• 제목/요약/키워드: phase calibration

검색결과 501건 처리시간 0.022초

Evaluation of Phase Calibration Performance with KVN

  • Jung, Dawoon;Sohn, Young-Jong;Byun, Do-Young;Jung, Taehyun
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.36.2-36.2
    • /
    • 2016
  • In mm-VLBI, the quality of observation data is largely affected by atmospheric effect. The most challenging matter is that the phase of correlator output fluctuates rapidly resulting from a variation of atmospheric propagation delay. Consequently, it is demanding to achieve high Signal-to-Noise ratio by integrating data in time domain before calibrating atmospheric delay. However, Korean VLBI Network (KVN) has a unique system to make a 4-frequency (22/43/86/129 GHz) simultaneous observation in mm-wavelength and Frequency Phase Transfer (FPT) calibration technique has effectively removed atmospheric delay in the simultaneous multi-frequency observation of the KVN. For astrometric and astrophysical studies, we evaluated the FPT performance of KVN in various observing conditions. Using the total 38 bright AGNs, we have compared atmospheric conditions such as ground-based weather information, system temperature, atmospheric delay with the calibration results of FPT at 22/43/86/129 GHz during the five experiments in 2013, and quantified its performance in terms of coherence function and Allan variance. We present the analysis result of the relation between the FPT performance and observing conditions.

  • PDF

Measurement of local wall temperature and heat flux using the two-thermocouple method for a heat transfer tube

  • Ahn, Taehwan;Kang, Jinhoon;Jeong, Jae Jun;Yun, Byongjo
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1853-1859
    • /
    • 2019
  • The two-thermocouple method was investigated experimentally to evaluate its accuracy for the measurement of local wall temperature and heat flux on a heat transfer tube with an electric heater rod installed in an annulus channel. This work revealed that a thermocouple flush-mounted in a surface groove serves as a good reference method for the accurate measurement of the wall temperature, whereas two thermocouples installed at different depths in the tube wall yield large bias errors in the calculation of local heat flux and wall temperature. These errors result from conductive and convective changes due to the fin effect of the thermocouple sheath. To eliminate the bias errors, we proposed a calibration method based on both the local heat flux and Reynolds number of the cooling water. The calibration method was validated with the measurement of local heat flux and wall temperature against experimental data obtained for single-phase convection and two-phase condensation flows inside the tube. In the manuscript, Section 1 introduces the importance of local heat flux and wall temperature measurement, Section 2 explains the experimental setup, and Section 3 provides the measured data, causes of measurement errors, and the developed calibration method.

이중 파장 보정방법 기반 다이나믹 분광타원편광계의 안정도 최적화 (Long-term Stability Optimization of Dynamic Spectroscopic Ellipsometery based on Dual-wavelength Calibration)

  • 최인호;헤리저데헌거흐 사이드;최석현;황국현;심준보;김대석
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.178-183
    • /
    • 2021
  • This paper describes a dynamic spectroscopic ellipsometry based on dual-wavelength calibration. DSE provides ellipsometric parameters at rates above 20 Hz, but the interferometer's sensitivity to temperature makes it difficult for that proposed system to maintain stable 𝜟k over long periods of time. To solve this problem, we set up an additional path in the DSE to perform simulations of the polarization phase calibration method using dual wavelengths. Through simulation, we were able to eliminate most of the polarization phase error and maintain a stable 𝜟k in the long-term stability experiment for 10 hours. This is the result that the 𝜟k stability of the proposed system is improved tens of times compared to the existing system.

An online Calibration Algorithm using binary spreading code for the CDMA-based Adaptive Antenna Array

  • Lee, Chong-Hyun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.32-39
    • /
    • 2006
  • In this paper, an iterative subspace-based calibration algorithm for a CDMA-based antenna array in the presence of unknown gain and phase error is presented. The algorithm does not depend on the array geometry and does not require a prior knowledge of the Directions Of Arrival (DOA) of the signals. The method requires the code sequence of a reference user only. The proposed algorithm is based on the subspace method and root finding approach, and it provides estimates of the calibration vector, the DOA and the channel impulse response, by using the code sequence of a reference user. The performance of the proposed algorithm was investigated by means of computer simulations and was verified using field data measured through a custom-built W-CDMA test-bed. The data show that experimental results match well with the theoretical calibration algorithm. Also, teh study propose an efficient algorithm using the simulated annealing technique. This algorithm overcomes the requirement of initial guessing in the subspace-based approach.

실리콘 웨이퍼 휨형상 측정 정밀도 향상을 위한 시스템변수 보정법 (System calibration method for Silicon wafer warpage measurement)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.139-144
    • /
    • 2014
  • As a result of a mismatch of the residual stress between both sides of the silicon wafer, which warps and distorts during the patterning process. The accuracy of the warpage measurement is related to the calibration. A CCD camera was used for the calibration. Performing optimization of the error function constructed with phase values measured at each pixel on the CCD camera, the coordinates of each light source can be precisely determined. Measurement results after calibration was performed to determine the warpage of the silicon wafer demonstrate that the maximum discrepancy is $5.6{\mu}m$ with a standard deviation of $1.5{\mu}m$ in comparison with the test results obtained by using a Form TalySurf instrument.

T-DMB/DAB/FM 수신기를 위한 광대역 델타시그마 분수분주형 주파수합성기 (A Wideband ${\Delta}{\Sigma}$ Frequency Synthesizer for T-DMB/DAB/FM Applications in $0.13{\mu}m$ CMOS)

  • 신재욱;신현철
    • 대한전자공학회논문지SD
    • /
    • 제47권12호
    • /
    • pp.75-82
    • /
    • 2010
  • 본 논문은 다중대역 송수신기 CMOS RFIC 단일 칩을 위한 광대역 델타시그마 분수분주형 주파수합성기에 관한 것이다. 광대역 VCO의 LC Tank에 6-bit Switched Capacitor Array Bank를 작용하여 2340~3940 MHz의 출력주파수 범위를 가지도록 하였으며, 위상동기 전 Capacitor Bank Code를 선택하기위한 VCO Frequency Calibration 회로는 전체 주파수대역에서 $2{\mu}s$이하로 보정을 마치는 뛰어난 성능을 보여준다. 광대역 VCO로부터 T-DMB/DAB/FM Radio의 LO 신호를 생성하기 위해 선택 가능한 다중분주비 ${\div}2$, ${\div}16$, ${\div}32$를 가지는 LO 신호 발생기는 L-Band (1173 ~ 1973 MHz), VHF-III (147 ~ 246 MHz), VFH-II (74~123 MHz)에서 I/Q신호를 생성한다. Integrated Phase Noise는 전체 대역에서 0.8 degree RMS 이하로 측정되어 매우 낮은 위상잡음을 보여주었다. 또한, VCO Frequency Calibration 시간을 포함하는 주파수합성기의 전체 동기시간은 $50{\mu}s$ 이하로 측정되었다. 이 광대역 델타시그마 분수분주형 주파수합성기는 $0.13{\mu}m$ CMOS공정으로 제작되었으며, 1.2 V 전원전압에서 15.8 mA의 전류를 소모한다.

X-밴드 완전 편파 Scatterometer 시스템 보정에 관한 연구 (Study on the Calibration of a Full-Polarimetric Scatterometer System at X-band)

  • 황지환;박성민;권순구;오이석
    • 한국전자파학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-416
    • /
    • 2010
  • 본 논문에서는 X-밴드 대역의 지상운용용 HPS(Hongik Polarimetric Scatterometer) 시스템 보정에 관한 연구 결과를 선보인다. Scatterometer 시스템 보정을 위해 이론적으로 RCS(Radar Cross Section)가 잘 알려진 금속구, 삼각수동 반사기(trihedral corner reflector), 금속봉 등과 같은 보정용 목표물을 이용하여 이론값과 측정값을 비교함으로써 scatterometer 시스템의 왜곡 정도를 분석한다. 실외 환경에서 scatterometer 시스템을 이용하는 실제 측정상황의 보정 정확도는 보정용 목표물의 정확하고 안정된 측정에 의해 좌우되므로 이를 보완하기 위해 HPS 시스템의 입사각(${\xi}-$, ${\phi}-$방향) 제어 기능을 응용한 자동화된 2차원 목표물 스캐닝 측정법(2-D target scanning technique) 을 함께 선보인다. 이때, scatterometer 시스템의 왜곡 정도를 보정하기 위한 기법으로는 GCT(General Calibration Technique) 기법과 STCT(Single Target Calibration Technique) 기법을 비교 연구하였으며, 보정 정확도를 분석하기 위해서 시험용 목표물로 삼각 수동 반사기의 편파별 RCS와 위상차를 측정/비교하였다. 시스템 보정 정도를 검증하기 위해 세 종류(10/20/30 cm)의 삼각수동 반사기를 이용하였으며, 동일 편파 RCS는 GCT 기법과 STCT 기법을 이용하여 각각 ${\pm}1.0$ dB과 ${\pm}0.5$ dB의 오차 범위에서 보정되었다. 또한, 동일 편파간 위상차( ${\phi}_{hh}-{\phi}_{vv}$)는 이론 값과 비교하여 $-20^{\circ}{\sim}0^{\circ}$와 약 ${\pm}5^{\circ}$의 오차를 각각 보였다.

眞圓度 測定器의 誤差特性에 대한 解析 -위상차법- (An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method-)

  • 한응교;허문석;박익근
    • 오토저널
    • /
    • 제10권3호
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

전자기 탐사 시스템 반응의 타당성 확인을 위한 분산 관계식과 힐버트 변환 (Dispersion constraints and the Hilbert transform for electromagnetic system response validation)

  • Macnae, James;Springall, Ryan
    • 지구물리와물리탐사
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2011
  • 상업적인 주파수영역 항공전자탐사 장비의 개별적인 하부시스템의 계기변화와 보정에 대한 점검방법으로 유인성 제약조건만을 사용하여 광대역 이상성분 자료로부터 통상성분을 예측하고자 한다. 이상성분 자료로부터 통상성분의 반응을 예측하는 방법은 다음을 포함한 몇 가지가 있다: (1) 기준면 변화, 보정, 위상의 점검에 대한 품질관리; (2) 이상생분 측정으로부터 통상성분의 잡음수준 예측 및 확인 그리고 향후에는 그 반대과정도 가능할 것이다; (3) 주파수영역과 시간영역의 더 나은 변환과 유인성을 충족시키기 위해 성기게 측정된 자료의 내삽 및 외삽 실제로 수치모형자료와 Resolve 헬리곱터에 탑재된 전자기 탐사 장비로 측정된 주파수 영역 자료에 대한 실험 결과, 통상성분 자료들은 비율을 맞춘 힐버트 변환에 의해서 40에서 80 ppm의 표준편차를 갖고 예측될 수 있다는 것을 알았다. 그러나, 비행간의 기준면들 사이의 상대적인 차이는 1 ppm보다 더 정확히 분석될 수 있으며 이는 계기변화 보정의 정밀도에 대해 독립적인 품질관리를 가능하게 한다.

보정된 Scatterometer의 측정데이터를 사용한 SAR 데이터 교정 (SAR Data Correction Based on Calibrated-Scatterometer Measurements)

  • 정구준;홍진영;오이석
    • 한국전자파학회논문지
    • /
    • 제15권2호
    • /
    • pp.121-126
    • /
    • 2004
  • 본 논문에서는 calibration된 scatterometer를 이용하여 SAR 데이터를 보정하는 연구 결과를 선보인다. 도체구를 이용하여 안테나 주빔에서의 polarimetric한 안테나 패턴(크기와 위상)을 측정하고, 이 데이터를 이용하여 차량 탑재형 네트워크 분석기형 scatterometer 시스템을 polarimetric하게 정확하게 보정하였다. 이 scatterometer를 이용하면 잔디밭, 논, 맨땅 등의 지표면에 대한 정확한 Mueller 행렬을 얻을 수 있으므로, 레이더 산란계수뿐만 아니라 위상변수들도 정확하게 측정하게 된다. 또한, 대부분의 SAR 시스템에는 위상변수 측정에 에러가 있게되고, polarimetric하게 보정된 scatterometer로 SAR가 측정하는 지역을 동시에 측정하여 SAR 데이터를 교정할 수 있다. 이러한 polarimetric한 보정 방법을 이용하면, 산란계수의 보정효과는 크지 않으나, hh-편파와 vv-편파간의 위상변수인 degree of correlation $\alpha$의 보정효과는 매우 큼을 알 수 있었다.