• 제목/요약/키워드: phase speed

검색결과 2,635건 처리시간 0.03초

보행 속도 변화에 따른 발목 관절의 운동학적 분석과 하퇴 근육의 근전도 분석 (The kinematic analysis of the ankle joint and EMG analysis of the lower limbs muscle for the different walking speed)

  • 문곤성
    • 한국운동역학회지
    • /
    • 제15권1호
    • /
    • pp.177-195
    • /
    • 2005
  • The purpose of this study was to analyze the kinematic variables of ankle joints and EMG signal of the lower limbs muscle activity for the different walking speed. The subjects were 6 males of twenties. It was classified into three different walking speed-0.75m/s, 1.25m/s, 1.75m/s. The walking performances were filmed by high speed video camera and EMG signal was gained by ME3000P8 Measurement Unit. Tibialis anterior(TA), Gastrocnemius medial head(GM), Gastrocnemius lateral head(GL), Ssoleus(SO) were selected for the dorsiflexion and plantarflexion of the ankle joint. The result of this study were as follows: 1. In the gait cycle, The time parameters for the phases were showed significant difference without the terminal stance phase and terminal swing phase for the different walking speed. 2. The angle of ankle joint was no significant difference for each time point and MDF, MPF but increasing walking speed the angle had the increasing pattern slightly. 3. The angular velocity of ankle joint was showed the significant difference for LHC, RTO, RKC, LHU, MPF and MDF point along the walking speed. 4. TA was showed about 2-3 times muscle activity at the 1.75m/s than 1.25m/s in some phases. And it was showed the similar muscle activity between the 0.75m/s and 1.25m/s but, showed a little much muscle activity in the 0.75m/s. GM was showed about 2-3 times muscle activity in the 1.75m/s than 1.25m/s, and even much muscle activity at the 0.75m/s than 1.25m/s in some phases. GL was showed increasing pattern of muscle activity specially in the initial swing phase as the walking speed increased. SO was showed about 3 times muscle activity in the 1.75m/s than 1.25m/s during the plantarflexion of ankle joint. It was showed the similar muscle activity between the 0.75m/s and 1.25m/s but, showed a little much muscle activity in the 1.25m/s.

투구 속도 증가에 따른 타자의 발 움직임과 지면 반력의 변화 (The Movement of Foot and the Shift of Ground Reaction Force in Batters according to the Ball Speed Increase)

  • 이영석;은선덕
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.191-202
    • /
    • 2004
  • The batting performance in baseball is a repetitive movement. In order to make the stabilization of posture and the efficient shift of body weight, both the range of stance and stride are important. The previous studies explained that the consistent stride which included the amount of time, stance, and direction were needed. However, the batting performance is frequently changed according to the several speed of ball. Therefore, this study was to analyze the reaction time, the range of stance, the change of stride, and the change of GRF during the batting movement in three kinds of ball speed (120km/h, 130km/h, & 140km/h). Seven elite players are participated in this study. 1. The reaction time of the stride phase was short whereas the time of the swing phase was long according to the increasing ball speed. 2. The range of the stance was wide and the mediolateral direction of the stride was decreased according to the increasing ball speed. 3. In the three kinds of ball speed, the change of body weight was transferred to the center, the rear foot, and the front foot directions. The ball speed of 130km/h showed the high frequency of the suitable batting. At this ball speed, the movement of the body weight was shifted smoothly and the value of the Ground Reaction Force was large enough.

달리기 시 속도 증감에 따른 지지국면에서 발 분절 움직임 분석 (Effects of Running Speed on the Foot Segments Motion at the Stance Phase)

  • 류지선
    • 한국운동역학회지
    • /
    • 제22권1호
    • /
    • pp.35-42
    • /
    • 2012
  • The aim of the present study was to investigate effect of running speed conditions on the kinematic pattern of the metatarsus, mid-foot, calcaneus. Twenty-two healthy young adults were made to run on treadmill at three different running speeds(normal speed, 9.2; slow speed, 7.4; fast speed, 11.1km/hr.) and the trajectories of the 10 reflective markers for each subject were recorded by an eight-camera motion capture system at 200 Hz. Three-dimensional angles for the foot segment in the support phase during running were calculated according to Euler's technique. Results showed that running speed did not affect the peak of the dorsi/plantar flexion, inversion/eversion, and adduction/abduction or their range of motion for each foot segment. However, when the running speed was fast, significant differences were found in the peak of the plantar flexion, eversion, and adduction and ROM(range of motion) of the dorsi/plantar flexion, inversion/eversion, and adduction/abduction between the foot segments, metatarsus, mid-foot, and calcaneus. It was proposed that the foot segment should be analyzed from a multi-segment system point of view on the basis of anatomical reference during locomotion.

Local Flow Speed Measurement Using Tunable AC Thermal Anemometry

  • Chung Won Seok;Kwon Ohmyoung;Lee Joon Sik;Choi Young Ki;Park Seungho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1449-1459
    • /
    • 2005
  • This paper shows the results of local flow speed measurement using tunable AC thermal anemometry, which is suitable for the accurate measurement of wide range flow speed. The measurement accuracy is verified through the comparison between the measurement data and the analytic solution of the sensor temperature oscillation in stationary fluid. The relation between the phase lag and the flow speed is experimentally investigated at various conditions. The measurement sensitivity for low flow speed improves in a low frequency region and that for high flow speed improves in a high frequency region. Also, the sensitivity increases with decreasing thermal conductivity of the surrounding fluid. The local flow speed could be measured as low as 1.5 mm/s and the highest measurement resolution was 0.05 mm/s in the range of 4.5 $\~$5.0 mm/s at 1 Hz in this experiment.

5상 유도전동기의 속도응답특성 개선을 위한 직접토크제어 시스템 (A Direct Torque Control System for Improving Speed Response of Five-Phase Induction Motor)

  • 김민회;최성운
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.66-74
    • /
    • 2012
  • This paper propose a improved direct torque control(DTC) system for improving operation of five-phase squirrel-cage induction motor(IM). A five-phase IM drives present unique characteristics due to the additional degrees of freedom and also drives possess many others advantage compared with the traditional three-phase motor drive system, such as reducing a amplitude of torque pulsation and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated windings and the produced back-electromotive force(EMF) is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus third harmonic of currents, there is necessary to controlled 3rd harmonic current. Also a DTC method is advantageous when it is applied to the five-phase IM, because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors into the three-phase inverter drive system. For presenting the superior performance of the proposed DTC, experimental results of speed control are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[hp] IM.

Study on Design of Air-water Two-phase Flow Centrifugal Pump Based on Similarity Law

  • Matsushita, Naoki;Furukawa, Akinori;Watanabe, Satoshi;Okuma, Kusuo
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권2호
    • /
    • pp.127-135
    • /
    • 2009
  • A conventional centrifugal pump causes a drastic deterioration of air-water two-phase flow performances even at an air-water two-phase flow condition of inlet void fraction less than 10% in the range of relatively low water flow rate. Then we have developed a two-phase flow centrifugal pump which consists of a tandem arrangement of double rotating cascades and blades of outer cascade have higher outlet angle more than $90^{\circ}$. In design of the two-phase flow pump for various sized and operating conditions, similarity relations of geometric dimensions to hydraulic performances is very useful. The similarity relations of rotational speed, impeller diameter and blade height are investigated for the developed impeller in the present paper. As the results, the similarity law of rotational speed and impeller diameter is clarified experimentally even in two-phase flow condition. In addition, influences of blade height on air-water two-phase flow performances indicate a little difference from the similarity relations.

Performance Evaluation of the Field-Oriented Control of Star-Connected 3-Phase Induction Motor Drives under Stator Winding Open-Circuit Faults

  • Jannati, Mohammad;Idris, Nik Rumzi Nik;Aziz, Mohd Junaidi Abdul
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.982-993
    • /
    • 2016
  • A method for the fault-tolerant vector control of star-connected 3-phase Induction Motor (IM) drive systems based on Field-Oriented Control (FOC) is proposed in this paper. This method enables the control of a 3-phase IM in the presence of an open-phase failure in one of its phases without the need for control structure changes to the conventional FOC algorithm. The proposed drive system significantly reduces the speed and torque pulsations caused by an open-phase fault in the stator windings. The performance of the proposed method was verified using MATLAB (M-File) simulation as well experimental tests on a 1.5kW 3-phase IM drive system. This paper experimentally compares the operation of the proposed fault-tolerant vector controller and a conventional vector controller during open-phase fault.

가변속 구동을 위한 단상 유도전동기의 벡터제어 (Vector Control of Single Phase Induction Motor for Variable Speed Drive)

  • 이득기;이경주;정종진;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1260-1263
    • /
    • 2000
  • Vector control of a single phase induction machine(SPIM) is usually employed by mechanical methods than electrical ones. The disadvantage of a SPIM has large noise at the starting. Using auxiliary winding which is only utilized for starting, the SPIM can be controlled with the vector control method. Regarding a auxiliary winding one phase, the SPIM is analyzed by the unsymmetrical two phase motor and phase transformation is unnecessary such as three phase IM. Including a auxiliary winding, SPIM is modeled by mathematical getting by component of turns ratio with main to auxiliary winding. It will be take with complicated resultant formula, by comparison to symmetrical three phase TM. For using the vector control theory, it must be decoupled of rotor flux and torque component. stator current is controlled and decoupled. This paper presents a variable-speed control system of SPIM, which to decoupled with flux and torque component and to use machine equivalent circuit referred to rotor, conventionally three phase IM by similar method.

  • PDF

여자상의 초기 전류증가율 측정에 의한 Switched Reluctance Motor의 Sensorless 알고리즘 (New Sensorless Algorithm for SRM Based on Initial di/dt Measurement of Excited Phase Current)

  • 임준영;;신두진;오재윤;김정철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.302-304
    • /
    • 1996
  • In this paper, a new algorithm for sensorless speed control of switched reluctance motor (SRM) is proposed. It is based on the measurement of initial rate of change of phase current. The initial rate of rise of phase current mainly depends up on the phase inductance at the time instant when the phase is excited. Therefore, the measurement of initial di/dt permits rotor position estimation, which is used to trigger the next phase. In the proposed technique, there is no need to generate additional current pulses when a phase is not excited. Therefore, this scheme does not introduce the unwanted braking torque. Also, only one current measurement is made every time a phase is excited. This reduces the computational load on the micro-controller and enhances the speed range of the sensorless drive. By using this scheme it is possible to implement the sensorless control of SRM using low cost micro-controller.

  • PDF

5-GHz Delay-Locked Loop Using Relative Comparison Quadrature Phase Detector

  • Wang, Sung-Ho;Kim, Jung-Tae;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제2권2호
    • /
    • pp.102-105
    • /
    • 2004
  • A Quadrature phase detector for high-speed delay-locked loop is introduced. The proposed Quadrature phase detector is composed of two nor gates and it determines if the phase difference of two input clocks is 90 degrees or not. The delay locked loop circuit including the Quadrature phase detector is fabricated in a 0.18 um Standard CMOS process and it operates at 5 GHz frequency. The phase error of the delay-locked loop is maximum 2 degrees and the circuits are robust with voltage, temperature variations.