• Title/Summary/Keyword: photosensor

Search Result 67, Processing Time 0.023 seconds

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.

Importance of The Location of The Negative-charged Counter-ion against The Protonated Schiff Base on The Chromophore Configuration of pharaonis Phoborhodopsin

  • Shimono, Kazumi;Ikeura, Yukako;Sudo, Yuki;Iwamoto, Masayuki;Kamo, Naoki
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.302-304
    • /
    • 2002
  • pharaonis phoborhodopsin (ppR), a photophobic sensor of haloalkaliphilic bacteria, Natronobacterium phar-aonis, has retinal as a chromophore covalently bound to Lys in G-helix via a protonated Schiff base (PSB), as is the same as bacteriorhodopsin (bR). For ppR, the corresponding counter-ion is Asp residue (Asp75) located in C-helix. Here we investigated the influence of the protonated state of this counter-ion and its location on the chromophore configuration. Under alkaline condition, the chromophore configuration of D75E mutant was analyzed by HPLC. D75E had a much larger content of 13-cis isomer: the ratio of 13-cis to all-trans was 6:4 while the wild-type had this ratio of 1 :9. On the other hand, under acidic condition where Glu was associated, D75E had no 13-cis retinal isomer. Mutants whose Asp75 was replaced by neutral amino acids (D75N and D75Q) did not contain 13-cis retinal. Furthermore, retinal isomer compositions and the change in the visible ab- sorption spectra (indicating the dissociation state of Glu75) were measured under varying pH, and these were almost the same dependencies. These results indicate that an important factor determining the 13-cis isomer content is the presence of negative charge of the counter-ion against PSB, but not the size of this residue. Com- parison between the wild-type and D75E in alkaline solutions indicates the influence of the location of the counter-ion.

  • PDF

A Design of Heart Rate Feedback Controller for the Regimen of Physical Activity of the Patient with Coronary Artery Disease (관상동맥질환자의 운동요법을 위한 심장 박동궤환조절기의 설계)

  • 김진일;박종국
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.23-30
    • /
    • 1982
  • The regimen of physical activity of the patient with coronary artery disease requires that he should not overshoot the prescribed heart rate based on his age, health and fuctional status of the heart during his exercise. The step input of work load, however, involves a great danger of overshooting. The purpose of this study was to desigil a system that makes it passible for a subject to check the overshooting. This system shows on tile H.R-meter, the amplified and filtered heart-rate signal of the subject received by the photosensor on his earlobe, puts it in the lead coinpensational circuit where it is conpared with the reference input signal(=the presfribed heart rate). The output of the lead compensational circuit works the aull meter. By means of this null meter, the subject knows whether he is overshooting the prescribed heart rate or not. He can continue the natl meter needle at the'Zero'position through the control of the speed of pedaling of the bicycle ergometer, An experimental test, made on eight men and four women in healthy condition, showed that 91. 7% of them vlaintained the stable heart rate and that the overshooting of the desired heart rate did not exceed $\pm$2BPM. According to the result of this experiment, since the heart rate feedback controller makes it possible for the subject to take the prescribed exercise based not on the work load but on the heart rate which incidentally is inexpensive, it can be made use of as the instrument for the regimen of pflysical activity by the patient with coronary artery disease.

  • PDF

Al Doping Effect of Pd/TiO2 for Improved Hydrogen Detection (수소 감지 성능 향상을 위한 Pd/TiO2 분말에서의 Al 도핑 효과)

