• Title/Summary/Keyword: photo-detector

Search Result 196, Processing Time 0.029 seconds

Radionuclide concentrations in agricultural soil and lifetime cancer risk due to gamma radioactivity in district Swabi, KPK, Pakistan

  • Umair Azeem;Hannan Younis;Niamat ullah;Khurram Mehboob;Muhammad Ajaz;Mushtaq Ali;Abdullah Hidayat;Wazir Muhammad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.207-215
    • /
    • 2024
  • This study focuses on measuring the levels of naturally occurring radioactivity in the soil of Swabi, Khyber Pakhtunkhwa, Pakistan, as well as the associated health hazard. Thirty (30) soil samples were collected from various locations and analyzed for 226Ra, 232Th, and 40K radioactivity levels using a High Purity Germanium detector (HPGe) gamma-ray spectrometer with a photo-peak efficiency of approximately 52.3%. The average values obtained for these radionuclides are 35.6 ± 5.7 Bqkg-1, 47 ± 12.5 Bqkg-1, and 877 ± 153 Bqkg-1, respectively. The level of 232Th is slightly higher and 40K is 2.2 times higher than the internationally recommended limit of 30 Bqkg-1 and 400 Bqkg-1, respectively. Various parameters were calculated based on the results obtained, including Radium Equivalent (Raeq), External Hazard (Hex), Absorbed Dose Rate (D), Annual Gonadal Equivalent Dose (AGDE), Annual Effective Dose Rate, and Excess Lifetime Cancer Risk (ELCR), which are 170.3 ± 24 Bqkg-1, 0.46 ± 0.06 Bqkg-1, 81.4 ± 2.04 nGy h-1, 582 ± 78.08 µSvy-1, 99.8 ± 13.5 µSv Gy-1, and 0.349 ± 0.04, respectively. These values are below the limits recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2002. This study highlights the potential radiation threats associated with natural radioactivity levels in the soil of Swabi and provides valuable information for public health and safety.

The Scattering Beam Measurement of the RBC and the Fabrication of the Micro Cell Biochip (적혈구의 산란빔 측정과 마이크로 세포 분석 바이오칩 제작)

  • Byun, In Soo;Kwon, Ki Jin;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • Next future, The bio technology will be a rapidly developing. This paper is the scattering beam measurement of the red blood cell (RBC) and the fabrication of the micro cell biochip using the bio micro electro mechanical system (Bio-MEMS) process technology. The Major process method of Bio-MEMS technology was used the buffered oxide etchant (BOE), electro chemical discharge (ECD) and ultraviolet sensitive adhesives (UVSA). All experiments were the 10 times according to the process conditions. The experiment and research are required the ultraviolet expose, the micro fluid current, the cell control and the measurement of the output voltage Vpp (peak to peak) waveform by scattering angles. The transmitting and receiving of the laser beam was used the single mode optical fiber. The principles of the optical properties are as follows. The red blood cells were injected into the micro channel. The single mode optical fiber was inserting in the guide channel. The He-Ne laser beam was focusing in the single mode optical fiber. The transmission He-Ne laser beam is irradiating to the red blood cells. The manufactured guide channel consists of the four inputs and the four outputs. The red blood cell was allowed with the cylinder pump. The output voltage Vpp waveform of the scattering beam was measured with a photo detector. The receiving angle of the output optical fiber is $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$. The magnitude of the output voltage Vpp waveform was measured in the decrease according to increase of the reception angles. The difference of the output voltage Vpp waveform is due differences of the light transmittance of the red blood cells.

A Study on Qualitative and Quantitative Analysis of Major ingredients in Scutellariae radix (황금(Scutellariae radix)의 주요 성분의 정성 및 정량분석에 관한 연구)

  • Rhee, Jae-Seong;Woo, Eun Ran;Kim, Nam-Hyuk;Lee, Eun-Ju;An, Duk-Kyun;Lee, Je-Hyun;Park, Seong Kyu;Park, Ho-Koon
    • Analytical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.91-104
    • /
    • 1997
  • Scutellariae radix has been used on the control of body fever as oriental medicine for thousand years. Analytical aspect for the main components of Scutellariae radix was set up improving sensitivity and resolution. The analysis of 3 different flavonoids present in Scutellariae radix-baicalin, baicalein, wogonin-was conducted by means of high performance liquid chromatography with ODS reverse phase column in conjunction with a Photo Diode Array UV detector(280nm) at $40^{\circ}C$. Mobile phase was carried out at 1mL/min, composed of acetonitrile and 0.1M phosphoric acid in the form of a gradient method. Under these circumstances the retention time for baicalin, baicalein, wogonin was 7.65, 11.65 and 14.12 minutes respectively. As a result for the efficiency on extraction of active ingredients with proposed analytical process according to it's growing districts, Sunchang in Junbuk for baicalin and Bulkyo in, Junnam for bicalein and wogonin have shown the best results. Even the extraction at room temperature was satisfactory. Among acids, 0.1M acetic acid revealed the best achievements. The mixture of acetonitrile and 0.2M phosphoric acid(75:25) has been shown the best efficiency as well as stability for the extraction of active ingredients.

  • PDF

Analysis of Subwavelength Metal Hole Array Structure for the Enhancement of Quantum Dot Infrared Photodetectors

  • Ha, Jae-Du;Hwang, Jeong-U;Gang, Sang-U;No, Sam-Gyu;Lee, Sang-Jun;Kim, Jong-Su;Krishna, Sanjay;Urbas, Augustine;Ku, Zahyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.334-334
    • /
    • 2013
  • In the past decade, the infrared detectors based on intersubband transition in quantum dots (QDs) have attracted much attention due to lower dark currents and increased lifetimes, which are in turn due a three-dimensional confinement and a reduction of scattering, respectively. In parallel, focal plane array development for infrared imaging has proceeded from the first to third generations (linear arrays, 2D arrays for staring systems, and large format with enhanced capabilities, respectively). For a step further towards the next generation of FPAs, it is envisioned that a two-dimensional metal hole array (2D-MHA) structures will improve the FPA structure by enhancing the coupling to photodetectors via local field engineering, and will enable wavelength filtering. In regard to the improved performance at certain wavelengths, it is worth pointing out the structural difference between previous 2D-MHA integrated front-illuminated single pixel devices and back-illuminated devices. Apart from the pixel linear dimension, it is a distinct difference that there is a metal cladding (composed of a number of metals for ohmic contact and the read-out integrated circuit hybridization) in the FPA between the heavily doped gallium arsenide used as the contact layer and the ROIC; on the contrary, the front-illuminated single pixel device consists of two heavily doped contact layers separated by the QD-absorber on a semi-infinite GaAs substrate. This paper is focused on analyzing the impact of a two dimensional metal hole array structure integrated to the back-illuminated quantum dots-in-a-well (DWELL) infrared photodetectors. The metal hole array consisting of subwavelength-circular holes penetrating gold layer (2DAu-CHA) provides the enhanced responsivity of DWELL infrared photodetector at certain wavelengths. The performance of 2D-Au-CHA is investigated by calculating the absorption of active layer in the DWELL structure using a finite integration technique. Simulation results show the enhanced electric fields (thereby increasing the absorption in the active layer) resulting from a surface plasmon, a guided mode, and Fabry-Perot resonances. Simulation method accomplished in this paper provides a generalized approach to optimize the design of any type of couplers integrated to infrared photodetectors.

  • PDF

Traveling-wave Ti:LiNbO3 optical modulator capable of complete switching (완전 스위칭이 가능한 Ti:LiNbO3 진행파 광변조기)

  • 곽재곤;김경암;김영문;정은주;피중호;박권동;김창민
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.545-554
    • /
    • 2003
  • Design of the optical modulator composed of a three-waveguide coupler and CPW traveling-wave electrodes was carried out. Switching phenomena of three-waveguide couplers were analyzed by using the coupled mode theory, and the coupling-lengths of the devices were calculated by means of the FDM. CPW traveling-wave electrodes were analysed by the CMM and SOR simulation technique in order to find the conditions of phase-velocity and impedance matching. Traveling-wave modulators were fabricated on z-cut LiNbO$_3$ substrate. Ti was in-diffused in LiNbO$_3$ to make waveguides and Au electrodes were built on the waveguides by the electrolyte technique. The fabricated modulator chip was end-polished, pig-tailed and packaged in a brass mount with K-connector. The insertion loss and the switching voltage of the optical modulator were about 4㏈ and 19V, respectively. Network analyzer was used to obtain the S parameter and the corresponding RF response. From the measurement, parameters of the traveling-wave electrodes were extracted to be Z$_{c}$= 45 Ω, N$_{eff}$=2.20, and $\alpha$$_{0}$=0.055/cm√GHZ. The measured optical response R($\omega$) was compared with the theoretically estimated one, showing both responses agree well. The measurement results revealed that 3㏈ bandwidth turned out to be about 13 GHz.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

Photo- and Sonic Degradation of Endosulfans(α, β, and sulfate) in Aqueous Solution (엔도설판류의 광 및 초음파분해)

