• Title/Summary/Keyword: phase matching

Search Result 409, Processing Time 0.031 seconds

Extended Kalman Filtering for I.M.U. using MEMs Sensors (반도체 센서의 확장칼만필터를 이용한 자세추정)

  • Jeon, Yong-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.469-475
    • /
    • 2015
  • This paper describes about the method for designing an extended Kalman filter to accurately measure the position of the spatial-phase system using a semiconductor sensor. Spatial position is expressed by the correlation of the rotated coordinate system attached to the body from the inertia coordinate system (a fixed coordinate system). To express the attitude, quaternion was adapted as a state variable, Then, the state changes were estimated from the input value which was measured in the gyro sensor. The observed data is the value obtained from the acceleration sensor. By matching between the measured value in the acceleration sensor and the predicted calculation value, the best variable was obtained. To increase the accuracy of estimation, designation of the extended Kalman filter was performed, which showed excellent ability to adjust the estimation period relative to the sensor property. As a result, when a three-axis gyro sensor and a three-axis acceleration sensor were adapted in the estimator, the RMS(Root Mean Square) estimation error in simulation was retained less than 1.7[$^{\circ}$], and the estimator displayed good property on the prediction of the state in 100 ms measurement period.

Domain formation and expansion during periodic poling of congruent $LiNbO_3$ using external field (조화용융조성 $LiNbO_3$의 주기적 분극 반전 동안 도메인 생성 및 이동에 관한 연구)

  • Kwon, S.W.;Yang, W.S.;Lee, H.M.;Kim, W.K.;Lee, H.Y.;Yoon, D.H.;Song, Y.S.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.2
    • /
    • pp.53-58
    • /
    • 2006
  • When external field was applied to congruent $LiNbO_3$, it was investgated for domain formation and expansion of $LiNbO_3$. The domain wall velocities of 0.5 mm thickness $LiNbO_3$ were 28.70, 16.02 and $5.75{\mu}m/sec$ under poling field of 23.5, 22.0 and 21.0 kV/mm, respectively. As $1 M{\Omega}$ resistor was used in domain inversion system, harmonic domain inversion was not achieved by rapid domain expansion. And 50% duty cycle periodically poled $LiNbO_3$ have been fabricated by charge control using $10 M{\Omega}$ resistor.

A Simulation Study of Atomic Resolution TEM images for Two Dimensional Single Layer and Bilayer Graphene Crystal (2차원적인 단층 및 복층 그래핀 결정에 대한 원자분해 투과전자현미경 영상 시뮬레이션 연구)

  • Kim, Hwang-Su
    • Applied Microscopy
    • /
    • v.40 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • In a simulation study of atomic resolution transmission electron microscope images of single layer and bilayer graphene, it is demonstrated that the conventional Bloch wave formulations can be used when high-order Laue zone reflections are properly taken into account in the theory. The simulated images for bilayer graphene show 3-fold rotational lattice symmetry rather than the 6-fold one under certain conditions. This result can be understood as revealed the 3-fold rotational lattice symmetry of bilayer graphene in three dimensions along [0001]. For single layer graphene the observed phase images showing 3-fold rotational lattice symmetry were particularly noted. This phenomenon has been explained by an assumption of the re-configuration of electron density on the surface of graphene. And the matching images have been obtained as simulated with up to the second order Laue zone reflections only, reflecting the re-configuration of electrons on the surface.

Palm-Size-Integrated Microwave Power Module at 1.35-GHz for an Atmospheric Pressure Plasma for biomedical applications

  • Myung, C.W.;Kwon, H.C.;Kim, H.Y.;Won, I.H.;Kang, S.K.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.498-498
    • /
    • 2013
  • Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.

  • PDF

Study on Retrodirective Cross-eye Structure using Linear Phased Array Antenna (선형 위상배열 안테나를 이용한 역지향성 크로스아이 구조에 관한 연구)

  • Kim, In-seon;Park, Jintae;Kim, Ghiback;Park, Beomjun;Jang, Yeonsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2020
  • This study proposes a novel structure for the cross-eye, one of the representative jamming techniques of monopulse sensors. The proposed jammer tranceivers are composed of multi-channels with phased array antenna. We named this structure PRCJ(Phased array Retrodicetive Cross-eye Jammer). In this structure, formulas for calculating cross-eye gain and distance error are derived. We compare the properties of PRCJ with two-element retrodiredtive cross-eye jammer(TRCJ). PRCJ can achieve higher J/S because this structure can steer the spatially combined jamming signal in the direction of the incident monopulse signal. Because of the multiple channels in the phased array, it also increases the degree of freedom of channel matching. Finally, We preform a statistical analysis of the cross-eye gain according to the amplitude and phase errors. From this results, It has been found that PRCJ can get higher cross-eye gain than TRCJ.

Development of Porous polyurethane Arterial-Venous Shunt by Thermal Phase Transition (온도 변화에 의한 상전이를 이용한 다공성 동정맥 누관의 개발)

  • Ryu, G.H.;Jeong, J.S.;Jeong, H.K.;Lee, H.K.;Lee, K.B.;Kim, J.;Min, B.G.;Lee, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.447-450
    • /
    • 1997
  • A new technique for the preparation of porous vascular prostheses was investigated. Polyurethane solution (10 to 14wt%) was injected into a mold. After freezing at low temperature $(0^{\circ}C\sim-40^{\circ}C)$, solvent was dissolved out with water at $0^{\circ}C$ to form porous tubes. The average pore size $(<10{\mu}m)$and pore occupation (10% to 51%) were easily changed by changing polyurethane concentration, freezing temperature, and freezing methods. This technique can give a proper pore size $(30\sim60{\mu}m)$ for tissue ingrowth, and suitable compliances for matching with arteries and veins. This method might give a desired compliant graft for artificial implantation with the presently valid medical polymers.

  • PDF

The fabrication of a coaxial line impedance transformer with low transmission loss and wideband operation range (저손실 광대역 동작 특성을 가지는 동축 선로 임피던스 변환기 제작)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2241-2248
    • /
    • 2017
  • The coaxial line impedance transformer that performs impedance conversion using the coupling of two or more coaxial lines of the same length is often used for impedance matching in the low frequency region due to many advantages. This paper measures the phase and magnitude characteristics of each coaxial line in a 4:1 coaxial line impedance transformer using two 100mm coaxial lines. This experiment shows that it is more effective to make the length of the auxiliary coaxial line shorter than the main coaxial line by about 5 mm in order to realize a low loss impedance transformer. In addition, it measures the transmission characteristics by directly connecting a 4:1 impedance transformer and a 1:4 impedance transformer. This experiment shows that it is effective to connect a 1pF capacitor between the ground and the outer conductor input point of the main coaxial line in order to increase the operating frequency range.

Fluoride single crystals for UV/VUV nonlinear optical applications

  • Shimamura Kiyoshi;Villora Encarnacion G.;Muramatsu Kenichi;Kitamura Kenji;Ichinose Noboru
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.4
    • /
    • pp.133-140
    • /
    • 2006
  • The growth characteristics and properties of large size $SrAlF_5$ single crystals are described and compared with those of $BaMgF_4$. Transmission spectra in the vacuum ultraviolet wavelength region indicate a high transparency of $SrAlF_5$ (about 90% without considering surface reflection loses) down to 150 nm, on contrast to the optical loses observed for $BaMgF_4$. The ferroelectric character of $SrAlF_5$ is evidenced by the reversal of the spontaneous polarization in a hysteresis loop. The higher potential of $SrAlF_5$ in comparison with $BaMgF_4$ for the realization of all-solid-state lasers in the ultraviolet wavelength region by the quasi-phase matching (QPM) technique is pointed out. $SrAlF_5$, besides a higher grade of transparency, shows a nonlinear effective coefficient similar to that of quartz and uniaxial nature, on contrast to the one order smaller nonlinear coefficient and biaxial character of $BaMgF_4$. The refractive index of $SrAlF_5$ from the ultraviolet to the near-infrared wavelength region is measured by the minimum deviation method. The Sellmeier and Cauchy coefficients are obtained from the fits to the curves of the ordinary and extraordinary refractive indices, and the grating period for the first order QPM is estimated as a function of the wavelength. The poling periodicity for 193 nm SHG from 386 nm is $4{\mu}m$.

Very High Linearity of High Power Amplifier by Reduction of $2^{nd}$, $3^{rd}$ Harmonics and Predistortion of $3^{rd}$ IMD (3차 혼변조 신호의 전치왜곡과 2, 3차 고조파 억제를 통한 고선형성 고출력 전력 증폭기에 관한 연구)

  • Lee, Chong-Min;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.50-54
    • /
    • 2011
  • In this article, the linearity of single power amplifier is improved by suppress $2^{nd}$ and $3^{rd}$ harmonics at output port of high power amplifier and by cancelling of $3^{rd}$ IMD. The matching network in order to suppress harmonics consists of metamaterial like the CRLH. The $2^{nd}$ and $3^{rd}$ harmonics are suppressed over 27 dBc, respectively. A phase of generated $3^{rd}$ IMD at output of DPA (drive power amplifier) has changed in order to offset the $3^{rd}$ IMD of HPA (high power amplifier). The harmonics of the proposed PAM suppress over 6 dB than single HPA. The PAM has a 36.98 dBm of the output power, 21.6 dB of the power gain and 29.4 % of the PAE. The harmonics is a -53 dBc about PAM. This result indicate that a harmonic level is lower 20 dB than reference power amplifier.

Differential Protein Expression in EC304 Gastric Cancer Cells Induced by Alphastatin

  • Wang, Xin-Xin;Sun, Rong-Ju;Wu, Meng;Li, Tao;Zhang, Yong;Chen, Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1667-1674
    • /
    • 2012
  • Objective: To explore the differential protein expression profile in EC304 gastric cancer cells induced by alphastatin. Methods: Cultured EC304 cells in the exponential phase of growth were randomly divided into alphastatin and control groups. Total proteins were extracted and the two dimensional electrophoresis (2-DE) technique was applied to analyze differences in expression with ImageMaster 2D Platinum 5.0 software. Proteins were identified using the MASCOT database and selected differently expressed proteins were characterised by western blotting and immunofluorescence. Results: $1350{\pm}90$ protein spots were detected by the ImageMaster software in the 2-DE gel images from the control and alphastatin groups. The match rate was about 72-80% for the spectrum profiles, with 29 significantly different protein spots being identified, 10 upregulated, 16 downregulated, two new and one lost. The MASCOT search scores were 64-666 and the peptide matching numbers were 3-27 with sequence coverage of 8-62%. Twenty-three proteins were checked by mass spectrometry, including decrease in Nm23 and profilin-2 isoform b associated with the regulation of actin multimerisation induced by extracellular signals. Conclusion: The proteome in EC304 cells is dramatically altered by alphastatin, which appears to play an important role in modulating cellular activity and anti-angiogenesis by regulating protein expression and signal transduction pathways through Nm23 and profilin-2 isoform b, providing new research directions for anti-angiogenic therapy of gastric cancer.