  • Lee, Yeongan;Seo, Hyungtak
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.207-210
    • /
    • 2014
  • $TiO_2$ oxide semiconductor is being widely studied in various applications such as photocatalyst and photosensor. Pd/$TiO_2$ gas sensor is mainly used to detect $H_2$, CO and ethanol. This study focus on increasing hydrogen detection ability of Pd/$TiO_2$ in room temperature through Al-doping. Pd/$TiO_2$ was fabricated by the hydrothermal method. Contacting to Aluminum (Al) foil led to Al doping effect in Pd/$TiO_2$ by thermal diffusion and enhanced hydrogen sensing response. $TiO_2$ nanoparticles were sized at ~30 nm of diameter from scanning electron microscope (SEM) and maintained anatase crystal structure after Al doping from X-ray diffraction analysis. Presence of Al in $TiO_2$ was confirmed by X-ray photoelectron spectroscopy at 73 eV. SEM-energy dispersive spectroscopy measurement also confirmed 2 wt% Al in Pd/$TiO_2$ bulk. The gas sensing test was performed with $O_2$, $N_2$ and $H_2$ gas ambient. Pd/Al-doped $TiO_2$ did not response $O_2$ and $N_2$ gas in vacuum except $H_2$. Finally, the normalized resistance ratio ($R_{H2on}/R_{H2off}$) of Pd/Al-doped $TiO_2$ increases about 80% compared to Pd/$TiO_2$.

Design of Filter to Reject Motion Artifacts of PPG Signal Using Multiwave Optical Source (다파장 광원을 이용한 광용적 맥파의 동잡음 제거 필터 설계)

  • Park, Heejung;Nam, Jaehyun;Lee, Juwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • This study is proposed the novel PPG sensor device and the signal processing method to replace the acceleration sensor that is used to reject motion artifacts contained in photoplethysmography(PPG). The proposed method is to reject motion artifacts by an adaptive filter based on the estimated motion artifact by using a blue LED light. To evaluate the performance of the proposed method experimentally, We did design a novel sensor consisted of blue/red LEDs and photo-sensor and implemented, and then rejected the motion artifacts by using an adaptive filter and the implemented sensor. In the results of the experiments, it is shown that the proposed sensor device and signal processing can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the SNR was 4.5 times of moving average filter. According to the experimental results, the proposed method can be applied to design a low-cost device.

Development of Sensitivity-Enhanced Detector using Pixelization of Block Scintillator with 3D Laser Engraving (3차원 레이저 각인으로 블록형 섬광체의 픽셀형화를 통한 민감도 향상 검출기 개발)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.313-318
    • /
    • 2019
  • To improve the sensitivity, a detector using a block scintillator was developed. In the pixelated scintillator, a reflector is located between pixels to move the light generated from the scintillator to the photosensor as much as possible, and sensitivity loss occurs in the reflector portion. In order to improve the sensitivity and to have the characteristics of the pixelated scintillator, the block scintillator was processed into a scintillator in pixel form through three-dimensional laser engraving. The energy spectra and energy resolution of each pixel were measured, and sensitivity analysis of block and pixel scintillator was performed through GATE simulation. The measured global energy resolution was 20.7%, and the sensitivity was 18.5% higher than that of the pixel scintillator. When this detector is applied to imaging devices such as gamma camera and positron emission tomography, it will be possible to shorten the imaging time and reduce the dose of patient by using less radiation source.

Digital Position Measurement with MLPE of PET detector using a Small Number of Photosensors (적은 수의 광센서를 사용한 PET 검출기의 최대우도함수를 적용한 디지털 위치 측정)

  • Kang, Seunghun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2022
  • A detector using a small number of photosensors was designed, and the position of a scintillation pixel that interacted with gamma rays through a maximum likelihood position estimation(MLPE) was measured as a digital position. For this purpose, simulation was performed using DETECT2000, which can simulate the movement of light within the scintillator, and the accuracy of position measurement was evaluated. A detector was configured using a 6 × 6 scintillation pixel array and 4 photosensors, and a gamma ray event was generated at the center of each scintillation pixel to create a look-up table through the ratio of acquired light. The gamma-ray event generated at the new position was applied as the input value of the MLPE, and the positiion of the scintillation pixel was converted into a digital positiion after comparison with the look-up table. All scintillation pixels were evaluated, and as a result, a high accuracy of 99.1% was obtained. When this method is applied to the currently usesd system, it is concidered that the process of determining the position of the scintillation pixel will be simplified.

Effects of Blended TIPS-pentacene:ph-BTBT-10 Organic Semiconductors on the Photoresponse Characteristics of Organic Field-effect Transistors (TIPS-pentacene:ph-BTBT-10 혼합 유기반도체가 유기전계효과트랜지스터 광반응 특성에 미치는 영향)

  • Chae Min Park;Eun Kwang Lee
    • Clean Technology
    • /
    • v.30 no.1
    • /
    • pp.13-22
    • /
    • 2024
  • In this study, blended 6,13-Bis(triisopropylsilylethynyl)pentacene (TP):2-Decyl-7-phenyl[1]benzothieno[3,2-b][1] benzothiophene (BT):Poly styrene (PS) TFT at different ratios were explored for their potential application as light absorption sensors. Due to the mixing of BT, both off current reduction and on/off ratio improvement were achieved at the same time. In particular, the TP:BT:PS (1:0.25:1 w/w) sample showed excellent light absorption characteristics, which proved that it is possible to manufacture a high-performance light absorption device. Through analysis of the crystal structure and electrical properties of the various mixing ratios, it was confirmed that the TP:BT:PS (1:0.25:1 w/w) sample was optimal. The results of this study outline the expected effects of this innovation not only for the development of light absorption devices but also for the development of mixed organic semiconductor (OSC) optoelectronic systems. Through this study, the potential to create a multipurpose platform that overcomes the limitations of using a single OSC and the potential to fabricate a high-performance OSC TFT with a fine-tuned optical response were confirmed.

Design of movable Tracking System using CDS Type Sensor (CDS센서를 이용한 이동 가능형 태양추적시스템 설계)

  • Sim, Myung-Gyu;Ji, Un-Ho;Chun, Soon-Yong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.6-11
    • /
    • 2010
  • Amount of power generated from solar photovoltaic can vary according to solar flux of sunlight due to nature of solar cell panel, and an angle that the sun and the surface of cell makes brings difference in amount of power generation. Solar flux is decided by location of surface of the Earth that is classified into longitude and latitude, but on the other hand, an angle that the sung and the surface of cell makes can be changed by changing the angle of a solar power generation device at the fixed location. A method of changing the angle of a solar power generation device as a measure for improving practical power generation efficiency. and studies about a solar tracking device for this are in active. This study conducted a research on a solar tracking system for improvement of solar power generation efficiency. A solar tracking system of this study is composed of a sensor part to confirm a location of the sun with a semiconductor photosensor using the photo conductive effect, and it analyzed output signal of a sensor by using microprocessor and it produced a control signal of driving part for tracking the sun. A solar power generator (25W) was produced to analyze performance of a solar tracking system and usefulness of a solar tracking device that was designed and produced in this study was confirmed through experiments.

Optical Current Sensors with Improved Reliability using an Integrated-Optic Reflective Interferometer (반사형 간섭계를 이용하여 신뢰성을 향상시킨 광전류센서)

  • Kim, Sung-Moon;Chu, Woo-Sung;Oh, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.17-23
    • /
    • 2017
  • Optical current sensors are suitable for operation in high voltage and high current environments such as power plants due to they are not affected by electromagnetic interference and have excellent insulation characteristics. However, as they operate in a harsh environment such as large temperature fluctuation and mechanical vibration, high reliability of the sensor is required. Therefore, many groups have been working on enhancing the reliability. In this work, an integrated optical current sensor incorporating polarization-rotated reflection interferometer is proposed. By integrating various optical components on a single chip, the sensor exhibits enhanced stability as well as the solution for low-cost optical sensors. Using this, we performed the characterization for the actual field application. By using a large power source, the current of 0.3 kA~36 kA was applied to the photosensor and the linear operation characteristics were observed. The error of the sensor was within $0{\pm}.5%$. Even when operating for a long time, the error range of the sensor was kept within $0{\pm}.5%$. In addition, the measurement of the frequency response over the range of 60 Hz to 10 kHz has confirmed that the 3-dB frequency band of the proposed OCT is well over 10 kHz.