  • Kwon, Sung Hyun;Kim, Jong Hyang;Cho, Daechul
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.460-465
    • /
    • 2007
  • Endosulfan-${\alpha}$ endosulfan-${\beta}$ and endosulfan-sulfate, which are classified as pesticides, were degraded by use of UV energy and ultrasonic irradiation. The degradation residuals were analysed by gas chromatography with an electron capture detector and TOC (total oragnic carbon) analysis. The reactions were conducted in a quartz annular reactor equipped with a low pressure mercury multilamp (8Wx2) and a sonic generator. All the aqueous solutions were concentrated as 10 mg/L initially. Endosulfans were degraded each to result in 48.2% (${\alpha}$), 50.0% (${\beta}$) and 76.5% (sulfate) of removal efficiency by UV energy, and 66.9% (${\alpha}$), 55.8% (${\beta}$) and 72.7% (sulfate) by ultrasonic irradiation, respectively. In contrast to the results of the single-component solutions, degradation of the endosulfan-sulfate was greatly suppressed to result in the lowest degradation rate and removal efficiency in the three-component solutions. This finding suggests that there should be a reversible reaction with a substantially low equilibrium constant between endosulfan-${\alpha}$ or -${\beta}$ and -sulfate in the coexistence of the three endosulfans. TOC data showed the endosulfans were decomposed by 20%~40% toward complete mineralization, producing a quantity of intermediates induced by the radical reactions. We found that all the decay reactions considered in this study nicely fell into pseudo first-order rate.

The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$ (다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구)

  • Choe, Jang-Yong;Lee, Dong-Gil;Sin, Jeong-Uk;Kim, Jae-Hyeong;Nam, Sang-Hee;Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF

A Study on the Method for the Local Transmittance Measurements of the Ocular Lens (안경 렌즈의 국소적 투과율 측정을 위한 방법에 관한 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Youk, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • Purpose: We have analyzed the transmittance distribution of the ocular lens using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The transmittance of the laser which is focused on the surface of the ocular lens was measured by using the photo-detector and lock-in amplifier and analyzed. Multi-coated, uncoated, and progressive lenses were analyzed. Results: In the measurement of the progressive lens and a physical stimulated lens, local transmittance microscopy analysis showed a high degree of match with the measurement results through the optical microscope. In addition, the average value of the transmittance is reduced and the standard deviation was increased in the presence of optical defects. In unstimulated lens, there are a large impact on transmittance whether the anti-reflective coating is presence or absence in both the local transmittance microscopy and general transmittance analysis. Conclusions: The distribution of the transmittance measured by local transmission microscopy were changed when the various stimulus is applied to the lenses. These analyzes by local transmission microscopy can be utilized as a way to evaluate or determine the uniformity of the coating film or lens.

Development of HPLC-UV method for detection and quantification of seven organic acids in animal feed (사료 중 유기산 7종 동시분석법 개발 및 유통 사료의 모니터링)

  • Kim, Jin kug;Lee, Mi Jin;Lee, Ye Ji;Kim, Hye Jin;Jeong, Min Hee;Kim, Ho Jin
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.202-208
    • /
    • 2016
  • 본 연구에서는 사료 첨가제로 이용되고 있는 유기산 7종(formic acid, malic acid, lactic acid, acetic acid, citric acid, fumaric acid, propionic acid)의 동시분석법 개발을 위한 연구를 실시하였다. 7종의 화합물은 표준물질의 Retention time과 UV spectra를 통해 구별하였고, 분석법 검증은 직선성, 민감성, 선택성, 정확성, 정밀성을 통하여 검증하였다. 그 결과로 LOD와 LOQ의 범위가 각각 43~26,755 μg/kg, 12-8,026 μg/kg으로 설정하였고, 평균 회수율이 79.3~95.2%로 우수하게 보였으며, intra-day, inter-day에 대한 전반적인 상대 표준 편차(%RSD)는 3.2% 미만으로 나타났다. 이와 같이 검증된 자료를 통해 유기산의 동시분석에 대한 직선성, 민감성, 선택성, 정확성 및 정밀성을 확인하였고, 높은 수준을 나타냄을 알 수 있었다. 이를 바탕으로 유기산이 검출되는 단미사료 46 가지를 분석에 적용하여 진행하였고, 정량과 동시분석 검출을 위한 방법은 RP-HPLC/UV 검출기를 이용하여 성공적으로 개발되었다. 따라서 본 연구결과를 바탕으로 하여 사료 중의 유기산의 분석이 신속하고 정확해졌을 뿐 아니라, 다른 종류의 사료 또한 이를 적용하여 효율적으로 이용할 수 있을 것으로 판단된다.