• Title/Summary/Keyword: phase residuals

Search Result 23, Processing Time 0.028 seconds

Outward Testing Procedure for the Identification of Multiple Outliers (다수 이상치 인식(認識)을 위한 외향성 검정 절차)

  • Yum, Joon-Keun;Kim, Jong-Woo
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.3
    • /
    • pp.50-64
    • /
    • 1996
  • This article is concerned with procedures for detecting multiple y outliers in linear regression. The outward-testing procedure, which is controled by the initial subset and the minimum residuals, is suggested by two phases. The performance of this procedure is compared with others by Monte Carlo techniques and found to be superior. The procedure, however, fails in detecting y outliers that are on high-leverage cases in Phase 1. Thus, we proposed ELMS algorithm for a set of suspect observations, in Phase 1. In Phase 2, the proposed testing is conducted using the studentized residuals to see which of the suspect cases are outliers. Several examples are analyzed.

  • PDF

A Comparison of Broadcast and Final Orbits on GPS Delays in GPS-VLBI Hybrid Observation

  • Kwak, Younghee;Cho, Jungho;Kondo, Tetsuro;Takiguchi, Hiroshi;Amagai, Jun;Gotoh, Tadahiro;Sekido, Mamoru;Ichikawa, Ryuichi;Kim, Tuhwan;Sasao, Tetsuo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.65-75
    • /
    • 2012
  • We carry out an error analysis of 24-hour global positioning system (GPS)-very long baseline interferometry (VLBI) (GV) hybrid observation data. In this paper, we focus on the impacts of broadcast and final orbits on the GPS delays of the GV hybrid observation by analyzing the residuals, observed - calculated (O-C) values. The residuals show apparent and consistent biases for L1 and L2 signals, respectively. The scatters of the residuals are around a few nanoseconds. The main cause of those observation errors is the absence of the GPS phase and delay calibration system. Most of the satellites show that the differences between the delays, to which broadcast and final orbits are applied, are about 100 times smaller than the current GV hybrid observation errors. We conclude that GPS delays are not greatly affected by orbit accuracies.

EVALUATION OF DATA QUALITY OF PERMANENT GPS STATIONS IN SOUTH KOREA

  • Park, Kwan-Dong;Kim, Ki-Nam;Lim, Hyung-Chul;Park, Pil-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.367-376
    • /
    • 2002
  • As of September 2002, there are more than 60 operational permanent Global Positioning System (GPS) stations in South Korea. Their data are being used for a variety of purposes: geodynamics, geodesy, real-time navigation, atmospheric science, and geography. Especially, many of the sites are reference stations for DGPS (Differential GPS). However, there has been no comprehensive and qualitative analysis published to evaluate the data quality. In this study, we present preliminary results of our assessment of the permanent GPS sites in South Korea. We have analyzed the multi-path characteristics of each station using a quality-checking software package called TEQC. Another multipath analysis tool based on post-fit phase residuals was used to check the repeating patterns and the amount of the multipath at each site. The long-term stability of each station was analyzed using the root-mean-square (RMS) error of the estimated site positions for one year, which enabled us to evaluate the mount stability. In addition, the number of cycle slips at each site was derived by TEQC. Based on these series of tests, we compared the stability and data quality of permanent GPS stations in South Korea.

Variance estimation of a double expanded estimator for two-phase sampling

  • Mingue Park
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.4
    • /
    • pp.403-410
    • /
    • 2023
  • Two-Phase sampling, which was first introduced by Neyman (1938), has various applications in different forms. Variance estimation for two-phase sampling has been an important research topic because conventional variance estimators used in most softwares are not working. In this paper, we considered a variance estimation for two-phase sampling in which stratified two-stage cluster sampling designs are used in both phases. By defining a conditionally unbiased estimator of an approximate variance estimator, which is calculable when all elements in the first phase sample are observed, we propose an explicit form of variance estimator of the double expanded estimator for a two-phase sample. A small simulation study shows the proposed variance estimator has a negligible bias with small variance. The suggested variance estimator is also applicable to other linear estimators of the population total or mean if appropriate residuals are defined.

