삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가 (Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement)

  • 이혁교;주지영;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.

전압변성기 비교기를 이용한 부담의 현장교정 기술 (On-Site Calibration Technology of Burden using Voltage Transformer Comparator)

  • 정재갑;권성원;박영태;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.503-507
    • /
    • 2005
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of VT burden used. Thus, precise measurement of burden is very important for the evaluation of VT. A method of evaluation for VT burden has been developed by employing the portable decade resistor, with AC-DC resistance difference less than 10-3. The burden value(value and power factor) can be obtained by conductance and susceptance, obtained by measuring the change of ratio error and phase angle error caused by the resistance change of decade resistor. The burden value and power factor obtained by the method are consistent with those obtained using power analyzer within corresponding uncertainties.

PS(Phase Shift)방법을 이용한 3차원 형상 측정에 대한 연구 (A study of Three Dimension Shape Measurement by PS(Phase-Shift))

  • 이혜인;김혜진;황보승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1784-1785
    • /
    • 2011
  • PS(Phase Shift) 방식을 이용하여 3차원 이미지 형상복원 시스템을 구현하였다. PS 방식은 위상을 이동시켜서 얻어진 강도를 arctan 시킴으로써 $-{\pi}{\sim}{\pi}$ 범위의 접혀진(wrapped) 위상을 얻을 수 있으며, 이러한 wrapped 위상을 위상 펼침(unwrapping) 알고리즘을 이용하여 불연속을 제거할 수 있다. 얻어진 위상 정보는 물체의 높이 정보에 비례하기 때문에 위상 분포로써 3차원 형상을 복원할 수 있다. Unwrapping 알고리즘에는 다양한 방식이 있지만 본 연구에서는 LabVIEW 프로그램을 이용하여 Goldstein 알고리즘을 구현하였으며, 감마(Gamma) 효과에 의한 노이즈를 줄이기 위하여 프로젝트와 카메라의 보정(calibration) 프로그램을 개발 및 적용하였다. 이와 같은 실험을 통하여 효과적으로 3차원 형상 정보를 얻을 수 있었다.

  • PDF

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

Determination of Grayanotoxin I and Grayanotoxin III in mad honey from Nepal using liquid chromatography-tandem mass spectrometry

  • Ahn, Su Youn;Kim, Suncheun;Cho, Hwangeui
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.82-91
    • /
    • 2022
  • Grayanotoxin-contaminated honey exhibits toxicity. In this study, a reliable and sensitive liquid-chromatography-tandem-mass-spectrometric method (LC-MS/MS) was developed and validated for the quantitation of grayanotoxin I and grayanotoxin III in honey. The grayanotoxins were extracted from honey via solid phase extraction and separated on a biphenyl column with a mobile phase consisting of 0.5 % acetic acid in water and methanol. Mass spectrometric detection was performed in the multiple-reaction monitoring mode with positive electrospray ionization. The calibration curve covered the range 0.25 to 100 ㎍/g. The intra- and inter-day deviations were less than 10.6 %, and the accuracy was between 94.3 and 114.0 %. The validated method was successfully applied to the determination of grayanotoxins in mad honey from Nepal. The concentrations of grayanotoxin I and grayanotoxin III in 33 out of 60 mad honey samples were 0.75 - 64.86 ㎍/g and 0.25 - 63.99 ㎍/g, respectively. The method established herein would help in preventing and confirming grayanotoxin poisoning.

저궤도 위성과 지상국간 접속 환경을 활용한 임무수행능력 지상 검증 시험 (Mission Operation Capability Verification Test for Low Earth Orbit(LEO) Satellite by Utilizing Interface Environment between LEO Satellite and Ground Station)

  • 이상록;구인회;임성빈
    • 항공우주기술
    • /
    • 제13권2호
    • /
    • pp.142-149
    • /
    • 2014
  • 저궤도위성은 발사 이후 초기 운영[1] 및 검보정 단계를 거쳐 정상 운영 단계로 진입한다. 정상 운영 단계에서는 이상 현상에 대한 대응조치[2], 궤도조정 작업 이외의 대부분 기간 동안 지상국으로부터 임무 명령을 수신하고 영상 촬영 및 전송 임무를 수행하게 된다. 저궤도위성과 지상국 시스템이 모두 관여된 임무수행능력은 저궤도위성 프로그램 성공 판단의 핵심 지표이고, 저궤도위성 프로그램 추진 목적과 일치하는 항목이기 때문에 지상 시험 단계에서 철저한 검증을 통해 신뢰성을 확보해야 한다. 지상 시험단계에서 지상국과 위성의 역할을 검증함으로써 임무수행능력에 대한 신뢰성을 확보하기 위해서는 저궤도위성의 실제 운용 상황과 유사한 시나리오를 작성하고 이를 바탕으로 명령을 생성하여 위성에 전달하며, 영상과 건강상태 텔레메트리(Telemetry) 데이터를 수신하는 등의 임무수행 전체 주기에 대한 검증이 필요하다. 이 논문은 저궤도위성과 지상국간 접속 환경을 활용해 수행된 임무수행능력 지상 검증 시험 설계 및 수행 결과에 대해 다룬다. 시험 설계시 고려되어야 할 항목과 이를 바탕으로 설계된 시험에 대해 상세히 서술하고 결과에 대해 정리하였다.

삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가 (Error analysis and performance test of the volumetric interferometer for three dimensional coordinate measurements)

  • 이혁교;주지영;김승우
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.521-529
    • /
    • 2002
  • 본 연구에서는 삼차원 공간상에서 절대 좌표를 측정하기 위한 부피 간섭계의 오차원인을 분석하고 각 오차원인이 최종 결과에 미치는 영향을 계산했다. 계산결과 광검출기 배열의 비선형성, 압전소자의 비선형성, 광섬유 내부의 온도변화 둥이 오차의 주요 원인임을 알 수 있다. 제안된 간섭계의 성능을 실험적으로 검증하기 위해 분해능 측정 및 이차원 광학식 스케일과의 비교를 수행했다. 또한 간섭계의 성능을 좀 더 엄밀하게 검증하기 위해 자가보정법을 적용해서 공간상에서 간섭계가 갖는 계통오차를 추출했으며 60mm$\times$60mm$\times$20mm공간에서 최대오차 1 $\mu\textrm{m}$ 이하를 얻었다.

Korea Pathfinder Lunar Orbiter Magnetometer Instrument and Initial Data Processing

  • Wooin Jo;Ho Jin;Hyeonhu Park;Yunho Jang;Seongwhan Lee;Khan-Hyuk Kim;Ian Garrick-Bethell;Jehyuck Shin;Seul-Min Baek;Junhyun Lee;Derac Son;Eunhyeuk Kim
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권4호
    • /
    • pp.199-215
    • /
    • 2023
  • The Korea Pathfinder Lunar Orbiter (KPLO), the first South Korea lunar exploration probe, successfully arrived at the Moon on December, 2022 (UTC), following a 4.5-month ballistic lunar transfer (BLT) trajectory. Since the launch (4 August, 2022), the KPLO magnetometer (KMAG) has carried out various observations during the trans-lunar cruise phase and a 100 km altitude lunar polar orbit. KMAG consists of three fluxgate magnetometers capable of measuring magnetic fields within a ± 1,000 nT range with a resolution of 0.2 nT. The sampling rate is 10 Hz. During the originally planned lifetime of one year, KMAG has been operating successfully while performing observations of lunar crustal magnetic fields, magnetic fields induced in the lunar interior, and various solar wind events. The calibration and offset processes were performed during the TLC phase. In addition, reliabilities of the KMAG lunar magnetic field observations have been verified by comparing them with the surface vector mapping (SVM) data. If the KPLO's mission orbit during the extended mission phase is close enough to the lunar surface, KMAG will contribute to updating the lunar surface magnetic field map and will provide insights into the lunar interior structure and lunar space environment.

다목적 PSO 알고리즘을 활용한 SWAT의 자동보정 적용성 평가 (Evaluation of multi-objective PSO algorithm for SWAT auto-calibration)

  • 장원진;이용관;김성준
    • 한국수자원학회논문집
    • /
    • 제51권9호
    • /
    • pp.803-812
    • /
    • 2018
  • 본 연구는 다목적함수를 고려한 입자군집최적화(Particle Swarm Optimization, PSO) 알고리즘을 Python으로 개발하고, Soil and Water Assessment Tool (SWAT) 모형에 적용하여 자동보정 알고리즘의 적용 가능성을 평가하였다. SWAT 모형의 유출 해석은 안성천의 공도 수위 관측소 상류유역($364.8km^2$)을 대상으로 하였으며, 공도 지점의 2000년부터 2015년까지의 일 유량 자료를 이용하였다. PSO 자동보정은 결정계수(coefficient of determination, $R^2$), 평균제곱근오차(RMSE), NSE 모형효율계수(Nash-Sutcliffe Efficiency, $NSE_Q$), 특히 중간유출과 기저유출의 보정을 위해 $NSE_{INQ}$ (Inverse Q)를 활용하여 SWAT을 보정하였다. PSO을 통한 SWAT 모형의 자동보정과 수동보정의 유출해석 결과, 각각 $R^2$는 0.64, 0.55, RMSE는 0.59, 0.58, $NSE_Q$는 0.78, 0.75, $NSE_{INQ}$는 0.45, 0.09의 상관성 분석결과를 보였다. PSO 자동보정 알고리즘은 수동보정에 비하여 높은 향상을 보였는데 특히 유출의 감수곡선을 개선시켰으며 적절한 매개변수 추가(RCHRG_DP)와 매개변수 범위의 설정으로 수동보정의 한계를 보완하였다.