• Title/Summary/Keyword: phase calibration

Search Result 501, Processing Time 0.031 seconds

Adaptive Calibration Method in Multiport Amplifier for K-Band Payload Applications

  • Moon, Seong-Mo;Shin, Dong-Hwan;Lee, Hong-Yul;Uhm, Man-Seok;Yom, In-Bok;Lee, Moon-Que
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.718-721
    • /
    • 2013
  • This letter proposes a novel calibration method for a multiport amplifier (MPA) to achieve optimum port-to-port isolation by correcting both the amplitude and phase of the calibration signals. The proposed architecture allows for the detection of the phase error and amplitude error in each RF signal path simultaneously and can enhance the calibrated resolution by controlling the analog phase shifters and attenuators. The designed $2{\times}2$ and $4{\times}4$ MPAs show isolation characteristics of 30 dB and 27 dB over a frequency range of 19.5 GHz to 22.5 GHz, respectively.

Computer Based Three Phase Power Analysing System (3상 전력을 기반으로 한 시스템 해석 컴퓨터)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.675-676
    • /
    • 2008
  • The computer based three phase power analysing system has been developed as a traveling standard for onsite power calibration. The system is utilized with digital-to-analog converts which were synchronized each other. Using digital signal processing technique the software has been developed to calculate power parameters. The calibration system is fully traceable to national standard system and, accuracy allows the calibration of industrial power measurement systems.

  • PDF

Study on TRX Channel Amplitude and Phase Calibration Method for a Radar Wind Profiler Based on 256 Active Phased Array (256 능동위상배열 기반 연직바람 관측장비의 송수신 채널 크기 및 위상 보정 방법 연구)

  • Jung, Woo-Jae;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.5
    • /
    • pp.162-170
    • /
    • 2022
  • In this paper, the phased-array transceiver (TRX) channel amplitude and phase calibration method for a radar wind profiler (RWP) based on the 256 active phased array is discussed. Without the additional module, the TX and RX calibration paths were secured using couplers and switches in the TRX front ends and the TRX switching duplexers, and the amplitude and phase of the 256 TRX were calibrated using a gain and phase detector. The beam widths and side lobes of five beams (vertical, east, west, south, and north) of the calibrated 256 active phased array antenna were confirmed by a near-field which agreed well with the simulation results. The proposed calibration method can be easily applied to a system based on an active phased array operated in an outdoor environment.

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.

Improved Calibration for the Analysis of Emerging Contaminants in Wastewater Using Ultra High Performance Liquid Chromatography and Time-of-Flight Mass Spectrometry

  • Pellinen, Jukka;Lepisto, Riikka-Juulia;Savolainen, Santeri
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.77-80
    • /
    • 2018
  • The focus of this paper is to present techniques to overcome certain difficulties in quantitative analysis with a time-of-flight mass spectrometer (TOF-MS). The method is based on conventional solid-phase extraction, followed by reversed-phase ultra high performance liquid chromatography of the extract, and mass spectrometric analysis. The target compounds included atenolol, atrazine, caffeine, carbamazepine, diclofenac, estrone, ibuprofen, naproxen, simazine, sucralose, sulfamethoxazole, and triclosan. The matrix effects caused by high concentrations of organic compounds in wastewater are especially significant in electrospray ionization mass spectroscopy. Internal-standard calibration with isotopically labeled standards corrects the results for many matrix effects, but some peculiarities were observed. The problems encountered in quantitation of carbamazepine and triclosan, due to nonlinear calibration were solved by changing the internal standard and using a narrower mass window. With simazine, the use of a quadratic calibration curve was the best solution.

Design of Calibration Circuit for LCOS Microdisplay (LCOS 마이크로디스플레이 구동용 보정회로 설계)

  • Lee, Youn-Sung;Wee, Jung-Wook;Han, Chung-Woo;Song, Nam-Chol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.469-471
    • /
    • 2022
  • This paper presents an implementation of a calibration circuit to correct the gain error, DC offset and sampling clock phase error generated in the process of converting digital pixels to analog pixels to drive an analog-driven 4K UHD LCOS panel. The proposed calibration circuit consists of a gain and DC offset adjustment circuit and a sampling clock phase adjustment circuit. The calibration circuit is implemented with an FPGA device, and video amplifiers.

  • PDF

A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image (노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법)

  • Kim, Kuk-Won;Kim, Min-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.909-916
    • /
    • 2009
  • This paper presents the automatic vision algorithm to generate and calibrate reference phase plane to improve the accuracy of 3D measuring machine of using phase shifting projection moire method, which is not traditional N-bucket method, but is based on direct image processing method to the pattern projection image. Generally, to acquire accurate reference phase plane, the calibration specimen with well treated surface is needed, and detailed calibration method should be performed. For the cost reduction of specimen manufacturing and the calibration time reduction, on the specimen, not specially designed, with general accuracy level, an efficient calibration procedure for the reference phase generation is proposed. The proposed vision algorithm is developed to extract the line center points of the projected line pattern from acquired images, derive the line feature information consisting of its slope and intercept by using sampled feature points, and finally generate the related reference phase between line pairs. Experimental results show that the proposed method make reference phase plane with a good accuracy under noisy environment and the proposed algorithm can reduce the total cost to make high accurate calibration specimen, also increase the accuracy of reference phase plane, and reduce the complex calibration procedure to move grid via N-bucket algorithm precisely.

A study on the phase calibration of the phase measuring profilometry (PMP 형상 측정법의 위상보정에 관한 연구)

  • 이연태;강영준;황용선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.421-424
    • /
    • 2002
  • The 3-D measurement using a sinusoidal grating pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. The PMP technique is discussed, and the analysis of the systematic errors, the calibration procedure designed to determined the optimal setting of the measurement parameters is illustrated. Results of measurements and calibrations on the measurement plane objects are described.

  • PDF