• 제목/요약/키워드: photovoltaic generation system

검색결과 746건 처리시간 0.027초

인터넷 웹 기반 환경에서의 태양광용 인버터 원격제어시스템 개발에 관한 고찰 (Study of Internet Web-Based Photovoltaic Inverter Remote Control System)

  • 최주엽;조경신;최익;유권종;정영석;김기현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2001
  • This paper aims at developing remote control system to control and monitor distributed various devices such as photovoltaic Inverter system through internet. TCP/IP (Transmission Control Protocol/Internet Protocol) and photovoltaic inverter system operated in a row are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time, java-environment software is constructed. Also, HelloDevice, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232C is used between controller and applied device.

  • PDF

Battery와 Electrolyzer를 이용한 태양광 발전시스템 운영 (Operation of Photovoltaic Generation System with Battery and Electrolyzer)

  • 강기혁;김윤성;응웬칸록;원동준
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1994-2000
    • /
    • 2008
  • The output power of photovoltaic(PV) generation system is strongly affected by weather conditions. To make up for the defect of solar energy, energy storages such as battery and electrolyzer are usually integrated with photovoltaic cell. This paper focuses on the way to store energy surplus with battery and electrolyzer and to provide energy with battery. Photovoltaic generation system is modeled with PV cell, DC/DC converter, DC/AC inverter, battery and electrolyzer. The operation algorithm to regulate PV output power with battery and electrolyzer is suggested. The simulation results show that battery and electrolyzer effectively cooperate with each other to compensate the fluctuation of PV generation system.

On the Use of Maximum Likelihood and Input Data Similarity to Obtain Prediction Intervals for Forecasts of Photovoltaic Power Generation

  • Fonseca Junior, Joao Gari da Silva;Oozeki, Takashi;Ohtake, Hideaki;Takashima, Takumi;Kazuhiko, Ogimoto
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1342-1348
    • /
    • 2015
  • The objective of this study is to propose a method to calculate prediction intervals for one-day-ahead hourly forecasts of photovoltaic power generation and to evaluate its performance. One year of data of two systems, representing contrasting examples of forecast’ accuracy, were used. The method is based on the maximum likelihood estimation, the similarity between the input data of future and past forecasts of photovoltaic power, and on an assumption about the distribution of the error of the forecasts. Two assumptions for the forecast error distribution were evaluated, a Laplacian and a Gaussian distribution assumption. The results show that the proposed method models well the photovoltaic power forecast error when the Laplacian distribution is used. For both systems and intervals calculated with 4 confidence levels, the intervals contained the true photovoltaic power generation in the amount near to the expected one.

중규모 태양광발전시스템 장기 실증운전 평가 (The long-term operating evaluation of the grid connected photovoltaic system)

  • 김의환;안교상;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

태양광 발전시스템의 일사량에 따른 전력 패턴 분석 (Power Pattern Analysis According to Irradiation for Photovoltaic Systems)

  • 박상준;김형석;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.46-48
    • /
    • 2009
  • This paper aims to investigate generation conditions necessary for the most efficient generation by measuring electricity power under various irradiation conditions, since the photovoltaic generation system has high costs and low efficiency. In addition, because the irradiation varies hourly, daily, monthly, and yearly, the research on the irradiation necessary for photovoltaic generation was carried out by analyzing the pattern o( Bower under various irradiation conditions. Also, after measuring the daily variations of irradiation and generation power, the monthly accumulated irradiation and monthly accumulate power which had the most generation power were investigated and the pattern of the annual generation power was analyzed. The results of this study are as follows. As for the relationship between the photovoltaic generation system and the irradiation, the generation power increased with the irradiation and when the irradiation was more than 600 $[W/m^2]$ the generation power amounted to more than 100 [Wh] as the resonable result.

  • PDF

3상 계통연계 태양광발전시스템의 운전특성 (Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System)

  • 김영철;정명웅;서기영;이현우;우준인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

독립형 소형 태양광/풍력 복합발전시스템의 출력안정화를 위한 보조 전력보상장치개발에 관한 연구 (The Auxiliary Power Compensation Unit for Stand-Alone Photovoltaic/Wind Hybrid Generation System)

  • 박세준;윤정필;강병복;윤형상;차인수;임중열
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.47-54
    • /
    • 2004
  • Photovoltaic energy and wind energy are highly dependent on the season, time and extremely intermittent energy sources. Because of these reasons, in view of the reliability the photovoltaic and the wind power generation system have many problems(energy conversion, energy storage, load control etc.) comparing with conventional power plant. In order to solve these existing problems, hybrid generation system composed of photovoltaic(500W) and wind power system(400W) was suggested. But, hybrid generation system cannot always generate stable output due to the varying weather condition. So, the auxiliary power compensation unit that uses elastic energy of spiral spring was added to hybrid generation system for the present study. It was partly confirmed that hybrid generation system was generated a stable outputs by spiral spring was continuously provided to load.

철도인프라용 태양광발전시스템 확대를 위한 기상정보 활용 발전량 예측 비교 연구 (Comparative Study to Predict Power Generation using Meteorological Information for Expansion of Photovoltaic Power Generation System for Railway Infrastructure)

  • 유복종;박찬배;이주
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.474-481
    • /
    • 2017
  • 국내에서 태양광 발전설비 설계 시 설계 단계에서의 태양광발전소의 발전량 예측은 국내 현장임에도 불구하고 PVsyst, PVWatts 등 해외 발전량 예측 프로그램과 해외 기상 자료를 이용하여 발전량을 예측하는 경우가 대부분을 차지하고 있는 실정이다. 본 논문에서는 기상정보를 활용한 발전량 예측 비교 연구를 위하여 현재 운영중인 2개 지역의 국내 태양광발전소를 대상지로 선정하였다. 발전량 예측 프로그램인 PVsyst를 활용하여 Meteonorm 7.1과 NASA-SSE의 해외 기상정보를 이용한 발전량 예측값과 국내 기상청 (Korea Meteorology Administration) 기상정보를 활용한 발전량 예측 정확성을 비교하였다. 추가적으로, 기상자료 비교 분석을 통한 발전량 예측 개선 방안을 연구하고, 최종적으로 실제 발전량과의 비교 분석을 통해 기후요소가 고려된 태양광 발전량 예측 수정 모델을 제시하였다.

Perez Model을 적용한 태양광 시스템 별 최적 설치 조건 및 최대 발전량 분석 (An Analysis of Optimal Installation Condition and Maximum Power Generation of Photovoltaic Systems Applying Perez Model)

  • 이재덕;김철환
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.683-689
    • /
    • 2012
  • Photovoltaic(PV) system is one of power generation systems. Solar light in PV system is like the fuel of the car. The quantity of electricity generation, therefore, is fully dependent on the available quantity of solar light on the system of each site. If a utility can predict the solar power generation on a planned site, it may be possible to set up an appropriate PV system there. It may be also possible to objectively evaluate the performances of existing solar systems. Based on the theories of astronomy and meteorology, in this paper, Perez model is simulated to estimate the available quantity of solar lights on the prevailed photovoltaic systems. Consequently the conditions for optimal power generation of each PV system can be analyzed. And the maximum quantity of power generation of each system can be also estimated by applying assumed efficiency of PV system. Perez model is simulated in this paper, and the result is compared with the data of the same model of Meteonorm. Simulated site is Daejeon, Korea with typical meteorological year(TMY) data of 1991~2010.

계통연계 태양광발전시스템의 제어기법 및 연계운전특성 (A control method and test results of utility interactive photovoltaic power generation systems)

  • 안교상;임희천;황인호;주형준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF