• 제목/요약/키워드: physical characteristic parameters

검색결과 86건 처리시간 0.027초

Design of intelligent estimation of composite fluid-filled shell for three layered active control structure

  • Ghamkhar, Madiha;Hussain, Muzamal;Khadimallah, Mohamed A.;Ayed, Hamdi;Naz, Muhammad Yasin;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • 제29권2호
    • /
    • pp.117-126
    • /
    • 2022
  • The vibrational characteristic of three-layered cylindrical shell (CS) submerged in fluid with the ring support has been studied. The inner and outer layer is supposed to construct by isotropic layer. The composition of central layer is of functionally graded material type. Acoustic Wave condition has been utilized to present the impact of fluid. The central layer of cylindrical shell (CS) varies by volume fraction law that has been expressed in terms of polynomial. The main shell frequency equation has been obtained by theory of Love's shell and Rayleigh-Ritz technique. The oscillation of natural frequency has been examined under a variety of end conditions. The dependence of axial model has been executed with the help of characteristic beam function. The natural frequencies (NFs) of functionally graded material (FGM) shell have been observed of cylindrical shell along the shell axial direction. Different physical parameters has been used to examine the vibration characteristics due to the effect of volume fraction law. MATLAB software has been used to get result.

Preparation of sputter-deposited CuOx thin film with p-type conductivity and application as thin film transistor

  • So Jeong Park;Eui-Jung Yun
    • Journal of the Korean Physical Society
    • /
    • 제81권
    • /
    • pp.867-875
    • /
    • 2022
  • This paper explored the effect of deposition conditions on the characteristics of copper oxide (CuOx) thin films prepared by direct current (DC) magnetron sputtering. X-ray diffraction exhibited that CuO with n-type conductivity was the main composition regardless of the DC magnetron sputtering power whereas the phase transition from n-type CuO to p-type Cu2O was observed with decreasing the oxygen pressure (OP) from 40 to 20%. The optical band gap ranges of 1.6-1.9 eV, which are characteristic of n-type CuO, were determined for samples prepared with OPs of 30-40% while the optical band gap of 2.3 eV, which is characteristic of p-type Cu2O, was measured for samples prepared with an OP of 20%. In addition, only Cu+ X-ray photoelectron spectroscopy (XPS) peak at the ~932.6 eV position exists in the films deposited with an OP of 20%, whereas only Cu2+ XPS peaks at ~934.2 eV and in the range of 940-945 eV are observed in the films deposited with an OP of 40%. Furthermore, as a result of XPS depth profile analysis, it was confirmed that the composition ratio of the sample prepared at an OP of 20% was Cu2O, whereas the composition ratio of the sample prepared at an OP of 40% was CuO. These suggest that the CuOx thin films could be constantly converted from n-type CuO to p-type Cu2O by decreasing the oxygen partial pressure. Thin film transistors with Cu2O deposited at 20% OP revealed p-type characteristics such as onset voltage (VON) of -3 V, saturated hole mobility of 8 cm2/Vs at VGS = -28 V, subthreshold swing of 0.86 V/decade at VGS-VON = -0.5 V, and on/off ratio of 1.14 × 103.

무구속 심탄도 모니터링 시스템을 이용한 스트레스 분석 기초연구 (Basic Study for Stress Analysis Using an Unconstrained BCG Monitoring System)

  • 노윤홍;정도운
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.118-123
    • /
    • 2011
  • Heart related diseases mainly caused by heavy work load and increasing stress in human daily life. Therefore, researches on mobile healthcare monitoring for daily life has been carried out. Notably, wearable healthcare monitoring system which has least restriction has been tried to provide an emergency alert of abnormal heart rate. In this study, we developed chair type unconstrained BCG measurement system which able to perform continuous heart status monitoring at the office and daily life in the unconstrained way. Furthermore, adaptive threshold is used to detect the heart rate from BCG signals. The HRV(heart rate variability) is calculated from heart rate interval. ECG signal measured using conventional method and BCG signal measured using unconstraint system are carried out simultaneously for the purpose of performance evaluation. From the comparison result, BCG signal shows a similar heart beat characteristic as ECG signal. This proves the possibility of practical implementation of unconstraint healthcare monitoring system. In addition, medical examination like valsalva maneuver is performed to observe the changes in HRV due to stress. By performing valsalva maneuver, heart is said to be placed under an artificial physical stress condition. Under this artificial physical stress condition, the time and frequency domain of HRV parameters are evaluated.

무선 센서용 표면탄성파의 3 차원 모델링 (3D modeling of a surface acoustic wave for wireless sensors)

  • 트렌 녹 쿵;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2009
  • In this work, we discuss simulation of surface acoustic wave device using Comsol Multiphysics. The structure SAW device based on piezoelectric thin film aluminum-nitride (AlN) on silicon was simulated. Some parameters of SAW device such as surface velocity, displacement of piezoelectric thin film were evaluated by software. Many modes and shapes of wave are also discussed in this paper. For evaluation physical parameters of AlN piezoelectric layer, the SAW resonator was modeled and simulation results were also compared with experiment results. we simulated arid evaluated the surface Rayleigh wave of AlN thin film on silicon substrate. Results simulation and experiment showed the surface velocity of AlN thin film was about 5200 m/s and shape of surface wave was also displayed. This paper has also proposed as method to study SAW characteristic of piezoelectric thin film and found out measurement values accurately of film such as stiffness matrix, piezoelectric matrix. These values are very important in calculation and design SAW device or MEMS device based on AlN piezoelectric layer.

  • PDF

Multiple Constraint Routing Protocol for Frequency Diversity Multi-channel Mesh Networks using Interference-based Channel Allocation

  • Torregoza, John Paul;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제10권12호
    • /
    • pp.1632-1644
    • /
    • 2007
  • Wireless Mesh Networks aim to attain large connectivity with minimum performance degradation, as network size is increase. As such, scalability is one of the main characteristics of Wireless Mesh Networks that differentiates it from other wireless networks. This characteristic creates the need for bandwidth efficiency strategies to ensure that network performance does not degrade as the size of the network increase. Several researches have been done to realize mesh networks. However, the researches conducted were mostly focused on a per TCP/IP layer basis. Also, the studies on bandwidth efficiency and bandwidth improvement are usually dealt with as separate issues. This paper aims to simultaneously study bandwidth efficiency and improvement. Aside from optimizing the bandwidth given a fixed capacity, the capacity is also increased using results of physical layer studies. In this paper, the capacity is improved by using the concept of non-overlapping channels for wireless communication. A channel allocation scheme is conceptualized to choose the transmission channel that would optimize the network performance parameters with consideration of chosen Quality of Service (QoS) parameters. Network utility maximization is used to optimize the bandwidth after channel selection. Furthermore, a routing scheme is proposed using the results of the network utilization method and the channel allocation scheme to find the optimal path that would maximize the network gain.

  • PDF

Design and fabrication of an optimized Rogowski coil for plasma current sensing and the operation confidence of Alvand tokamak

  • Eydan, Anna;Shirani, Babak;Sadeghi, Yahya;Asgarian, Mohammad Ali;Noori, Ehsanollah
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2535-2542
    • /
    • 2020
  • To understand the fundamental parameters of Alvand tokamak, A Rogowski coil with an active integrator was designed and constructed. Considering the characteristics of the Alvand tokamak, the structural and electrical parameters affecting the sensor function, were designed. Calibration was performed directly in the presence of plasma. The sensor has a high resistance against interference of external magnetic fields. Plasma current was measured in various experiments. Based on the plasma current profile and loop voltage signal, the time evolution of plasma discharge was investigated and plasma behavior was analyzed. Alvand tokamak discharge was divided into several regions that represents different physical phenomena in the plasma. During the plasma discharge time, plasma had significant changes and its characteristic was not uniform. To understand the plasma behavior in each of the phases, the Rogowski sensor should have sufficient time resolution. The Rogowski sensor with a frequency up to 15 kHz was appropriate for this purpose.

High Pressure Synthesis and Physical Properties of the Solid Solution, $SrLaAl_{1-x}Ni_xO_4(0

  • 변송호
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권11호
    • /
    • pp.1084-1088
    • /
    • 1995
  • A complete solid solution (SrLaAl1-xNixO4) between insulating SrLaAlO4 and metallic SrLaNi(Ⅲ)O4 oxides were prepared under high oxygen pressure (1.5 kbar, 800 ℃). They have tetragonal K2NiF4-type structure in all the solid solution range. Compared with lattice parameters of the same solid solution prepared under normal condition (1 bar, 1200 ℃), large decrease in the c-parameter was induced by high pressure treatment while no noticeable variation of the a-parameter was observed. Although marked changes of structural parameters, magnetic susceptibilities, and electron paramagnetic resonance spectra were consistently occurred before and after x=0.5, overall behaviors were essentially the same with those of solid solution prepared under normal condition. Such a phenomenon is explained by assuming the formation of partially filled narrow σ*x2-y2 band for x>0.5. Lattice contraction along the c-axis by high pressure treatment seems not to broaden this band. Particularly, the continuous absorption characteristic of a high free carrier concentration for x>0.5 and the absence of Ni-O in-plane stretching mode in the infrared absorption spectra supports this picture. However, the conductivities increasing with temperature for all solid solution suggest that some localization character, of probably Anderson type, remains for x>0.5.

Three-phase Transformer Model and Parameter Estimation for ATP

  • Cho Sung-Don
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.302-307
    • /
    • 2006
  • The purpose of this paper is to develop an improved three-phase transformer model for ATP and parameter estimation methods that can efficiently utilize the limited available information such as factory test reports. In this paper, improved topologically-correct duality-based models are developed for three-phase autotransformers having shell-form cores. The problem in the implementation of detailed models is the lack of complete and reliable data. Therefore, parameter estimation methods are developed to determine the parameters of a given model in cases where available information is incomplete. The transformer nameplate data is required and relative physical dimensions of the core are estimated. The models include a separate representation of each segment of the core, including hysteresis of the core, ${\lambda}-i$ saturation characteristic and core loss.

횡단가스 유동에 분사되는 액체제트의 분무특성 (Characteristic of Liquid Jet in Subsonic Cross-flow)

  • 고정빈;이관형;구자예
    • 한국분무공학회지
    • /
    • 제10권1호
    • /
    • pp.35-42
    • /
    • 2005
  • The present study has numerically and experimentally investigated the spray behavior of liquid jet injected in subsonic cross-flow. The corresponding spray characteristics are correlated with jet operating parameters. The spray dynamics are known to be distinctly different in the three regimes: the column, the ligament and the droplet regimes. The behaviors of column, penetration and breakup of liquid jet have been studied. Numerical and physical models are base on a modified KIVA code. The primary atomization is represented by a wave model base on the KH(Kelvin-Helmholtz) instability that is generated by a high interface relative velocity between the liquid and gas flows. In odor to capture the spray trajectory, CCD camera has been utilized. Numerical and experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration decreases by increasing Weber number.

  • PDF

탄소나노튜브 작동기의 이론적 해석 (Theoretical Analysis of Carbon Nanotube Actuators)

  • 박철휴;박현철;소현기;정봉부
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.927-931
    • /
    • 2005
  • Carbon nanotube actuator, working under physical conditions (in aqueous solution) and converting electrical energy into mechanical energy directly, can be a good substitute for artificial muscle. The carbon nanotube actuator simulated in this paper is an isotropic cantilever type with an adhesive tape which is sandwiched between two single-walled carbon nanotubes. For predicting the static and dynamic characteristic parameters, the analytical model for a 3 layer bimorph carbon nanotube actuator is developed by using Euler-Bernoulli beam theory. The governing equation and boundary conditions are derived from energy principles. The induced displacements of the theoretical model are presented in order to investigate the performance of the carbon nanotube actuator with different control voltages. The developed model presents invaluable means for designing and predicting the performance of carbon nanotube actuator that can be used in artificial muscle applications.

  • PDF