reference depths, and the results were compared with those obtained using a solid water phantom. The effect of air gap on dose measurement was also investigated by comparing measured doses on the RANDO phantom, under the bolus, with doses calculated from the TPS. Results: Biological evaluation confirmed that CBW is non-cytotoxic, nonirritant, and non-sensitizing. The bolus exhibited a mass density of 1.02 g/cm3 and 14 shore 00. Dosimetric evaluations revealed that using the 0.5 cm CBW resulted in less than a 1% difference compared to using the solid water phantom. Furthermore, beam quality calculations in the TPS indicated increased surface dose with the bolus. The air gap effect on dose measurement was deemed negligible, with a difference of approximately 1% between calculated and measured doses, aligning with measurement uncertainty. Conclusions: CBW demonstrates outstanding properties for clinical utilization. The dosimetric evaluation underscores a strong agreement between calculated and measured doses, validating its reliability in both planning and clinical settings.

암환자의 삶의 질 도구개발 (Development of Quality of Life Measurement for Cancer Patients)

  • 태영숙;강은실;이명화;박금자
    • 성인간호학회지
    • /
    • 제12권4호
    • /
    • pp.741-757
    • /
    • 2000
  • This study was undertaken to develop an instrument to be used for measuring the concept of quality of life of Korean patients with cancer multidimensionary and correctly. It can contribute in holistic nursing care for Korean cancer patients and also provide and validate basic data to help oncology nurses measure the outcome of nursing intervention correctly. To develop this instrument, the researchers first estabilished a conceptual framework based on the results of qualitative data analysis and indepth interview method Development of the scale was conducted using a method in which 31 items were assessed by subjects' self report using linear analogue scales. The subjects were 79 D.M. patients, 103 patients with acute illness, and 91 cancer patients residing in Busan, Korea. Data were collected during the period from July, 24 to August 14, 2000. This instrument consisted of 31 items with a self report scale. This instrument covered 4 dimensions of cancer patients : 1) physical wellbeing 2) psychological wellbeing 3) social wellbeing and 4)spiritual wellbeing. Each item had a possible score of 10. The reliability of the scale was tested with Cronbach's alpha. Validity was evaluated by examining the relationships of this scale, Youn's Quality of Life Questionnare scores and the Simple Quality of Life scale. Two separate runs of multiple regression were used to predict scores on the Simple Quality of Life measurement. Further validation was obtained by examining the correlation between the instrument subscores and Youn's Quality of Life measurement subscore for convergence of this scale. Examination of the discriminant. power of the instrument was done using ANOVA test. The results are summarized as follows: 1. The reliability of the instrument for the quality of life was 0.8321(Cronbach's alpha.), physical wellbeing dimension 0.6343, psychological wellbeing dimension 0.6501, spiritual wellbeing dimension 0.5883. 2. This instrument had a high correlation with Youn's Quality of Life measurement(r= 0.636) in cancer patients, whereas it had a low correlation with Simple Quality of Life measurement(r=0.455) in cancer patients. In the D.M. patients, the instrument correlated with both the Youn's Quality of Life measurement and Simple Quality of life measurement(r=0.313, r= 0.407) and in the acute stage patients, the instrument had no correlation. 3. Multiple regression of individual items on the Simple Quality of Life scores accounted for 56.8% of the variance in the Simple Quality of Life measurement, whereas, Youn's Quality of Life measurement scores accounts for 31.7%. 4. The correlations collected from the three group had the same patterns of variations but especially the instrument developed in this study had higher disciminant power than that of Youn's Quality of Life Measurement.

  • PDF

Variation in Significant Difference of Sausage Textural Parameters Measured by Texture Profile Analysis (TPA) under Changing Measurement Conditions

  • Shin, Sun-Hwa;Choi, Won-Seok
    • 한국축산식품학회지
    • /
    • 제41권4호
    • /
    • pp.739-747
    • /
    • 2021
  • This study examined the measurement conditions of the texture profile analysis (TPA) experiments that are typically used to measure the physical properties of sausage. As the measurement conditions (compression ratio and cross-head speed) were changed, the significant differences between the values of textural parameters (hardness, adhesiveness, springiness, cohesiveness, chewiness) of samples changed. Furthermore, among the measurement conditions, there was more variation in the significant difference between the value of samples due to a change in the compression ratio than due to a change in the cross-head speed. The highest variation in significant difference was observed between the values of cohesiveness of samples due to changes in measurement conditions, whereas the lowest variation in significant difference was observed between the values of springiness of samples due to change in measurement conditions. Therefore, it is desirable to provide a clear basis for setting specific measurement conditions for TPA test, since significant differences in the values of textural parameters of samples were caused by differences in cross-head speed or compression ratio, not by a difference in samples, when analyzing the cohesiveness of sausage, especially.

Digora$\textregistered$에서 정량영상의 특성에 대한 평가 (The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$)

  • 김재덕
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

van der Pauw method를 이용한 금속도전율 표준시편 개발 (Development of Conductivity Standards for Metals using the van der Pauw Method)

  • 강전홍;유광민;이상화
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1617-1620
    • /
    • 2013
  • The widely-used measurement methods for conductivity of non-magnetic metals are van der Pauw method, Two Point Probe method and Eddy Current method. Among them a more simpler and easier method is the Eddy Current method and an instrument using the method is a Conductivity Meter which can measure a conductivity by contacting its probe on a sample surface. However, conductivity standards are essentially needed to confirm the meter's performance or to calibrate it. In this study, six kinds of the standards which are made of Cu, Al-1, Al-2, brass, Zn and SUS-316 are developed and conductivity ranges for the standards are 2.27 %IACS ~ 101.6 %IACS with measurement uncertainty of less than 0.3 %.

측만증 환자에서 3차원 체표면 영상분석과 Cobb 각의 상관관계 (Correlation of the 3D-Surface Topography and Cobb's Angle in Scoliotic Patient's)

  • 최은정;김태열
    • 대한임상전기생리학회지
    • /
    • 제3권1호
    • /
    • pp.61-70
    • /
    • 2005
  • The purpose of study correlation between 3D-surface topography and Cobb angle in scoliotic patients. It would be recognizing possibility of clinical application with 3D-surface topography with scoliosis assessment and correlation analysis of obtained Cobb angle through measured results of surface topography and took X-ray of subjects with scoliosis, which used to 3D-surface topography of laser scan method. A scoliosis subjects 16(males 4, females 12) agreed for study's purport volunteer our study that diagnose the scoliosis through 3D-surface topography and X-ray. The results were as follow: It was shown that the relation of Cobb angle of scoliosis and itemized 3D-surface topography measurement in horizontal view(p<0.01). top difference of cervicothoracic and lumbar in anterior-posterior view(p<0.05), the top difference of thoracic, thoracolumbar(p<0.01). These results suggest that an itemized 3D-surface topography measurement was highly correlated with Cobb angle. It would be a useful diagnosis method and assessment of physical therapy plan.

  • PDF

Reliability of Thickness Measurements of the Abductor Hallucis Muscle Using the Spring Gauge Technique in Hallux Valgus Subjects: An Ultrasonographic Study

  • Jeon, In-cheol;Kim, Moon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • 제28권2호
    • /
    • pp.119-123
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurements of the abductor hallucis (AbdH) in subjects with hallux valgus (HV), using ultrasonography performed at different inward pressures of approximately 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg, with no pressure control. Methods: Thirty-two subjects with HV were recruited. The thicknesses of both sides of the AbdH were measured randomly by two different examiners for assessment of the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability of MT measurements of the AbdH, while ICC (3,1) was used to assess the intra-rater reliability. Results: The results showed higher ICC values for intra-rater reliability compared to inter-rater reliability, and the value for inter-rater reliability with no pressure control (ICC=0.74 [95%CI=0.53-0.87]) was smaller compared to pressures of 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg. Other inward pressures for intra- and inter-rater reliability also showed excellent values (ICC=0.86-0.96). Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results in measurement of the MT of the AbdH by different examiners in a clinical setting.

보바스 접근방법이 정신지체 아동의 균형 및 운동능력에 미치는 영향: 단일사례연구 (The Effect of the Bobath Approach on Balance and Motor Ability in Mentally Retarded Child)

  • 노효련
    • 대한물리치료과학회지
    • /
    • 제15권2호
    • /
    • pp.79-86
    • /
    • 2008
  • Background: The purpose of this study was to present a practical method of medical treatment to improve the balance and motor ability of the mentally retarded child with a single mentally retarded child-subject. Methods: The subject of the study was a 39-month-old mentally retarded female. This study included a 2-week basic period and a 13-week treatment period. The treatment method was based on the Bobath Approach. Gross motor function measurement (GMFM) was used to examine changes in motor ability, and the Pediatric Balance Scale (PBS) was used to measure changes in balance ability. The curative program was composed of normalization of muscle tone, strengthening of leg endurance and muscular strength, the improvement of trunk alignment, and the increase of balance. Visual rate of change was used to examine the results. Results: As a result of this study, balance ability increased on the Pediatric Balance Scale (PBS) by 24 points, and motor function increased in terms of Gross Motor Function Measurement (GMFM) by 6.9% (18 points). Standing increased by 41% (16 points), and walking, running, and jumping increased by 31.9% (23 points) compared to thebasic period. Therefore, the Bobath Approach appears to be an appropriate method to improve balance and motor ability in mentally retarded children. Conclusion: It is surmised that aggressive intervention by physical therapists and occupational therapists, and a follow-up study, are required for the growth of motor ability in mentally retarded children.

  • PDF

고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성 (Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement)

  • 김용욱
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

전기치료와 키네시오 테이핑 요법이 테니스 엘보 환자의 통증과 악력에 미치는 영향 (The Effects of Electrical Therapy and Kinesio Taping on the Grip Strength and Pain in Tennis Elbow Patients)

  • 이광재
    • 대한물리치료과학회지
    • /
    • 제21권1호
    • /
    • pp.53-58
    • /
    • 2014
  • Background : The purpose of this study is to identify the level of positive influence on the pain and the gripping power in patients with tennis elbow by comparing the TENS treatment method and the kinesio taping therapy with good accessibility among the kinesio taping therapy and electrical therapy. Methods : Targeting the patients diagnosed with tennis elbow, the subjects were categorized in groups of four, each of electrical therapy group and kinesio tape therapy group where the degree of pain reduction through VAS before and after the treatment of each group and the measurement of the degree of gripping power increase using the gripping power measurement tool as well as the pain reduction changes and gripping power increase before and after the treatment between the two groups were compared. Result : As a result, the electrical therapy group and the kinesio tape group were able to obtain the results of pain reduction and gripping power increase through VAS before and after the treatment, but for all pain reduction and gripping power increase, it had no statistically significant changes(p>.05). In addition, in the changes of pain reduction and changes of gripping power increase before and after the treatment, there were no statistically significant differences between the electrical therapy group and the kinesio tape group(p>.05). Conclusion : Based on the results so far, it is thought that the kinesio taping therapy can positively influence the pain reduction of patients with tennis elbow and increase of gripping power.

  • PDF