Estimation of Hydraulic Characteristics and Prediction of Groundwater Level in the Eastern Coastal Aquifer of Jeju Island (제주도 동부 해안대수층의 수리특성 산정과 지하수위 예측)

  • Jo, Si-Beom;Jeon, Byung-Chil;Park, Eun-Gyu;Choi, Kwang-Jun;Song, Sung-Ho;Kim, Gi-Pyo
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.661-672
    • /
    • 2014
  • Due to tidal force, it is very difficult to estimate the hydraulic parameters of high permeable aquifer near coastal area in Jeju Island. Therefore, to eliminate the impact of tidal force from groundwater level and estimate the hydraulic properties, tidal response technique has been mainly studied. In this study we have extracted 38 tidal constituents from groundwater level and harmonic constants including frequency, amplitude, and phase of each constituent using T_TIDE subroutine which is used to estimate oceanic tidal constituents, and then we have estimated hydraulic diffusivity associated with amplitude attenuation factor(that is the ratio of groundwater level amplitude to sea level amplitude for each tidal constituent) and phase lag(that is phase difference between groundwater level and sea level for each constituent). Also using harmonic constants for each constituent, we made the sinusoidal wave and then we constructed the synthesized wave which linearly combined sinusoidal wave. Finally, we could get residuals(net groundwater level) which was excluded most of tidal influences by eliminating synthesized wave from raw groundwater level. As a result of comparing statistics for synthesized level and net groundwater level, we found that the statistics for net groundwater level was more insignificant than those of synthesized wave. Moreover, in case of coastal aquifer which the impact of tidal force is even more than those of other environmental factors such as rainfall and groundwater yield, it is possible to predict groundwater level using synthesized wave and regression analysis of residuals.

The Latest Performance of Galileo Kinematic PPP at DAEJ Reference Station in South Korea

  • Choi, Byung-Kyu;Yoo, Sung-Moon;Roh, Kyoung-Min;Park, Pilho;Park, Jong-Uk
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • In October 2019, the European Galileo navigation system operates a total of 24 satellites, two of them are in the testing phase. There are enough satellites in operation to enable precise point positioning (PPP) using Galileo signals. The number of visible satellites for Galileo in South Korea is investigated. In addition, to assess the latest performance of the Galileo kinematic PPP, data received at DAEJ reference station from October 1 to October 7, 2019, are analyzed. Galileo kinematic PPP presents some results in two categories, single-frequency PPP (SPPP) and dual-frequency PPP (DPPP). The positioning accuracy for Galileo kinematic SPPP solutions is less than 1 m root mean square (RMS) in all direction components. The Galileo kinematic DPPP achieves the positioning accuracy with an RMS value of less than 7 cm in all direction components. The results show that the latest performance of Galileo kinematic PPP at DAEJ station in South Korea is still relatively poor compared to GPS kinematic PPP. However, the residuals of Galileo code measurements are smaller than those of GPS code measurements.

Analytical solution to the conduction-dominated solidification of a binary mixture (열전도에 의해 지배되는 이성분혼합물의 응고문제에 대한 해석해)

  • Jeong, Jae-Dong;Yu, Ho-Seon;No, Seung-Tak;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3655-3665
    • /
    • 1996
  • An analytical solution is presented for the conduction-dominated solidification of a binary mixture in a semi-infinite medium. The present approach differs from that of other solution by these four characteristics. (1) Solid fraction is determined from the phase diagram, (2) thermophysical properties in mushy zone are weighted according to the local solid fraction, (3) non-equilibrium solidification can be simulated and (4) the cooling condition of under-eutectic temperature can be simulated. Up to now, almost all analyses are based on the assumption of constant properties in mushy zone and solid fraction linearly with temperature or length. The validation for these assumptions, however, shows that serious error is found except some special cases. The influence of microscopic model on the macroscopic temperature profile is very small and can be ignored. But the solid fraction and average solid concentration which directly influence the quality of materials are drastically changed by the microscopic models. An approximate solution using the method of weighted residuals is also introduced and shows good agreement with the analytical solution. All calculations are performed for NH$_{4}$Cl-H$_{2}$O and Al-Cu system.

