• 제목/요약/키워드: photothermal effect

검색결과 29건 처리시간 0.02초

Consideration of Temperature and Slip Correction for Photothermal Spectrometry

  • Lee, Jeonghoon
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권1호
    • /
    • pp.86-90
    • /
    • 2015
  • Temperature was considered to estimate the minimum detectable absorption coefficient of aerosol particles from photothermal spectroscopy. Light energy absorbed by subsequent emission from the aerosol results in the heating of the aerosol sample and consequently causes a temperature change as well as changes in thermodynamic parameters of the sample. This thermal effect is the basis of photothermal spectroscopy. Photothermal spectroscopy has several types of techniques depending on how the photothermal effects are detected. Photothermal interferometry traces the photothermal effect, refractive index, using an interferometer. Photoacoustic spectroscopy detects the photothermal effect, sound wave, using a microphone. In this study, it is suggested that the detection limit for photothermal spectroscopy can be influenced by the introduction of a slip correction factor when the light absorption is determined in a high temperature environment. The minimum detectable absorption coefficient depends on the density, the specific heat and the temperature, which are thermodynamic properties. Without considering the slip correction, when the temperature of the environment is 400 K, the minimum detectable absorption coefficient for photothermal interferometry increases approximately 0.3% compared to the case of 300 K. The minimum detectable absorption coefficient for photoacoustic spectroscopy decreases only 0.2% compared to the case of 300 K. Photothermal interferometry differs only 0.5% point from photoacoustic spectroscopy. Thus, it is believed that photothermal interferometry is reliably comparable to photoacoustic spectroscopy under 400 K.

Study of Optimal Conditions Affecting the Photothermal Effect and Fluorescence Characteristics of Indocyanine Green

  • Seo, Sung Hoon;Bae, Min Gyu;Park, Hyeong Ju;Ahn, Jae Sung;Lee, Joong Wook
    • Current Optics and Photonics
    • /
    • 제5권5호
    • /
    • pp.554-561
    • /
    • 2021
  • Indocyanine green (ICG) is a cyanine dye that has been used in medical diagnostics based on fluorescence imaging, and in medical therapy based on the photothermal effect. It is important to systematically understand the photothermal effect and fluorescence characteristics of ICG simultaneously. By varying a number of conditions such as laser power density, laser irradiation wavelength, concentration of ICG solution, and exposure time of laser irradiation, the intensity properties of fluorescence and the temperature change induced by the photothermal effect are measured simultaneously using a charge-coupled-device camera and a thermal-imaging camera. The optimal conditions for maximizing the photothermal effect are determined, while maintaining a relatively long lifetime and high efficiency of the fluorescence for fluorescence imaging. When the concentration of ICG is approximately 50 ㎍/ml and the laser power density exceeds 1.5 W/cm2, the fluorescence lifetime is the longest and the temperature induced by the photothermal effect rapidly increases, exceeding the critical temperature sufficient to damage human cells and tissues. The findings provide useful insight into the realization of effective photothermal therapy, while also specifying the site to be treated and enabling real-time treatment monitoring.

향상된 광열 효과를 갖는 카르복실화된 환원 그래핀옥사이드-골드나노막대 나노복합체의 제조 및 특성 분석 (Preparation and Characterization of Reduced Graphene Oxide with Carboxyl Groups-Gold Nanorod Nanocomposite with Improved Photothermal Effect)

  • 이승화;김소연
    • 공업화학
    • /
    • 제32권3호
    • /
    • pp.312-319
    • /
    • 2021
  • 광열 치료(photothermal therapy)란 빛을 조사하여 열을 발생시킴으로써 정상세포보다 열에 약한 비정상 세포, 특히 암세포를 선택적으로 괴사시키는 치료법이다. 본 연구에서는 광열 치료를 위한 카르복실화된 환원 그래핀옥사이드(reduced graphene oxide with carboxyl groups, CRGO)-골드나노막대(gold nanorod, AuNR) 나노복합체를 합성하고자 하였다. 이를 위해 그래핀옥사이드(graphene oxide, GO)를 고온에서 선택적으로 환원, 박리하여 CRGO를 합성하였고, AgNO3의 양에 따라 AuNR의 길이를 조절하여 880 nm에서 강한 흡광 특성을 나타내는 AuNR를 합성하여 광열 인자로 사용하였다. 일반적인 방법으로 환원된 RGO에 비해 CRGO에 상대적으로 많은 카르복실기가 결합되어 있음을 FT-IR, 열 중량 분석 및 형광 분석을 통해 확인하였다. 또한, RGO에 비해 많은 carboxyl group이 결합된 CRGO는 수용액상에서 우수한 안정성을 나타내었다. 정전기적 상호작용을 통해 합성된 CRGO-AuNR 나노복합체는 약 317 nm의 균일한 크기와 좁은 크기 분포를 보였다. CRGO-AuNR 나노복합체는 두 가지 광열 인자인 CRGO와 AuNR의 synergistic effect로 인하여 조직 투과도가 우수한 근적외선 880 nm 레이저의 조사에 의한 광열 효과가 AuNR보다 2배 이상 향상 되는 것을 확인하였다. 또한, 광열 효과에 의한 암세포 독성 분석 결과, CRGO-AuNR 나노복합체가 가장 우수한 세포 독성 특성을 나타내었다. 따라서 CRGO-AuNR 나노복합체는 안정된 분산성과 향상된 광열 효과를 기반으로 항암 광열 요법 분야에 응용될 수 있을 것으로 기대된다.

355nm UV 레이저 가공에 의한 폴리이미드의 광화학적 및 광열적 어블레이션에 관한 연구 (Photothermal and Photochemical Investigation on Laser Ablation of the Polyimide by 355nm UV Laser Processing)

  • 오재용;신보성
    • 한국정밀공학회지
    • /
    • 제24권4호
    • /
    • pp.147-152
    • /
    • 2007
  • UV laser ablation of polyimide is a combination of photochemical and photothermal mechanism. Photochemical mechanism is that molecular bonds are broken by photon energy and photothermal is evaporation and melt expulsion. When the laser processing, the etching depth needs to be calculated for prediction of processing result. In this paper, in order to predict the laser etching depth of polyimide by UV laser with the wavelength of 355nm, the theoretical model which includes both the photothermal and the photochemical effect was introduced. The model parameters were obtained by comparing with experimental results. The 3rd harmonic $Nd:YVO_4$ laser system was used in the experiment. From these experimental and theoretical results, the laser ablation of a polyimide was verified to achieve the highest quality microstructure.

Critical Enhancement of Photothermal Effect by Integrated Nanocomposites of Gold Nanorods and Iron Oxide on Graphene Oxide

  • Yun, Kum-Hee;Seo, Sun-Hwa;Kim, Bo-Mi;Joe, Ara;Han, Hyo-Won;Kim, Jong-Young;Jang, Eue-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2795-2799
    • /
    • 2013
  • Irradiation of gold nanorods (GNRs) with laser light corresponding to the longitudinal surface plasmon oscillation results in rapid conversion of electromagnetic energy into heat, a phenomenon commonly known as the photothermal effect of GNRs. Herein, we propose a facile strategy for increasing the photothermal conversion efficiency of GNRs by integration to form graphene oxide (GO) nanocomposites. Moreover, conjugation of iron oxide (IO) with the GO-GNR nanohybrid allowed magnetic enrichment at a specific target site and the separated GO-IO-GNR assembly was rapidly heated by laser irradiation. The present GO-IO-GNR nanocomposites hold great promise for application in various biomedical fields, including surface enhanced Raman spectroscopy imaging, photoacoustic tomography imaging, magnetic resonance imaging, and photothermal cancer therapy.

금 나노입자의 광열효과를 이용한 온열화장품 개발 (Development of Thermo-Cosmetics Using Photothermal Effect of Gold Nanoparticles)

  • 이재열;김보미;박세호;최요한;심규동;문성배;장의순;양선아;지광환
    • 대한화장품학회지
    • /
    • 제41권1호
    • /
    • pp.27-34
    • /
    • 2015
  • 나노입자의 응용은 1970년대부터 발전되어 왔다. 금속 나노입자에 빛을 조사하면 나노입자 표면에서 플라즈몬 공명(SPR, surface plasmon resonance)을 일으킨다. SPR 효과는 금속표면에 입사한 빛에너지에 의해 전자가 여기하며 공명을 일으켜 진동을 발생시키는 현상을 말한다. 여기 된 전자들이 금속원자들과 충돌을 일으키며 열에너지로 전환될 수 있는데 이를 금속의 광열효과(photothermal effect)라고 한다. 우리는 광열 효과를 이용하여 온열 화장품의 개발 가능성을 제시하고자 한다. 온열 화장품의 개발을 위해 생체 독성이 적은 금 나노입자를 선택하여 광열 효과에 있어서의 세포 생체적합성과 열효율을 살펴보았다. 금 나노입자의 합성 상태는 금 나노입자가 갖는 독특한 흡광 스펙트럼으로 확인하였으며, 금 나노입자의 농도는 원자 흡광분석기로 측정하였다. 세포의 독성평가는 MTT assay와 이중 염색법을 사용하였으며, 금 나노입자의 광열 효과는 제논 램프를 광원으로 하여 금 나노입자의 농도의 증가에 따른 광열 효과증대를 적외선-열화상 카메라로 확인하였다. 금 나노입자의 광열 효과를 온열 화장품에 적용한다면 한대 지방의 기후, 또는 겨울철에 태양 에너지를 열에너지로 전환시켜 피부에 손실된 열을 공급, 피부온도 유지에 도움이 되고 피부건강에 긍정적 효과를 주리라 사료된다.

355nm UV 레이저를 이용한 구리 박판 가공 시 어블레이션에 관한 연구 (A Study on Laser Ablation of Copper Thin Foil by 355nm UV Laser Processing)

  • 오재용;신보성
    • 한국정밀공학회지
    • /
    • 제24권2호
    • /
    • pp.134-139
    • /
    • 2007
  • Usually nanosecond pulsed laser processing of metal is mainly affected by the thermal ablation. Many studies of the theoretical analysis and modeling to predict the laser ablation of metal are suggested on the basis of the photothermal mechanism at higher laser fluence. In this paper, we investigate the etching depth and laser fluence of laser ablation of copper foils and propose the simplified SSB Model(Srinivasan-Smrtic-Babu model) to study the photothermal effect of nanosecond pulsed laser ablation. The experimental results show that the photothermal ablation of the 355nm DPSS $NdYVO_{4}$ laser is useful to process the copper thin foils.

탄소계 광발열 소재 혼입 버블시트를 적용한 콘크리트의 양생온도 특성 (Curing Temperature of Concrete Using Bubble Sheet with Carbon-based Photothermal Materials)

  • 이승민;이현직;백성진;한준희;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.45-46
    • /
    • 2023
  • This study examined the curing temperature of concrete with a photothermal insulation sheet to shorten the curing time of concrete as part of construction cost and period reduction. According to the experiment results, the heating performance effect is confirmed through the temperature difference between photothermal insulation sheet and bubble sheet. And it has a high curing temperature in the order of bubble sheet (photo heating material B) > bubble sheet (photo heating material A) > bubble sheet on same layers.

  • PDF

재료의 열확산계수 결정을 위한 광열복사법의 이론적 연구 (A Theoretical Study of Photothermal Pulsed Radiometry Method for the Thermal Diffusivity Measurement)

  • 육형규;유재석;김현정;이광재
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.27-34
    • /
    • 2005
  • We analyze in detail axially symmetric theoretical study for the photothermal pulsed radiometry of a cylindrical model. The theoretical solutions describe the transient infrared radiation from the sample heated by short-duration pulsed heating. In the conventional transmission radiometry technique, the excitation source and the detector are on opposite sides of the sample, otherwise in the new single ended radiometry technique, the excitation source and the detector are on same sides of the sample. The analytical solution described for photothermal radiometry in this study would not need to cut or polish samples to measure the thermal diffusivity. Therefore the radial area and axial thickness of samples are not limited. The effects of excitation pulse duration and the area of heat source are discussed.