• 제목/요약/키워드: photo sensor

검색결과 344건 처리시간 0.026초

황화납 양자점 기반 단파장 적외선 수광소자의 전기적 특성 향상을 위한 산화아연 나노입자 농도의 중요성 (Importance of Zinc Oxide Nanoparticle Concentration on the Electrical Properties of Lead Sulfide Quantum Dots-Based Shortwave Infrared Photodetectors)

  • 서경호;배진혁
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.125-130
    • /
    • 2022
  • We describe the importance of zinc oxide nanoparticle (ZnO NP) concentration in the enhancement of electrical properties in a lead sulfide quantum dot (PbS QD)-based shortwave infrared (SWIR) photodetector. ZnO NPs were synthesized using the sol-gel method. The concentration of the ZnO NPs was controlled as 20, 30 and 40 mg/mL in this study. Note that the ZnO NPs layer is commonly used as an electron transport layer in PbS QDs SWIR photodetectors. The photo-to-dark ratio, which is an important parameter of a photodetector, was intensively examined to evaluate the electrical performance. The 20 mg/mL condition of ZnO NPs exhibited the highest photo-to-dark ratio value of 5 at -1 V, compared with 1.8 and 0.4 for 30 mg/mL and 40 mg/mL, respectively. This resulted because the electron mobility decreased when the concentration of ZnO NPs was higher than the optimized value. Based on our results, the concentration of ZnO NPs was observed to play an important role in the electrical performance of the PbS QDs SWIR photodetector.

Development of SPR Gas Sensor for Small Molecules Using Molecularly Imprinted Polymer Thin Films

  • 장성우;진성일;박찬량
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.242.2-242.2
    • /
    • 2011
  • Molecularly imprinted polymer thin films were applied to develop a gas sensor based on the surface plasmon resonance phenomenon for small gaseous molecules such as toluene and xylene. The imprinted polymer films were synthesized via photo-polymerization method using various combination of templates, functional monomers and cross-linkers. The temperature of pre-polymerization solutions and the power of UV light were controlled for optimized performance of gas sensing. The morphology and porosity of the polymer films were controlled by varying the mixing ratios of the pre-polymerization solutions and confirmed by atomic force microscopy. By fitting the adsorption/desorption sensorgrams to conventional kinetic models, the effects of different templates and cross-linkers were interpreted in term of the structural differences of the polymer networks formed on the gold film. The sensitivity and selectivity of sensors were estimated for toluene and xylene, and also for humidity and other gaseous molecules such as formaldehyde and ammonia.

  • PDF

광계측 시스템을 이용한 코로나 방전 검출 (A possible optical measuring technique for corona discharge by use of Pockets sensor)

  • 강원종;마지훈;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1561-1563
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. And also it is constructed by He-Ne laser, optical fiber, $LiNbO_3$ Pockels cell, photo detector, grin lens, oscilloscope and PC. The characteristics of the developed prototype sensor are investigated under AC and corona discharges.

  • PDF

Micro pH Sensor Using Patterned Hydrogel with pH Indicators

  • Jang, Ji-Sung;Kwon, Sung-Hoon
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.234-237
    • /
    • 2011
  • This paper presents a study into pH Indicator-Embedded hydrogel micro-particles which are encoded various shapes according to the captured indicator. We incorporate various pH indicators into a photo-curable hydrogel, PEG-DA(Poly(ethylene glycol) diacrylate). Using the latest fluidic lithography techniques, we can easily fabricate variously patterned hydrogel particles based on in-situ photopolymerization of the PEG-DA in a micro-fluidic channel. The shape of the particle is related to the pH indicator inside the particle. We demonstrate that the micro pH sensors change their colors according to the pH levels. The micro pH sensors have various characteristics that are related to the curing time, particle size, etc. By changing these conditions, we can adjust the long term stability and reaction time of the hybrid micro pH sensors.

선체 블록의 판접 위치 획득을 위한 센서 모듈 시제품 개발 (A Prototype of Sensor Module to Control the Position of Hull Block for Tack Welding)

  • 전정익;이장현;손금준
    • 대한조선학회논문집
    • /
    • 제49권1호
    • /
    • pp.87-92
    • /
    • 2012
  • Alignment of the main plates during the tack welding is essential to block assembly since most of the curved blocks and outfitting parts are assembled on the jigs and fixtures. Tact welding of main plates is the initial process of the curved hull block assembly. Due to the heavy weight of the main plates it is difficult to locate the plate on the accurate position of the jig and fixtures before welding. The conventional masonry process requires much time and manual work in order to achieve the accurate alignment. This labour-intensive process results in relatively high errors and correction works. Due to their larger dimensions and heavier weights, these hull blocks are not ergonomically desirable and, therefore, various mechanical devices such as hydraulic balancers or hydraulic jigs are used for the plate alignment. In this study, the position-sensing scheme implemented by sensors is presented in order to align the main plates on the accurate position during the hull block assembly. Integrating the Infrared photo sensors and micro processor unit, a small scaled prototype of the position-sensing module is developed to determine the alignment of main plates.

백금전극과 감광성 고분자를 이용한 ISFET 포도당 및 자당센서의 감지성능 개선 (The Improvement of Sensing Performance of ISFET Glucose and Sucrose Sensors by Using Platinum Electrode and Photo-crosslinkable Polymers)

  • 조병욱;장원덕;김창수;박이순;손병기
    • 센서학회지
    • /
    • 제4권4호
    • /
    • pp.23-28
    • /
    • 1995
  • 백금작업전극과 광가교화된 효소고정화막을 가진 ISFET 포도당 및 자당센서가 제조되었다. 효소반응의 부산물인 과산화수소수($H_{2}O_{2}$)는 백금전극표면에서 분해되어 센서의 감지특성을 개선시키고, 광가교화 고분자(PVA-SbQ)가 효소고정화막으로 이용되어 센서의 응답시간을 단축하였다. 그리고 백금전극의 면적변화에 따라 센서의 응답크기는 증가하였다. 센서의 응답시간은 $3{\sim}5$분이었으며, $30{\sim}300mg/dl$의 포도당 및 자당농도에서 센서의 선형적인 응답을 보였다.

  • PDF

Eu 도핑 SrAl2O4 형광체의 광 여기 전류 특성에 대한 Dy 코-도핑 효과 (Dy co-doping effect on photo-induced current properties of Eu-doped SrAl2O4 phosphor)

  • 김세기
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.48-53
    • /
    • 2009
  • $Eu^{2+}$-doped ${SrAl_2}{O_4}$ and $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors have been synthesized by conventional solid state method. Photocurrent properties of $Eu^{2+}$ doped ${SrAl_2}{O_4}$ and $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors, in order to elucidate $Dy^{3+}$ co-doping effect, during and after ceasing ultraviolet-ray (UV) irradiation have been investigated. The photocurrent of $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors during UV irradiation was 4-times lower than that of $Eu^{2+}$-doped ${SrAl_2}{O_4}$ during UV irradiation, and 7-times higher than that of $Eu^{2+}$-doped ${SrAl_2}{O_4}$ after ceasing UV irradiation. The photocurrent results indicated that holes of charge carriers captured in hole trapping center during the UV irradiation and liberated after-glow process, and made clear that $Dy^{3+}$ of co-dopant acted as a hole trap. The photocurrent of ${SrAl_2}{O_4}$ showed a good proportional relationship to UV intensity in the range of $1{\sim}5mW/cm^2$, and $Eu^{2+}$-doped ${SrAl_2}{O_4}$ was confirmed to be a possible UV sensor.

등가회로 모델에 의한 레이저다이오드의 누설전류 해석 (Analysis of Leakage Current of a Laser Diode by Equivalent Circuit Model)

  • 최영규;김기래
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.330-336
    • /
    • 2007
  • 본 논문에서는 디지털 의료 영상 및 진단 분야 그리고 산업용으로도 활용 가능한 싱글 포톤 계수형 영상센서를 $0.18{\mu}m$ triple-well CMOS(Complementary Metal Oxide Semiconductor) 공정을 사용하여 설계하였다. 설계된 Readout 칩용 싱글 픽셀은 디지털 X-ray 이미지 센서모듈을 간단화 하기 위해 단일 전원전압을 사용하였으며, Preamplifier의 출력 전압인 signal voltage(${\Delta}Vs$)를 크게 하기 위해 Folded Cascode CMOS OP amp를 이용한 Preamplifier를 설계하였으며, 기존의 Readout 칩 외부에서 인가하던 threshold voltage를 Readout 칩 내부에서 생성해 줄 수 있도록 Externally Tunable Threshold Voltage Generator 회로를 새롭게 제안하였다. 그리고, Photo Diode에서 발생하는 Dark Current Noise를 제거하기 위한 Dark Current Compensation 회로를 제안하였으며, 고속 counting이 가능하고, layout 면적이 작은 15bit LFSR(Linear Feedback Shift Resister) Counter를 설계하였다.

광용적맥파의 신호 패턴을 이용한 호흡 검출 기법 (Respiration Detection Method Using the PPG Signal Pattern)

  • 박문수;김정구
    • 한국멀티미디어학회논문지
    • /
    • 제19권11호
    • /
    • pp.1862-1870
    • /
    • 2016
  • A respiration is one of the most useful techniques for vital checking and an abnormal respiration is often the earliest sign of critical illness. Detection of respiration is based on the photo-plethysmography (PPG) with photodiode technique. Because PPG sensor using photodiode can be easily miniaturized, it is suitable for wearable devices. A system to measure respiration rate based on PPG signal is implemented and for a reliable measurement an improved algorithm in accuracy using PPG signal pattern is proposed in this paper. As results regarding to three types of respirations (regular interval, free interval, and weak respiration) the proposed algorithm showed error rate of 0.047, 0.067, and 0.122 respectively.

실시간 공연비 제어를 위한 화염 자발광 측정 실험 (An Experiment of Flame Chemiluminescence Measurement for Real Time Air/Fuel Ratio Control)

  • 이진기;권민준;이창엽;김세원;신명철
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.29-30
    • /
    • 2012
  • The objectives of this study are to examine the variation of flame chemiluminescence on flame condition and to evaluate the possibility to apply the optical sensor for air/fuel ratio control. Flame chemiluminescence is one of the most important factor to judge the real time flame condition like a air/fuel ratio. In this paper, it is experimentally found that a strong relationship between the air/fuel ratio and optical element output (i.e., photo diode) should be existed. This is verified through the flame spectral analysis for various PD output signal.

  • PDF