• Title/Summary/Keyword: phase angle detection

Search Result 86, Processing Time 0.026 seconds

Source Localization Technique for Radar Pulse Emission by Using Scanning Method of Interest Area (관심영역 스캐닝기법을 이용한 레이더 펄스 발생원 위치 추정기법)

  • Choi, Kyong-Sik;Kim, Jong-Pil;Won, Hyeon-Kwon;Park, Jae-Hyun;Kim, In-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.9
    • /
    • pp.889-895
    • /
    • 2011
  • In recent days, some techniques to prevent from radar detection have been applied on aircraft system. RWR(Radar Warning Receiver) can be used for estimating the source location of the aircraft which emits radar pulse. Current existing method of localizing radar pulse emission source is using AOA(Angle Of Arrival) and most techniques are focused on finding exact AOA to find exact location. In this case, however, the exact AOA does not always result in finding exact source location while target aircraft is moving fast. In this paper, a localization method using the phase delay of the radar pulse's low frequency applies and so a scanning method for the interest area does in order to estimate exact source location by using phase delay.

Evaluation of Coronary Artery Disease with Gated Blood Pool Scan Using Dipyridamole (Dipyridamole 부하 심장 풀 스캔을 이용한 관동맥질환의 평가)

  • Kim, Gwang-Weon;Choi, Chung-Il;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Chae, Shung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Park, Hee-Myung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.27-36
    • /
    • 1991
  • Thirty-one patients with coronary artery disease and twenty-sir normal subjects underwent $^{99m}Tc-GBPS$ before and after coronary vasodilatation was induced by dipyridamle 0.54 mg/kg given IV over 4 min. LVEF, ${\Delta}EF$ and regional wall motion by phase analysis were measured during rest and dipyridamole infusion. The results were as follows: 1) Mean LVEF of normal subjects was significantly higher than that of MI group (p=0.001), but similar to that of angina group during rest. Among MI group, mean LVEF of anterior MI group was significantly lower than that of inferior MI group during rest (p=0.024). 2) The normal subjects had a significaat increase in mean LVEF during dipyridamole infusion $(+12{\pm}3.8)$, while the CAD group had no increase $(+2{\pm}5.0)$ (p<0.001). If an increase of LVEF during stress is less than 5%, it suggests an abnormality. The sensitivity and specificity of LVEF changes after dipyridamole infusion were 81%, 96%, respectively. 3) With phase analysis, LV mean phase angle of normal subjects and CAD patients was $143{\pm}20.5^{\circ},\;132{\pm}20.6^{\circ}$ respectively, durign rest (p=0.049). But an ncrease of LV mean phase angle during dipyridamole infusion in these two groups was not significantly different. Dipyridamole infusion did not affect standard deviation and FWHM of phase angle. 4) Regional wall motion was abnormal in 5 patients (16%) during dipyridamole infusion. 5) Side effects with dipyridamole infusion include; headache, angina pain, chest discomfirt, nausea, weakness sense. In conclusion, dipyridamole GBPS might be useful in detection and follow up of CAD.

  • PDF

A Technology of Microwave Direction Finding with Circular Array Combination Method (원형 배열 복합 방식을 이용한 초고주파 방향 탐지 기술)

  • Lim Joong-Soo;Jung Chul-Gu;Chae Gyoo-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.549-555
    • /
    • 2005
  • This paper describes a microwave direction finding technology which is used for RF signal acquisition and monitoring systems. This paper suggests a direction finding method which use a combination of the amplitude-comparison technology and the phase-comparison technology. The amplitude-comparison technology uses the amplitude difference of the RF signals received from the array antennas of direction finding system and removes the ambiguity of wave incident bearing. The phase-comparison technology uses the phase difference of the RF signals received from the same nay antennas and makes a good direction finding accuracy. The suggested direction finding technology is designed to place 8 array antennas in a $45^{\circ}$ distance around the circle for $360^{\circ}$ azimuth angle. Also it is designed to use the phase difference of the received signals ken two nearby antennas to measure the signal incident direction accurately and to use the amplitude difference to remove the ambiguity of wave incident bearing. The simulation and measurement results are under $0.5^{\circ}$ bearing error in $2.0\~6.0$ GHz when SNR is 30 dB.

Ultrasonic guided waves-based fatigue crack detection in a steel I-beam: an experimental study

  • Jiaqi Tu;Xian Xu;Chung Bang Yun;Yuanfeng Duan
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.13-27
    • /
    • 2023
  • Fatigue crack is a fatal problem for steel structures. Early detection and maintenance can help extend the service life and prevent hazards. This paper presents the ultrasonic guided waves-based (UGWs-based) fatigue crack detection of a steel I-beam. The semi-analytical finite element model has been built to obtain the wave propagation characteristics. Damage indices in both time and frequency domains were analyzed by considering the characteristic variations of UGWs including the amplitude, phase angle, and wave packet energy. The pulse-echo and pitch-catch methods were combined in the detection scheme. Lab-scale experiments were conducted on welded steel I-beams to verify the proposed method. Results show that the damage indices based on the characteristic variations in the time domain can identify and localize the fatigue crack before it enters the rapid growth stage. The damage severity can be reasonably evaluated by analyzing the time-domain damage indices. Two nonlinear damage indices in the frequency domain give earlier warnings of the fatigue crack than the time-domain damage indices do. The identification results based on the above two nonlinear indices are found to be less consistent under various excitation frequencies. More robust nonlinear techniques needed to be searched and tested for early crack detection in steel I-beams in further study.

Development and Experiment of a Linear Array Acoustic Lens with 31 Microphones (마이크로폰 31개로 이루어진 선형배열 음향렌즈의 구성과 실험)

  • Hyun, Seok-Bong;Min, Dong-Hyun;Kim, Su-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.15-23
    • /
    • 1994
  • We developed an electronic lens for acoustic imaging systems, which is linear array with 31 microphones equally spaced with distance 34mm. Resonant frequency fo receiver circuit coupled to microphone is 20 kHz. We arranged 16 microphones horizontally and 15 microphones vertically, so that the array allows us to obtain a 2 dimensional angle of source, and to track the motion of source in real time. Due to the problem of aliasing in discrete Fourier Transfrom, the maximum observable angle of the lens is limited to 15${\circ}$. We also employed quadrature phase detection scheme to adjust the focus. We have tested the acoustic lens with a personal computer in an anechoic room and obtained the results agreed with the acoustic imaging theory.

  • PDF

Gait Phases Detection and Judgment based Multi Biomedical Signals (다중 생체 신호 기반 보행 단계 감지 및 판단)

  • Kim, S.J.;Jeong, E.C.;Song, Y.R.;Yoon, K.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.43-48
    • /
    • 2012
  • In this paper, we present the method of gait phases detection using multi biomedical signals during normal gait. Electromyogram(EMG) signals, muscle of thigh angle measurement device and resistive sensors are used for experiments. We implemented a test targeting five adult male and identified the pattern of EMG signal of normal gait. For acquiring the EMG signal, subjects attached surface Ag/AgCl electrodes to quadriceps femoris, biceps femoris, tibialis anterior and gastrocnemius medialis. Resistance sensors are attached to the heel toe and soles of the each feet for measuring attachment state of between feet and ground. Infrared sensors are attached on the thigh and thigh angle measurement device has the range from flection 25 degrees to extension 20 degrees. The results of this paper, The stance and swing phase could be confirmed during the normal gait and be classified in detail the eight steps.

  • PDF

Quantitative evaluation of through-thickness rectangular notch in metal plates based on lamb waves

  • Zhao, Na;Wu, Bin;Liu, Xiucheng;Ding, Keqin;Hu, Yanan;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.71 no.6
    • /
    • pp.751-761
    • /
    • 2019
  • Lamb wave technology is a promising technology in the field of structural health monitoring and can be applied in the detection and monitoring of defects in plate structures. Based on the reconstruction algorithm for the probabilistic inspection of damage (RAPID), a Lamb-based detection and evaluation method of through-thickness rectangular notches in metal plates was proposed in this study. The influences of through-thickness rectangular notch length and the angle between sensing path and notch length direction on signals were further explored through simulations and experiments. Then a damage index calculation method which focuses on both phase and amplitude difference between detected signals and baseline signals was proposed. Based on the damage index difference between two vertically crossed sensing paths which pass through the notch in a sensor network, the notch direction identification method was proposed. In addition, the notch length was determined based on the damage index distribution along sensing paths. The experimental results showed that the image reconstructed with the proposed method could reflect the information for the evaluation of notches.

Analysis of Lower-Limb Motion during Walking on Various Types of Terrain in Daily Life

  • Kim, Myeongkyu;Lee, Donghun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.319-341
    • /
    • 2016
  • Objective:This research analyzed the lower-limb motion in kinetic and kinematic way while walking on various terrains to develop Foot-Ground Contact Detection (FGCD) algorithm using the Inertial Measurement Unit (IMU). Background: To estimate the location of human in GPS-denied environments, it is well known that the lower-limb kinematics based on IMU sensors, and pressure insoles are very useful. IMU is mainly used to solve the lower-limb kinematics, and pressure insole are mainly used to detect the foot-ground contacts in stance phase. However, the use of multiple sensors are not desirable in most cases. Therefore, only IMU based FGCD can be an efficient method. Method: Orientation and acceleration of lower-limb of 10 participants were measured using IMU while walking on flat ground, ascending and descending slope and stairs. And the inertial information showing significant changes at the Heel strike (HS), Full contact (FC), Heel off (HO) and Toe off (TO) was analyzed. Results: The results confirm that pitch angle, rate of pitch angle of foot and shank, and acceleration in x, z directions of the foot are useful in detecting the four different contacts in five different walking terrain. Conclusion: IMU based FGCD Algorithm considering all walking terrain possible in daily life was successfully developed based on all IMU output signals showing significant changes at the four steps of stance phase. Application: The information of the contact between foot and ground can be used for solving lower-limb kinematics to estimating an individual's location and walking speed.

Measurement of magnetic kerr rotation and faraday fotation angles by polarization modulation method (편광 변조 방법에 의한 자기 Kerr 회전각 및 Faraday 회전각 측정)

  • 이용호;이상수;이용호
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.105-110
    • /
    • 1992
  • In order to measure fine rotation angles by magneto-optic effects of magneto-optical recording thin films, a polarization modulation method is used. In the experiment, the polarization of laser (He-Ne laser) beam is modulated by a Faraday rotator and the amplified modulated signals are selectively detected by phase sensitive detector. The magnetic Kerr rotation and Faraday rotation hysteresis loops are investigated by this method for thermally evaporated amorphous TbFeCo thin films and RF sputtered garnet thin films. Rotation angles about $0.25^{\circ}$ are measured easily from TaFeCo thin films. In the case of longitudinal Kerr rotation, very small rotation angle of $2.5\times10^{-3^\circ}$ is measured with good accuracy of the measurement (about $1\times10^{-3^\circ}$). And it is found that each thin films have the hysteresis curves of high coercivity and good squareness.

  • PDF

The Detection of the Lane Curve using the Lane Model on the Image Coordinate Systems (이미지 좌표계상의 차선 모델을 이용한 차선 휨 검출)

  • 박종웅;이준웅;장경영;정지화;고광철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.193-200
    • /
    • 2003
  • This paper proposes a novel algorithm to recognize the curve of a structured road. The proposed algorithm uses an LCF (Lane Curve Function) obtained by the transformation of a parabolic function defined on world coordinate into image coordinate. Unlike other existing methods, the algorithm needs no transformation between world coordinate and image coordinate owing to the LCF. In order to search for an LCF describing the lane best, the differential comparison between the slope of an assumed LCF and the phase angle of edge pixels in the LROI (Lane Region Of Interest) constructed by the LCF is implemented. As finding the true LCF, the lane curve is determined. The proposed method is proved to be efficient through various kinds of images, providing the reliable curve direction and the valid curvature compared to the real road.