Concentration and Environmental Loading of Veterinary Antibiotics in Agricultural Irrigation Ditches

  • Kim, Sung-Chul;Chung, Doug Young;Kim, Kye Hoon;Lee, Ja Hyun;Kim, Hyo Kyung;Yang, Jae E.;Ok, Yong Sik;Almarwei, Yaser A.O.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.867-876
    • /
    • 2012
  • The concentration of veterinary antibiotics in aqueous and sediment matrices was measured in agricultural irrigation ditches bordering several animal-feeding operations (AFOs) and then compared to its concentration in the watershed. Analytical determination in aqueous samples was based on solid phase extraction (SPE) and appropriate buffer solutions were used to extract residuals in sediment samples. Separation and detection of extracted veterinary antibiotics were performed with high performance liquid chromatograph tandem mass spectrometry (HPLC/MS/MS). In general, higher concentrations of antibiotic were observed in the aqueous phase of irrigation ditches, with the highest concentration of erythromycin hydrochloride (ETM-$H_2O$) of $0.53{\mu}g\;L^{-1}$, than in aqueous watershed samples. In contrast, higher concentrations were measured in river sediment than in irrigation ditch sediment with the highest concentration of oxytetracycline of $110.9{\mu}g\;kg^{-1}$. There was a high calculated correlation ( > 0.95) between precipitation and measured concentration in aqueous samples from the irrigation ditches for five of the ten targeted veterinary antibiotics, indicating that surface runoff could be an important transport mechanism of veterinary antibiotics from field to environment. Further, environmental loading calculation based on measured concentrations in aqueous samples and flow information clearly showed that irrigation ditches were 18 times greater than river. This result suggests the likelihood that veterinary antibiotics can be transported via irrigation ditches to the watershed. The transport via surface runoff and likely environmental loading via irrigation ditches examined in this study helps identify the pathway of veterinary antibiotics residuals in the environment.

Effects of Parameter Estimation in Phase I on Phase II Control Limits for Monitoring Autocorrelated Data (자기상관 데이터 모니터링에서 일단계 모수 추정이 이단계 관리한계선에 미치는 영향 연구)

  • Lee, Sungim
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.5
    • /
    • pp.1025-1034
    • /
    • 2015
  • Traditional Shewhart control charts assume that the observations are independent over time. Current progress in measurement and data collection technology lead to the presence of autocorrelated process data that may affect poor performance in statistical process control. One of the most popular charts for autocorrelated data is to model a correlative structure with an appropriate time series model and apply control chart to the sequence of residuals. Model parameters are estimated by an in-control Phase I reference sample since they are usually unknown in practice. This paper deals with the effects of parameter estimation on Phase II control limits to monitor autocorrelated data.

Sensor Fault Detection, Localization, and System Reconfiguration with a Sliding Mode Observer and Adaptive Threshold of PMSM

  • Abderrezak, Aibeche;Madjid, Kidouche
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1012-1024
    • /
    • 2016
  • This study deals with an on-line software fault detection, localization, and system reconfiguration method for electrical system drives composed of three-phase AC/DC/AC converters and three-phase permanent magnet synchronous machine (PMSM) drives. Current sensor failure (outage), speed/position sensor loss (disconnection), and damaged DC-link voltage sensor are considered faults. The occurrence of these faults in PMSM drive systems degrades system performance and affects the safety, maintenance, and service continuity of the electrical system drives. The proposed method is based on the monitoring signals of "abc" currents, DC-link voltage, and rotor speed/position using a measurement chain. The listed signals are analyzed and evaluated with the generated residuals and threshold values obtained from a Sliding Mode Current-Speed-DC-link Voltage Observer (SMCSVO) to acquire an on-line fault decision. The novelty of the method is the faults diagnosis algorithm that combines the use of SMCSVO and adaptive thresholds; thus, the number of false alarms is reduced, and the reliability and robustness of the fault detection system are guaranteed. Furthermore, the proposed algorithm's performance is experimentally analyzed and tested in real time using a dSPACE DS 1104 digital signal processor board.