• 제목/요약/키워드: photoelastic model

검색결과 74건 처리시간 0.024초

광탄성 프린지 위상 이동법을 이용한 곡선보평판의 응력 해석 (Stress Analysis of a Curved Beam Plate by using Photoelastic Fringe Phase Shifing Technique)

  • 백태현;김명수;김수일
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2313-2318
    • /
    • 2000
  • The method of photoelasticity allows one to obtain principal stress differences and principal stress directions in a photoelastic model. In the classical approach, the photoelastic parameters are measured manually point by point. This is time consuming and requires skill in the identification and measurement of photoelastic data. Fringe phase shifting method has been recently developed and widely used to measure and analyze fringe data in photo-mechanics. This paper presents the test results of photoelastic fringe phase shifting method for the stress analysis of a curved beam plate. The technique used here requires four phase stepped photoelastic images obtained from a circular polariscope by rotating the analyzer at 0˚, 45˚, 90˚ and 135˚. Experimental results are compared with those of ANSYS and calculated by the simple beam theory. Good agreement among the results can be observed.

치관보철물(齒冠補綴物)의 인접변연부위(隣接邊緣部位)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析) (Photoelastic Stress Analysis of Proximal Margins in Dental Restorations)

  • 임정규
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.37-47
    • /
    • 1980
  • The purpose of this study was to investigate the stresses in different proximal margins and to measure, quantitatively, the effect of different modifications in the design of preparations on the stresses using two-dimensional photoelasticity. Photoelastic stress analysis is based on the phenomenon, exhibited by most transparent solids, of becoming birefringent, or doubly refracting, when strained. Two birefringent materials were used in this study, PSM-1 and PSM-5 in .standard sheet ($10'{\times}10'{\times}\frac{1}{4}'$ thickness), PSM-1(polyester) was used for constructing the substructure, and PSM-5(epoxy resin) was used in making the restorations to be investigated. Two birefringent materials were used in the construction of composite photoelastic model. Seven variable models were constructed. The peripheral dimensions of all model were constant and the models represent an occlusomesial section of a lower posterior molar. Model 1 represents the knife edge margin (shoulderless), Model 2 represents the chamfer, Model 3 represents a rounded shoulder(no sharp angle between the axial wall and gingival floor), Model 4 represents a flat shoulder (axial wall is a $90^{\circ}$ angle to the gingival wall), Model 5 represents $+15^{\circ}$ angulation, Model 6 has a $-15^{\circ}$ angulation, and Model 7 is the same as Model 4 except that it has a $45^{\circ}$ bevel. Improved artificial stone was used to represent dental cement in luting the composite photoelastic model. Static loading procedures(100 pounds) were used at preplanned sites. The results were as follows; 1. The stresses in the proximal portion of all tested models were compressive in nature when the proximal shoulders were loaded vertically on the same proximal marginal ridge. 2. The round and chamfered preparations were the optimum designs in proximoocclusal restorations. They showed the lowest stress concentration factor, i.e. 2.16 and 2.23, respectively. The knife edged shoulder had the highest value, K=5.39. Round type shoulder geometry experiments reduced the stress concentration factor (S.C.F.) 3. The gingival portion of proximal shoulder geometry was a critical location for stress concentration.

  • PDF

트랩도어 하강이 일어나는 모형 입자 입상체에서 광탄성 측정 기법을 이용한 흙 아치 구조의 변화 조사 (Investigation of the Change of Soil Arch Structure in Model Particle Assembly Subjected to Displacing Trapdoor via Photoelastic Measurement Technique)

  • 신상영;정영훈;김태식
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.31-40
    • /
    • 2016
  • 트랩도어 하강이 일어나는 토체 내부에서 발생하는 흙 아치 구조의 변화를 관찰하기 위해서 광탄성 측정 기법을 이용하여 입상체의 다양한 거동을 관찰하였다. 광탄성 반응 재료로 코팅된 원주형 모형 입자를 적층하여 입상체를 구성하였다. 광탄성 기법을 이용하여 입상체 내부에서 발생하는 입자 간 접촉력 전달 구조의 변화를 촬영하여 관찰하였으며 이를 입상체 하부 로드셀에서 측정된 압력 변화 및 내부 활동면의 변화 양상과 비교 분석하였다. 트랩도어 하강 초기에 형성된 흙 아치 구조는 하강이 지속되면 붕괴되지만 다시 확장된 아치 구조가 새롭게 형성되었다. 트랩도어 하강 초기에 일치하였던 흙 아치 구조의 경계면과 활동면은 트랩도어 하강이 진행되면서 활동면이 포함된 영역이 접촉력을 잃은 영역 내부에 포함되었다.

3종류의 구치부 Uprighting Spring의 초기응력분포에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION BY 3 TYPES OF MOLAR UPRIGHITNG SPRING)

  • 전윤식
    • 대한치과교정학회지
    • /
    • 제24권3호
    • /
    • pp.709-719
    • /
    • 1994
  • The aim of this investigation was to identify which suing is more suitable for uprighting of the 30 degree inclined lower second molar in different situations. Between four different molar uprighting springs which were A, B, C type and T-loop spring, the author tested T-loop suing as a control material and the other springs were experimental group. Each spring was fabricated from .017' $\times$ .025' TMA wire and preactivated with 40 degree tip-back bend. Stabilizing unit included from the lower right central incisor to the lower right second premolar which were made by acrylic resin. The photoelastic overview of the lower right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows. 1. Higher concentration of compression can be seen clearly at the distal curvature than the mesial of the lower second molar when A type uprighting spring was applied, which can be used as a space regainer. 2. Higher level compression was presented at the mesial root apex area than the distal of the lower second molar in B type uprighting spring, which can be used as a space closer. 3. Areas of higher compression and tension were observed about the mesial and distal root of the lower second moalr than A and B type in C type uprighting spring, which can be used as a partial space regainer.

  • PDF

이종재료의 진전 계면 균열에 대한 동적 광탄성 실험법 (Dynamic Photoelastic Experimental Method for Propagating Interfacial Crack of Bimaterials)

  • 신동철;황재석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.292-297
    • /
    • 2000
  • In this research, the dynamic photoelastic experimental hybrid method for bimaterial is introduced. Dynamic biaxial loading device is developed, its strain rate is 31.637 s-1 and its maximum impact load is 20 ton. Manufactured methods for model of the dynamic photoelastic experiment for bimaterial are suggested. They are bonding method(bonding material: AW106, PC-1) and molding method. In the bonding method, residual stress is not occurred in the manufactured bimaterial. Crack is propagated along the interface or sometimes deviated from the interface. While in the molding method, residual stress is occurred in the manufactured bimaterial. Crack is always deviated from the interface and propagated in the epoxy region(softer materila). In order to propagate with constant velocity along the interface of bimaterial with arbitrary stiffer material, edge crack should be located along the interface of the acute angle side of the softer material in the bimaterial.

  • PDF

하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION)

  • 조혜원;김난영;김유리
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

투과형 광탄성 실험법에 의한 지능성 FRP의 파괴지연 효과에 관한 연구 (A Study on the Effect of Fracture Delay of Intelligent FRP by Transparent Photoelastic Experimental Method)

  • 이효재;황재석
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.1904-1911
    • /
    • 1999
  • The most effective material in the shape memory alloy(SMA) is the TiNi alloy, because its shape recovery characteristics are very excellent. We molded the composite material with shape memory function. The fiber of it is $Ti_{50}-Ni_{50}$ shape memory alloy and matrix of it is epoxy resin(Araldite B41, Hardner HT903. Ciba Geigy), its adhesive and optical sensitivity are very excellent. It was assured that the composite material could be used as model material of photoelastic experiment for intelligent materials or structures. In this research, the composite material with shape memory function is used as model material of photoelastic experiment. Photoelastic experimental hybrid method is developed in this research, it is assured that it is useful on the obtaining stress intensity factor and the separation of stress components from only isochromatic data. The measuring method of stress intensity factor of intelligent material by photoelastic experiment is introduced. In the mode I state, we can know that stress intensity factors are decreased more than 50% of stress intensity factor of room temperature when temperature of fiber is greater than 4$0^{\circ}C$, prestrain greater than 5% and fiber volume ratio greater than 0.42% and that stress intensity factors are decreased by 100% when fiber volume ratio is greater than 0.84%, prestrain greater than 5% and temperature greater than 60 $^{\circ}C$.

주 연결장치의 설계변화에 따른 하악 유리단 국소의치의 광탄성 응력 분석에 관한 연구 (A PHOTOELASTIC STUDY ON THE STRESS ANALYSIS UNDER MADIBULAR DISTAL-EXTENSION REMOVABLE PARTIAL DENTURE WITH DIFFERENT DESIGN OF THE MAJOR CONNECTOR)

  • 이규칠;계기성
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.177-194
    • /
    • 1991
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a distal extension removable partial dentures with three kinds of mandibular major connectors, that is, lingual bar, linguoplate, and swing-lock attachment. A photoelastic model was made of the epoxy resin(PC-1) and hardener(PCH-1) and coated with plastic cement-1 (PC-1) at the lingual surface of the epoxy model and set with three kinds of chrome-cobalt removable partial dentures. A bilateral vertical load of 15kg to the middle portion of the metal bar crossing both the first molars of the right and the left, and a unilateral vertical load of 12.5kg to the right first molar were applied with the use of specially designed loading device and the reflective circular polariscope was used to analyze the photoelastic model under each condition. The following results were obtained : 1. When the bilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 2. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 3. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the termial abutment or adjacent teeth on the non-loaded side showed the least stress distribution in case of swing-lock attachment. 4. When the bilateral vertical load and the unilateral vertical load were applied the swing-lock attachment showed the mildest uniform stress distribution on the edentulous area and the alveolar bone around the abutment teeth.

  • PDF

체간 위치가 하요추부의 응력상태와 척추분리증에 미치는 영향 (I) -하요추부의 응력 상태 측정용 광탄성 실험 모델 재료개발과 장치개발- (The Effect of Trunk Position on the Stress Distribution of Low-back and on the Spondylolisis (I) -Development on the Photoelastic Experimental Model and Device for the Stress Analysis of Low-Lumbar Spine-)

  • 황재석;최영철;안면환;권재도;최선호
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.723-736
    • /
    • 1992
  • 본 연구에서는 복압력(abdominal pressure) 및 복근(abdominal musles)만을 제외(하중의 계산시 이들의 역활을 포함하였다.) 한 요추골 운동에 관계하는 모든 역 학적 요소를 포함시키고 해부학적으로 매우 충실한 실험용 광탄성 모델과 하중장치를 개발하여, 이러한 모델과 하중장치의 유효성을 임상의학적으로 규명 하는것을 본 연구 의 목적으로 한다.

가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析) (Photoelastic Stress Analysis of Fixed Partial Dentures)

  • 조원행
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF