• Title/Summary/Keyword: phase shift control

Search Result 276, Processing Time 0.024 seconds

Interval-based Controller Design Considering Parameter Variations for DC/DC Converters (DC/DC 컨버터의 파라미터 변화를 고려한 구간분석법 기반 제어기 설계)

  • Choi, Sungjin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.879-885
    • /
    • 2013
  • By performing interval analysis on the system transfer function, we propose an improved method of control loop design for a DC/DC converter. In conventional design methods, the effect of system parameter change due to the specified range of operating conditions and production tolerances in power components should be checked a posteriori, because this may result in a transfer function shift and performance degradation. In the proposed method, a possible parameter change is considered a priori in the design step in order that the desired crossover frequency and sufficient phase margin can be achieved even in the worst case condition. As an illustrative example, a buck dc/dc converter is designed by two different methods and performance comparisons are performed to verify the feasibility of the proposed scheme.

Constant Power Control of Variable Input Robust Resonant FB DC-DC Converter (순시 가변입력에 강인한 공진형 FB DC-DC Converter의 정출력 제어)

  • Hwang, Y.M.;Park, S.W.;Choi, S.F.;Shin, D.R.;Chung, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1351-1353
    • /
    • 2000
  • In this paper, it is proposed to constant power control of solar power system. The solar power system has disadvantage that low power density and variable power output. Proposed strategy is controled by DC/DC converter using phase shift PWM and I-PD type control applying type 1 digital system. The validity of proposed control strategy is verified from simulations results using PSIM.

  • PDF

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

Design and Implementation of a Bidirectional Power Supply Charger Using Super Capacitors and Solar Panel for Robot Cleaner Applications (슈퍼 커패시터 및 태양전지를 이용한 로봇청소기용 양방향 충전시스템 설계)

  • Zheng, Tao;Piao, Sheng-Xu;Kwon, Dae-Hwan;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.97-102
    • /
    • 2016
  • In this paper, a bidirectional power supply charger is proposed. This system used a solar cell panel to generate electricity and used super capacitors to store these energies, which can be used for the robot cleaner or some other electronic products. This system include a phase-shift controlled bidirectional dual active bridge (DAB) converter, solar panel super capacitors and DSP controller. In the daytime it can charge to the super capacitors to store the energy generated by the solar cell panel and in the night it will release the energy stored in the super capacitors to loads. A prototype of the proposed bidirectional power supply charger system was designed which can achieve 18V to 30V input, 10V/20W output to super capacitors and 9V/6.5W output when it acts as a charger for the robot cleaner. The system is verified to be sTable and reliable by both the simulation and experimental results.

A Characteristic Analysis of Instantaneous Voltage Resultant Control-Based Double Full-Bridge High Frequency Inverter (순시전압 합성제어형 2중 풀 브릿지 고주파 인버터 특성 해석)

  • Jung, Won-Young;Kim, Sung-Chul;Min, Byung-Jae;Nam, Seung-Sig;Ro, Chae-Cyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.492-494
    • /
    • 1996
  • This paper describes a study on the series resonant inverter using the double full-bridge, and the output voltage of the proposed inverter is controlled by phase shift angle of the outputs of two inverters. These control schemes can be reduce the switching loss and EMI, etc, which the inverter is drived by auto following control of output frequency, because it is impossible for switching devices to be always turned on and off at zero voltage or zero current. Theoretical characteristics of the proposed double inverter circuit are compared with Pspice simulation and experimental results.

  • PDF

A Study on Development of 1.5 [kW] Low-cost Battery Charger for NEVs(Neighborhood Electric Vehicles) (NEV용 1.5[kW]급 저가형 충전기 개발에 관한 연구)

  • Lee, Chan-Song;Jeong, Jin-Beom;Lee, Baek-Haeng;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.574-579
    • /
    • 2012
  • In this paper, the battery charger developed which is satisfy by the characteristics of the rapid control and reduce the cost of the charger. analog-digital mixed mode controller developed with dedicated IC for PWM control and low-performance micro-processor is using for the operation control of charger. The low-cost NEV charger developed to verify the performance and usability is verified with charging battery experiment by of using developed charger.

Output Power Control by Phase Shift of Driving Signal of switching device in High Frequency inverter Circuit (고주파 인버터회로에서 스위칭소자의 구동신호 위상천이에 의한 출력제어)

  • Lee Bong-Seob;Choi Shin-Hyeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.217-220
    • /
    • 2005
  • 본 논문에서는 고주파 전류형 인버터를 제안하고 인버터의 출력방법에 대해 논하고 있다. 인버터의 출력제어 방법은 스위칭 소자에 인가되는 구동신호의 위상천이를 부여하여 위상천이에 따라 출력을 제어하고 있으며, 제한회로의 동작원리와 특성평가는 정규화 파라메타를 도입하여 기술하였다. 또한 회로설계에 필요한 출력특성은 수치해석에 의해 평가 자료를 도출하고 실험 장치를 제작하여 이론결과와 비교 검토하여 특성평가의 정당성을 입증하였다.

  • PDF

Voltage-fed high frequency resonent inverter of instantaneous current phaser control method (순시 전류 phaser 제어방식의 전압형 고주파 공진 인버터)

  • LEE K.H.;RO C.K.;KIM D.H.;LEE B.S.;PARK J.K.;JUNG B.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.348-351
    • /
    • 2001
  • In this paper, voltage-fed high frequency resonant inverter of instantaneous current phaser control method used to DC voltage source separated is proposed. In the output control method, a novel circuit type of phase shift driving signal method with CVCF illustrated, also the operation principle of the proposed circuit is described in detail and its characteristics are presented as to normalized parameters. According to the each mode, in order to the circuit analysis and characteristic evaluation of the state equation are derives and present used to normalized parameter. In the future, this proposed inverter show that it can be practically used as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF

Phase Shift Controlled Clamp Mode Forward Multi-Resonant Converter (위상 변위 제어 클램프 모드 포워드 다중공진형 컨버터)

  • Kim, Hee-Il;Kim, Chang-Sun;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.191-194
    • /
    • 1995
  • 소프트 스위칭 능동 클램프 회로와 위상 변위 제어회로를 이용하여 위상 변위 제어 클램프 모드 포워드 다중진공형 컨버터를 제안하였다. 제안된 컨버터는 일정한 스위칭 주파수에서 동작하므로 설계가 용이하고 주 스위치의 전압 스트레스를 입력 전압의 2-3배로 줄일 수 있다. 컴퓨터 시뮬레이션을 통해 제안된 회로의 이론적인 동작 파형을 확인하였으며 타당성을 입증하기 위하여 1MHz, 5V, 50W 위상 변위 제어 클램프 모드 포워드 다중공진형 컨버터를 제작하여 실험한 결과 주스위치의 최대 전압 스트레스는 입력전압의 3배로 저감하였고, 부하 전류가 증가함에 따라 주스위치에 걸리는 전압 스트레스와 전류 스트레스가 감소하며, 최고 84.2%의 효율을 얻었다.

  • PDF

Post-disturbance Recovery Pattern in the Soft Corals-Macroalgae Mixed Habitat in Jeju Island, Korea

  • Kim, Junsu;Hong, Seokwoo;Yang, Kwon Mo;Macias, Daniela;Kim, Jeong Ha
    • Journal of Marine Life Science
    • /
    • v.6 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • Post-disturbance recovery pattern of subtidal soft corals-macroalgae mixed community and the role of water depth were investigated. The experiment was conducted in a subtidal rock wall of Munseom, Jeju Island, Korea for 2.5 years. Artificial disturbance was done at established treatment plots at depths of 10, 15 and 20 m and were then compared with undisturbed control plots. After disturbance, recovery of soft corals was very slow, whereas macroalgae quickly occupied the plots and reached a similar level as the control in 6 months, and this pattern was consistent at all water depths. This unbalanced speed of recovery caused higher macroalgae establishment than soft corals in treatment compared to control plots, indicating a possible phase shift in the community structure. This study provides an important implication for the necessity of monitoring the influence of disturbance at a larger scale, from a conservation perspective of soft corals in Jeju coast.