• Title/Summary/Keyword: photo-detector

Search Result 196, Processing Time 0.031 seconds

A possible optical measuring technique for corona discharge by use of Pockets sensor (광계측 시스템을 이용한 코로나 방전 검출)

  • Kang, Won-Jong;Ma, Ji-Hoon;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1561-1563
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. And also it is constructed by He-Ne laser, optical fiber, $LiNbO_3$ Pockels cell, photo detector, grin lens, oscilloscope and PC. The characteristics of the developed prototype sensor are investigated under AC and corona discharges.

  • PDF

A Development of Diaphragm Sensor for Detecting Partial Discharge (부분방전 측정을 위한 Diaphragm 센서 개발)

  • Kang, W.J.;Park, Y.I.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1528-1530
    • /
    • 1998
  • In this work, a possible new PD detection technique, based on the Michelson Interferometer, has been proposed. Laser beam transmitted by optical fiber is spliced into two-laser beam by 50/50 coupler, one is reflected on diaphragm, which is vibrated by ultrasonic sound, and then modulated. The other one is reference beam. They are collected into 50/50 coupler making interferenced beam which could be detected by photo detector.

  • PDF

STUDY ON THE ELECTRON GENERATION BY A MICRO-CHANNEL PLATE BASED ON EGS4 CALCULATIONS AND THE UNIVERSAL YIELD CURVE

  • Moon, B.S.;Han, S.H.;Kim, Y.K.;Chung, C.E.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.177-181
    • /
    • 2001
  • The conversion efficiency of a cesium iodine coated micro-channel plate is studied. We use the EGS4 code to transport photons and generated electrons until their energies become less than 1keV and 10keV respectively. Among the generated electrons, the emission from the secondary electrons located within the escape depth of 56nm from the photo-converter boundary is estimated by integrating the product of the secondary electrons with a probability depending only on their geometric locations. The secondary electron emission from the generated electrons of energy higher than 100eV is estimated by the 'universal yield curve'. The sum of these provides an estimate for the secondary electron yield and we show that results of applying this algorithm agree with known experimental results. Using this algorithm, we computed secondary electron emissions from a micro-channel plate used in a gas electron multiplier detector that is currently being developed at Korea Atomic Energy Research Institute.

  • PDF

Spray Measurement Using Optical Line Patternator at High Ambient Pressure (광학 선형 패터네이터를 이용한 고압 환경 하에서의 분무 측정)

  • Koh Hyeonseok;Shin Sanghee;Yoon Youngbin
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 2005
  • Optical Line Patternator(OLP) has been applied to get a distribution of the spray at high ambient pressure. OLP is a combined technique of extinction measurement and image processing. The attenuated intensity of laser beam after traversing spray region was measured by using a photo-detector, and the line image of Mie-scattering was captured simultaneously in the path of each laser beam by using a CCD camera. The distribution of extinction coefficient in the spray is obtained by processing these data with the algebraic reconstruction technique. From the distribution of extinction coefficient, the surface distribution of spray can be reconstructed. OLP does not use laser sheet but use laser beam so that the noise effect of multiple scattering, caused by increasing number density of droplet in high pressure environment, is reduced drastically. OLP is expected as a suitable method which can investigate the characteristics of relatively large spray under the high pressure environment such as liquid rocket engine.

  • PDF

Visible Light Identification System Using Optoelectronic Feedback of A Lighting LED (조명용 LED의 광전궤환을 이용한 가시광 무선인식장치)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.193-198
    • /
    • 2011
  • In this paper, we used optoelectronic feedback to generate the carrier frequency for the ASK modulation of a lighting LED. A solar cell was used for photo-detector in the feedback circuit, and the LED light was ASK modulated by controlling the ON/OFF state of the switch that is installed in the feedback loop. The oscillation frequency of the optoelectronic feedback loop was about 50 kHz and the data rate of the ASK modulation was 9.6 kbps. In experiments, the optoelectronic feedback circuit was used for the ASK modulation of a lighting LED in the transponder of a visible light identification system, and data exchange between the transponder and the reader was successfully carried out.

Optical Fiber Atmospheric Ozone Monitor (광섬유 대기오존 모니터)

  • 정완영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.201-204
    • /
    • 2002
  • A high accuracy ozone monitor using UV absorption method was developed for ambient ozone monitoring. The system was mainly composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit. The optical signal from the CCD array that provides unusually high response and excellent optical resolution for ozone concentration was converted to digital signal and the digital signal was displayed on screen using PC interface. The optical signal was propagated using optic fiber to reduce optical loss to increase the accuracy of the measuring system. This paper has been studied a interworking signalling protocol between two hybrid networks by analyzing Satellite B-ISDN architecture, DSS2 Layer 3 Signalling protocol, B-ISUP protocol, S-BISUP protocol stack and so on. Also in the paper, messages and primitives have been defined for B-ISDN's Connection Type, Ownership and each protocol in order to connect point-to-multipoint. The ozone sensing properties of the CCD ozone monitor was compared with those of the photo multiplier ozone monitor.

  • PDF

A development of map building sensor system for mobile robot using low cost photo sensor

  • Hyun, Woong-Keun
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.281-285
    • /
    • 2009
  • Mobile robot has various sensors for describing the external world. The ultrasonic sensor widely applied to the most mobile robot to detect the obstacle and environment owing to low cost, its easy to use. However, ultrasonic sensor has major problems: the uncertainty information of sensor, false readings caused by specular reflection, multi path effect, low angular resolution and sensitivity to changes in temperature and humidity. This paper describes a sensor system for map building of mobile robot. It was made of low cost PSD (Position Sensitive Detector) sensor array and high speed RISC MPU. PSD sensor is cost effective and light weighting but its output signal has many noises. We propose heuristic S/W filter to effectively remove these noises. The developed map building sensor system was equipped on a mobile robot and was compared with ultrasonic sensor through field test.

Diffused Aeration System(DAS)을 이용한 지하수내 TCE 제거 효율 평가: 주입 공기량에 따른 제거효율 비교

  • Kim Jin-Hun;Park Seong-Min;Seok Hui-Jun;Kim Hyeong-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.338-341
    • /
    • 2006
  • 본 연구에서는 지하수내 TCE 농도가 높은 2개 지역을 선정하여 3회에 걸쳐 공기탈기법 시험을 실시하였다. 2개 지역의 지하수내 TCE 배경 농도는 각각 0.360, 0.317 mg/L이며 반응조에 주입된 공기는 각각 17.14, 44.78, 76.51 L/min의 비율로 주입하였다. 또한 반응조에서 배출되는 기체내의 TCE의 농도를 측정하기위해 PID(photo-ionization detector)를 장착하여 측정하였다. PID를 이용하여 배출되는 기체를 측정한 결과, TCE 농도는 $6{\sim}8$분만에 최고 농도로 배출되었고 시간이 지날수록 천천히 감소하는 형태를 나타내었다. 반응조내의 TCE 농도 변화는 공기 유입 속도에 따라 매우 큰 변화를 나타내었다. TCE가 17.14 L/min의 공기유입속도에서 160분 동안 64%, 44.78 L/min에서 135분 동안 93%, 76.51 L/min에서 120분 동안 95.3%가 제거되었다. 따라서 TCE를 제거하기 위한 DAS 기법은 공기의 주입비율에 따라 제거 속도의 큰 변화를 보였다.

  • PDF

Vision chip for edge detection with a function of pixel FPN reduction (픽셀의 고정 패턴 잡음을 감소시킨 윤곽 검출용 시각칩)

  • Suh, Sung-Ho;Kim, Jung-Hwan;Kong, Jae-Sung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.191-197
    • /
    • 2005
  • When fabricating a vision chip, we should consider the noise problem, such as the fixed pattern noise(FPN) due to the process variation. In this paper, we propose an edge-detection circuit based on biological retina using the offset-free column readout circuit to reduce the FPN occurring in the photo-detector. The offset-free column readout circuit consists of one source follower, one capacitor and five transmission gates. As a result, it is simpler and smaller than a general correlated double sampling(CDS) circuit. A vision chip for edge detection has been designed and fabricated using $0.35\;{\mu}m$ 2-poly 4-metal CMOS technology, and its output characteristics have been investigated.

A possible application of the nonuniform electric field measurement using Pockets effect (포켈스 효과를 이용한 불평등 전계 측정)

  • Kang, W.J.;Lim, Y.S.;Choi, J.O.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF