• Title/Summary/Keyword: phase analysis

Search Result 11,773, Processing Time 0.04 seconds

Simulation of Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL (3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 시뮬레이션)

  • Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.167-168
    • /
    • 2005
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-Tc superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

Performance Analysis of digital phase shifter using Hilbert transform (힐버트 변환을 이용한 디지털 위상천이기의 성능 분석)

  • Seo, Sang Gyu;Jeong, Bong-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.39-44
    • /
    • 2013
  • In this paper digital phase-shifter for multi-arm spiral antennas was designed by using Hilbert transform. All frequency components in input signal are phase-shifted for 90 degree by Hilbert transform, and the transform is implemented by FIT and IFIT. Digital phase-shifter generates two signals with phase difference of 90 degree by using Hilbert transform from input signals sampled by analog-digital converter(ADC), and then the input signal is phase-shifted for a given phase by using two signals. Hilbert transform based on digital phase-shifter is designed by Xilinx System generator, and the effects of input noise, FIT point, sampling period, initial phase of input signal, and shifted phase are simulated and its results are compared with Matlab results.

Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL (3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성)

  • Lim, Sung-Hun;Han, Tae-Hee;Park, Hyoung-Min;Cho, Yong-Sun;Song, Jae-Joo;Choi, Myoung-Ho;Hwang, Jong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.112-113
    • /
    • 2006
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-$T_c$ superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

A Note on Complex Two-Phase Sampling with Different Sampling Units of Each Phase

  • Lee, Sang Eun;Jin, Young;Shin, Key-Il
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.5
    • /
    • pp.435-443
    • /
    • 2015
  • Two phase sampling design is useful to increase estimation efficiency using deep stratification, improved non-response adjustment and reduced coverage bias. The same sampling units are commonly used for the first and the second phases in complex two-phase sampling design. In this paper we consider a sampling scheme where the first phase sampling units are clusters and the second phase sampling units are list samples. Using selected clusters in first phase requires that we list up elements in the selected clusters from the first phase and then use the list as a secondary sampling frame for the second phase sampling design. Then we select second phase samples from the listed sampling frame. We suggest an estimator based on the complex two-phase sampling design with different sampling units of each phase. Also the estimated variances of the estimator obtained by using classic and replication variance methods are considered and compared using simulation studies. For real data analysis, 2010 Korea Farm Household Economy Survey (KFHES) and 2011 Korea Agriculture Survey (KAS) are used.

A Study on the Structure Properties of Amorphous $As_{40}Se_{50-x}S_{x}Ge_{10}$ Thin Film (비정질 $As_{40}Se_{50-x}S_{x}Ge_{10}$ 박막의 구조특성에 관한 연구)

  • 김종빈;정홍배
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.106-112
    • /
    • 1992
  • In this paper, we analyze the structure characteristics of $As_{40}Se_{50-x}S_{x}Ge_{10}$ system bulk and thin films. As the results of XRD patterns, it identified amorphous state. In order to find the glass transition temperature($T_g$), crystallization($T_c$) and melting point ($T_m$)of bulk sample, it ascertained that TS1gT is 238$^{\circ}C$ in $As_{40}Se_{15}S_{35}Ge_{10}$, and 231$^{\circ}C$ in $As_{40}Se_{25}S_{25}Ge_{10}$ & $As_{40}Se_{50}Ge_{10}$ following the thernal analysis by DSC, DTA, & TGA method. Also it was confirmed the phase seperation of continuous phase and dispertion phase by the optical texture of polarizing microscope and $T_g$ near 20$0^{\circ}C$ in thin film. Therefore, it was found that it occurs the phase seperation of Ge-rich dontinuous phase and Se-rich dispersion phase following the EDS analysis of thin film and the surface SEM photograph.

  • PDF

Experimental Analysis of the Effect of Phase Change at the Entrance of a Capillary Tube by Sub-cooling Control on Refrigerant-induced Noise (과냉도에 따른 모세관 입구단에서의 냉매 상태 변화가 냉장고 냉매 소음에 미치는 영향의 실험적 분석)

  • Oh, Young-Hoo;Kim, Min-Seong;Han, Hyung-Suk;Kim, Tae-Hoon;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1184-1190
    • /
    • 2012
  • This study is focused on the experimental analysis of the noise induced by phase change of refrigerant at the entrance of capillary tube. The refrigerant is usually two-phase condition when it flowed into the capillary tube. At the entrance of capillary tube, the phase condition of refrigerant is formed by sub-cool control. If it has sufficient sub-cool temperature, all of the vapor refrigerants turned to liquid, which means there is only liquid. Otherwise, the gas is coexisted. Based on this theory, we experiment on each case by changing sub-cool temperature using refrigerant-supplying equipment. The noise level is measured for each case and compared.

Free Vibration Analysis of Two Identical Rectangular Plates Coupled with Fluid (유체로 연성된 동일한 두 직사각 평판의 고유진동 해석)

  • Jeong, Kyeong-Hoon;Lee, Seong-Cheol;Yoo, Gye-Hyoung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.8-15
    • /
    • 2002
  • In order to investigate the vibration characteristics of fluid-structure interaction problem, we modeled two identical rectangular plates coupled with fluid. A commercial computer code, ANSYS was used to perform finite element analysis and FEM solutions were compared with the experimental results to verify the finite element model. As a result, comparison of FEM and experiment showed good agreement, and the transverse vibration modes, in-phase and out-of-Phase, were observed alternately in the fluid-coupled system. The effect of fluid gap size on the fluid-coupled natural frequency were investigated. It was shown that the mode numbers increased, the normalized natural frequencies monotonically increased. And it was also found that an increase of the fluid gap reduced the coupled natural frequencies for the in-phase modes but increased the coupled natural frequencies for the out-of phase modes, and eventually converged to the results of an infinite fluid gap.

Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition (여러 환경조건에 대한 고분자애자의 누설전류 특성 변화)

  • Park Jae-Jun;Choi In-Hyuk;Lee Dong-il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

A Study on the Hot Cracking Phenomena of Cu-Ni Bearing Hot Rolled Steels (Cu-Ni 첨가형 열연강판의 열간균열현상에 관한 연구)

  • Yun, In-Taek;Jo, Yeol-Rae;Kim, Sun-Ho;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.335-340
    • /
    • 1999
  • The hot cracking phenomena and phase behaviors during hot working process of Cu-Ni bearing hot rolled steels were investigated by a $90^{\circ}$bending tests, BSE image analysis and EDS analysis. For aNi-free 1.2% Cu bearing steel, the surface hot cracking occurred about $1100^{\circ}C$ due to a liquid state Cu-enriched phase formed continuously at the interface between oxide scale and matrix. The liquid Cu-enriched phase penetrated into austenite grain boundaries and caused surface cracking during the hot working. In case of 0.6% Ni containing 1.2% Cu-Ni bearing steel, solid state Cu-Ni-riched phase existed at the scale/matrix interface as a discontinuous type. But the higher addition of 1.2% Ni, solid state Ni-Cu-riched phase was formed dominantly in the oxide scale. It was found that the addition of Ni suppressed the surface cracking of 1.2% Cu bearing steel by eliminating the liquid state Cu-enriched phase.

  • PDF

The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia

  • Caglar, Ipek;Ates, Sabit Melih;Duymus, Zeynep Yesil
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.132-137
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS. 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS. All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION. Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.