Design of Ku-Band Phase Locked Harmonic Oscillator (Ku-Band용 위상 고정 고조파 발진기 설계)

  • Lee Kun-Joon;Kim Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.49-55
    • /
    • 2005
  • In this paper, the phase locked harmonic oscillator(PLHO) using the analog PLL(Phase Locked Loop) is designed and implemented for a wireless LAN system. The harmonic oscillator is consisted of a ring resonator, a varactor diode and a PLL circuit. Because the fundamental fiequency of 8.5 GHz is used as the feedback signal for the PLL and the 2nd harmonic of 17.0 GHz is used as the output, a analog frequency divider for the phase comparison in the PLL system can be omitted. For the simple PLL circuit, the SPD(Sampling Phase Detector) as a phase comparator is used. The output power of the phase locked harmonic oscillator is 2.23 dBm at 17 GHz. The fundamental and 3rd harmonic suppressions are -31.5 dBc and -29.0 dBc, respectively. The measured phase noise characteristics are -87.6 dBc/Hz and -95.4 dBc/Hz at the of offset frequency of 1 kHz and 10 kHz from the carrier, respectively.

Design of Phase Locked Dielectric Resonator Oscillator with Low Phase Noise for X-band (저위상잡음을 갖는 X-band용 위상고정 유전체 공진 발진기의 설계 및 제작)

  • 류근관
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.34-40
    • /
    • 2004
  • The PLDRO(Phase-Locked Dielectric Resonator Oscillator) with low phase noise is designed for X-band. The phase of VCDRO(Voltage Controlled Dielectric Resonator Oscillator) is locked to that of a high stable reference oscillator by using a SPD(Sampling Phase Detector) to improve phase noise performance in the loop bandwidth. And, the VCDRO is implemented using a high impedance inverter coupled with dielectric resonator to improve the phase noise performance out of the loop bandwidth. This PLDRO exhibits the harmonic rejection characteristics of 51.67㏈c and requires below 1.95W. The phase noise characteristics are performed as -107.17㏈c/Hz at 10KHz offset frequency and -113.0㏈c/Hz at 100KHz offset frequency, respectively, at ambient. And the output power of 13.0㏈m${\pm}$0.33㏈ is measured over the temperature range of $-20 ∼ +70^{\circ}C$ .

Hue-based Noise-tolerant Corner Detector Robust to Shadows (그림자에 강건한 색상 기반 내잡음성 코너 검출자)

  • 박기현;박은진;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.239-245
    • /
    • 2004
  • A hue-based noise-tolerant corner detector is proposed for the exact detection of the real corners in spite of the shadows and random noise. Based on the fact that the hue gradient at the border of the opaque objects' shadow is smaller than the intensity gradient in HSI (hue-saturation-intensity) color space, the effects of shadow are eliminated by introducing the hue-weighted combination of vector gradient to the proposed corner detector. Furthermore, the proposed corner detector is robust to random noise by offsetting the contribution to the corner candidate when the polarities of the color gradients of the pixel pairs are out of phase each other. Results of the experiment show that the proposed corner detector can effectively detect the real corners.

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF

Design of Dual PFD with Improved Phase Locking Time (위상동기시간을 개선한 Dual PFD 설계)

  • 이준호;손주호;김선홍;김동용
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.275-278
    • /
    • 1999
  • In this paper, Dual PFD(Phase Frequency Detector) with improved phase locking time is proposed. The proposed PFD consists of positive and negative edge triggered D flip-flop. In order to confirm the characteristics of proposed PFD, HSPICE simulations are performed using a 0.25${\mu}{\textrm}{m}$ CMOS process. As a result of simulations, the proposed PFD has a characteristic of fast phase locking time with dead zone free.

  • PDF

New phase/frequency detectors for high-speed phase-locked loop application (고속 위상 동기 루프를 위한 새로운 구조의 위상/주파수 검출기)

  • 전상오;정태식;김재석;최우영
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.8
    • /
    • pp.52-59
    • /
    • 1998
  • New types of PFD (phase-frequency detector) are proposed with reset time and propagation delay reduced. The perfomrance of our proposed PFDs are confirmed by SPICE simulation with 0.8.mu.m CMOS process parameter. As a result of simulation, the reset time of PFDs are 0.32 nsec and 0.030 nsec in capture-process. The proposed PFDs can be used in hihg-speed phase-licked loop (PLL).

  • PDF

Analysis of Partial Discharge Patterns in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 부분방전 패턴의 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1015-1018
    • /
    • 1999
  • Partial discharge patterns were analyzed in the pumped storage generator stator winding. These were measured using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). Slot discharge was discovered in phase A. Discharges at conductor surface were occurred in phase B and in Phase C. Partial discharge patterns from on-line PDA system were compared with those off-line PDD system. The results of two systems are very same in phase A, B and C.

  • PDF

Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples (HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석)

  • Kwak, Sun Young;Moon, Myeong Hee;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.519-528
    • /
    • 2006
  • An analytical method for the determination of thyroid hormones in urine samples has been studied by using solid-phase extraction and high-performance liquid chromatography/diode array detector/electro-spray mass spectrometry. Seven thyroid hormones were successfully separated by gradient elution on the reverse phase Hypersil ODS column (4.6 mm I.D., 100 mm length, particle size $5{\mu}m$) with ammonium formate buffer and acetonitrile, and UV spectra and mass fragment could be confirmed. The extraction recoveries of thyroid hormones in the urine samples (pH 3) were in the range of 89.0-113.1% with solid-phase extraction by C18, followed by elution with 4 ml of methanol/ammonium hydroxide (9 : 1). The calibration curves showed good linearity with the correlation coefficients ($r^2$) varying from 0.992 to 0.998 and the detection limits of all analytes were obtained in the range of 2-4 ng/ml (3.8-13.0 pmol/ml).

Improved Two-Phase Framework for Facial Emotion Recognition

  • Yoon, Hyunjin;Park, Sangwook;Lee, Yongkwi;Han, Mikyong;Jang, Jong-Hyun
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1199-1210
    • /
    • 2015
  • Automatic emotion recognition based on facial cues, such as facial action units (AUs), has received huge attention in the last decade due to its wide variety of applications. Current computer-based automated two-phase facial emotion recognition procedures first detect AUs from input images and then infer target emotions from the detected AUs. However, more robust AU detection and AU-to-emotion mapping methods are required to deal with the error accumulation problem inherent in the multiphase scheme. Motivated by our key observation that a single AU detector does not perform equally well for all AUs, we propose a novel two-phase facial emotion recognition framework, where the presence of AUs is detected by group decisions of multiple AU detectors and a target emotion is inferred from the combined AU detection decisions. Our emotion recognition framework consists of three major components - multiple AU detection, AU detection fusion, and AU-to-emotion mapping. The experimental results on two real-world face databases demonstrate an improved performance over the previous two-phase method using a single AU detector in terms of both AU detection accuracy and correct emotion recognition rate.

The Demodulation for Bipolar Delta Driven GMSK (바이폴라 델타 구동 GMSK에 대한 복조)

  • Bang, Seung-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.10
    • /
    • pp.824-831
    • /
    • 2013
  • The delta driven GMSK is a modulation scheme to generate the gaussian pulse by the bipolar delta signal and to modulate the phase function with the differential gaussian pulse between $+T_b/2$ and $-T_b/2$. The demodulation of delta driven GMSK differs from conventional GMSK schemes. This paper proposed a demodulation with the differential phase detector at the end of each bit interval. A designed detector then finds the one of the possible region by hard decision, in which the phase difference lies. Finally the binary data can be recovered by state transition process. Through the BER simulation for AWGN channel, it was found that the proposed demodulation effected by the run length of binary data. The simulated BER degradation of about 2[dB] was analyzed, as compared to the theoretical coherent demodulation with $BT_b$=0.3.