• 제목/요약/키워드: phase response

검색결과 2,086건 처리시간 0.025초

이차 선형 시불변 비최소 위상 시스템의 설정값 조정을 위한 새로운 슬라이딩 모드 제어 (A New Sliding Mode Control for Set-point Regulation of Second Order LTI Nonminimum Phase Systems)

  • 이하준;박철훈
    • 제어로봇시스템학회논문지
    • /
    • 제13권10호
    • /
    • pp.990-999
    • /
    • 2007
  • We deal with second order NMP(Non-Minimum Phase) systems which are difficult to control with conventional methods because of their inherent characteristics of undershoot. In such systems, reducing the undesirable undershoot phenomenon makes the response time of the systems much longer. Moreover, it is impossible to control the magnitude of undershoot in a direct way and to predict the response time. In this paper, we propose a novel two sliding mode control scheme which is capable of determining the magnitude of undershoot and thus the response time of NMP systems a priori. To do this, we introduce two sliding lines which are in charge of control in turn. One is used to stabilize the system and achieve asymptotic regulation eventually like the conventional sliding mode methods and the other to stably control the magnitude of undershoot from the beginning of control until the state meets the first sliding line. This control scheme will be proved to have an asymptotic regulation property. The computer simulation shows that the proposed control scheme is very effective and suitable for controlling the second order NMP system because it can decide the magnitude of undershoot in a direct and stable way and reduce the response time compared with the conventional ones.

Verification of an Autonomous Decentralized UPS System with Fast Transient Response Using a FPGA-Based Hardware Controller

  • Yokoyama, Tomoki;Doi, Nobuaki;Ishioka, Toshiya
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.507-515
    • /
    • 2009
  • This paper proposes an autonomous decentralized control for a parallel connected uninterruptible power supply (UPS) system based on a fast power detection method using a FPGA based hardware controller for a single phase system. Each UPS unit detects only its output voltage and current without communications signal exchange and a quasi dq transformation method is applied to detect the phase and amplitude of the output voltage and the output current for the single phase system. Fast power detection can be achieved based on a quasi dq transformation, which results in a realization of very fast transient response under rapid load change. In the proposed method, the entire control system is implemented in one FPGA chip. Complicated calculations are assigned to hardware calculation logic, and the parallel processing circuit makes it possible to realize minimized calculation time. Also, an Nios II CPU core is implemented in the same FPGA chip, and the software can be applied for non-time critical calculations. Applying this control system, an autonomous decentralized UPS system with very fast transient response is realized. Feasibility and stable operation are confirmed by means of an experimental setup with three UPSs connected in parallel. Also, rapid load change is applied and excellent performance of the system is confirmed in terms of transient response and stability.

치료적 방법을 연부조직 손상단계에 따라 사용하기 위한 지침에 관한 연구 (Study on Guidelines for Using Therapeutic Modalities According to Injury Phases of Soft Tissue)

  • 권원안;김식현;전경희
    • The Journal of Korean Physical Therapy
    • /
    • 제12권3호
    • /
    • pp.497-507
    • /
    • 2000
  • This study was performed to understanding on guidelines for using therapeutic modalities according to injury phases of soft tissue. Clinical decisions on how and when therapeutic modalities may be used should be based on recognition of signs and symptoms. as well as some awareness of the time frames associated with the various phases of the Healing process. The physical therapist must have a sound understanding of that process in terms of the sequence of the various process of healing stage. The results of this study are as follows: 1. Once an acute injury has occured, the healing process consists of the imflammatory response phase, the fibroblastic-repair phase, and the maturation-remodeling phase and can impede by various pathologic factors. 2. Modality use in the initial acute injury phase and the inflammatory response phase should be directed toward limiting the amount of swelling and reducing pain. 3. Modality use in the Fibroblastic repair phase may be change from cold to heat. The purpose of heat is to increase circulation to the injured area to promote healing. 4. During the Maturation-Remodeling phase, some type of heating modalities, ultrasound, or short wave and microwave diathermy should be used to increase circulation to the deeper tissue. In this phases, physical therapists must control training and conditioning habits to allow the injury to heal sufficiently.

  • PDF

벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석 (The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer)

  • 김광호;정종만;나완수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

초기 추력편향제어를 위한 자세각제어 구조에 대한 연구 (A Research of Attitude Angle Control Structure for Thrust Vector Control of Missiles at Initial Boosting Phase)

  • 김부민;황익호
    • 전기학회논문지
    • /
    • 제66권10호
    • /
    • pp.1523-1531
    • /
    • 2017
  • In general, the thrust vector control should be fast and stable in the initial launch phase. Two types of conventional controllers, one is for pitch angle control and the other is for pitch rate control, are designed based on the equation of motion without aerodynamics and are compared in the viewpoints of the stability margin and the time response performance. Also analyzed are the rejection capabilities to cope with high aerodynamic disturbances caused by high angle of attacks in initial booting phase. Additionally, time response features at actuator saturation are investigated. Based on those results, we suggest a controller structure which is more suitable for thrust vector control of missiles at initial booting phase.

스텝핑 모터 특성에 따른 2축 짐발 안테나 시스템의 미소진동 측정 시험 (Micro-Vibration Test on a Two-Axis Gimbal Antenna System with Stepping Motors)

  • 김대관;최홍택;박지용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.420-424
    • /
    • 2012
  • A 2-axis gimbal system is one of main disturbance sources affecting on image jitter response of a satellite. The gimbal system can be rotated on its azimuth and elevation axes, resulting in variation of its moment of inertia and structural modes, so that generates non-linear vibration characteristics. In order to estimate the jitter response, it is an indispensable process to characterize micro-vibration disturbance of the 2-axis gimbal system. In the present research, the vibration characteristics of the 2-axis gimbal system was investigated with respect to the types of stepping motors. The micro-vibration tests were performed for 2-phase and 5-phase stepping motors. The test results show that the disturbance can be reduced with vibration attenuation ratio of 60% by replacing the 2-phase stepping motor with the 5-phase one.

  • PDF

Investigation of hyperbolic dynamic response in concrete pipes with two-phase flow

  • Zheng, Chuanzhang;Yan, Gongxing;Khadimallah, Mohamed Amiine;Nouri, Alireza Zamani;Behshad, Amir
    • Advances in concrete construction
    • /
    • 제13권5호
    • /
    • pp.361-365
    • /
    • 2022
  • The objective of this study is to simulate the two-phase flow in pipes with various two-fluid models and determinate the shear stress. A hyperbolic shear deformation theory is used for modelling of the pipe. Two-fluid models are solved by using the conservative shock capturing method. Energy relations are used for deriving the motion equations. When the initial conditions of problem satisfied the Kelvin Helmholtz instability conditions, the free-pressure two-fluid model could accurately predict discontinuities in the solution field. A numerical solution is applied for computing the shear stress. The two-pressure two-fluid model produces more numerical diffusion compared to the free-pressure two-fluid and single-pressure two-fluid models. Results show that with increasing the two-phase percent, the shear stress is reduced.

Active Response Model and Scheme to Detect Unknown Attacks

  • Kim, Bong-Han;Kim, Si-Jung
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.294-300
    • /
    • 2008
  • This study was conducted to investigate what to consider for active response in the intrusion detection system, how to implement active response, and 6-phase response models to respond actively, including the active response scheme to detect unknown attacks by using a traffic measuring engine and an anomaly detection engine.

주요 우울증에서 혈중 Cytokine과 임상적 호전과의 관계 (The Relationship between the Serum Cytokine and Clinical Improvement in Major Depressive Disorder)

  • 김현철;이상규;김도훈;손봉기
    • 생물정신의학
    • /
    • 제10권1호
    • /
    • pp.70-79
    • /
    • 2003
  • Object : Currently, the alteration of cytokine system has been known to play an important role in regard to depressive symptom. We focused on the relationship between immunological parameters and clinical improvement in major depressive disorder. Method : Data were collected on 26 patients with major depressive disorder using a 8-week prospective follow-up design. After 8-week treatment period with fluoxetine, patients were classified into a response group and a non-response group according to their psychopathological outcome as evaluated by Hamilton Depression Rating Scale. The differences of the immunological parameters between pre-treatment phase and post-treatment phase were compared among patients. The difference of those was also compared within each phase among them. The relationship between socio-demographic variables, depression, cytokine, mononuclear cells was examined by correlation analysis. Multiple regression analyses were performed to explore the predictors of clinical improvement of major depressive disorder. Result : Pre-treatment levels of IL-$1{\beta}$ in the response group were significantly higher than those in the non-response group. Pre-treatment levels of IL-$1{\beta}$ of all patients and in the response group were positively correlated with pre-treatment monocyte counts. Patients with subsequent remission showed significantly lower IL-6 values at baseline than those with non-response. Post-treatment values of IL-6 did not differ significantly among the patients. The correlation test showed more frequent relations among cytokines and mononuclear cells in the response group than in the non-responder group. Especially, serum level of IL-6 in pre-treatment phase was only significantly correlated with HAMD score after 8-week treatement phase, while other cytokines and mononuclear cells were not. Pretreatment level of IL-6 was of paramount importance in predicting clinical improvement of depressive symptom. Conclusion : The immune system of major depressive disorder patients might dichotomize the patients into subsequent responders and non-responders. Immune system might be of great influence on the clinical improvement of major depressive disorder. The mode of interaction between depression and cellular immune function and the mediators responsible for the cytokine production need to be studied further.

  • PDF

동기 제어되는 동압 베어링의 동특성에 관한 연구 (A Study on Dynamic Characteristics of Synchronously Controlled Hydrodynamic Journal Bearing)

  • 노병후;김경웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.311-315
    • /
    • 2001
  • In this paper synchronous whirl of bearing is employed as control algorithm of actively controlled hydrodynamic journal bearing to suppress the whirl instability and unbalance response of a rotor-bearing system. Also, the cavitation algorithm implementing the Jakobsson-Floberg-Olsson boundary condition is adopted to predict cavitation regions in the fluid film more accurately than conventional analysis which uses the Reynolds condition. The stability and unbalance responses of a rotor-bearing system are investigated for various control gain and phase difference between the bearing and journal motion. It is shown that the unbalance response of a rotor-bearing system can be greatly improved by synchronous whirl of the bearing, and there is an optimum phase difference, which gives the minimum unbalance response of the system, at given operating condition. It is also found that the speed at onset of instability can be greatly increased by synchronous whirl of the bearing.

  • PDF