• Title/Summary/Keyword: phase II system

Search Result 327, Processing Time 0.031 seconds

A Tuning Method for the Power System Stabilizer of a Large Thermal Power Plant and Its Application to Real Power System : PART II - Field Tests and Verification of PSS Performance (대형 화력발전기 전력계통 안정화장치(IEEEST-PSS)의 정수선정 기법과 실계통 적용: PART II - PSS 현장 성능시험 절차 및 성능검증)

  • Shin, Jeong-Hoon;Nam, Su-Chul;Baek, Seung-Mook;Song, Ji-Young;Lee, Jae-Gul;Kim, Tae-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.114-121
    • /
    • 2011
  • This paper, as the second part of the paper, dealt with the field test and test results to validate PSS(Power System Stabilizer) parameters which are previously tuned in Part 1 paper. In Part 1 of the paper, the selection of parameters such as lead-lag time constants for phase compensation and system gain was optimized by using linear & eigenvalue analyses and they were verified through the time-domain transient stability analysis. In part 2, the performance of PSS was finally verified by the generator's on-line field test. Through the comparisons of simulation results and measured data before and after tuning of the PSS, the models of generator and its controllers including AVR, Governor and PSS used in the simulation are verified and confirmed.

A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China- (인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로-)

  • Back, Seong-Kyung;Lee, Seung-Hoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

A Study of Flow Characteristics by Acoustic Excitation on the Laminar Non-premixed Jet Flame (층류 비예혼합 분류화염에서 음향가진에 의한 유동특성 연구)

  • Oh, Kwang-Chul;Lee, Kee-Man
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.160-168
    • /
    • 2010
  • An experimental study has been conducted to investigate the effects of forcing amplitude on the tone-excited non-premixed jet flame of the resonance frequency. Visualization techniques are employed using the laser optic systems, which are RMS tomography, PLIF and PIV system. There are three lift-off histories according to the fuel flow rates and forcing amplitudes; the regime I always has the flame base feature like turbulent flame when the flame lift-off, while the flame easily lift-off in the regime II even if a slight forcing amplitude applied. The other is a transient regime and occurs between the regime I and regime II, which has the flame base like the bunsen flame of partial premixed flame. In the regime I and II, the characteristics of the mixing and velocity profile according to the forcing phase were investigated by the acetone PLIF, PIV system. Particular understanding is focused on the distinction of lift-off history in the regime I and II.

Phases and Phase Relations of the System Pd-Sb (팔래듐-안티모니계의 화합물 및 상평형 연구)

  • 김원사
    • Journal of the Mineralogical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.13-22
    • /
    • 1995
  • Phase relations of the Pd-Sb system were investigated using the sealed-capsule technique; the quenched run products were studied by reflected light microscopy, X-ray diffraction, and electron microprobe analysis. Eight binary phases were confirmed to exist in the system: Pd20Sb7, Pd31Sb12, Pd8Sb3 (mertieite II), Pd5Sb2, Pd2Sb, Pd5Sb3, PdSb (sudburyite), and PdSb2, (unnamed PdSb2), The X-ray powder diffraction data of all the phases, except for Pd5Sb3, however, may be indexable on an orthorhombic cell, space group Cmc2, with a=3.362(1), b=17.484(7), c=6.934(2)$\AA$. Some physical properties as well as re-determined cell parameters are newly established. A revised phase relations of the Pd-Sb system are presented.

  • PDF

Analysis and design of a FSK Demodulator with Digital Phase Locked Loop (디지털 위상고정루프를 이용한 ESK복조기의 설계 및 성능 분석)

  • 김성철;송인근
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-200
    • /
    • 2003
  • In this paper, FSK(Frequency Shift Keying) demodulator which is widely used for FH-SS system is designed and the experimental results are analyzed. The performance of the ADPLL(All-digital Phase-Locked-Loop), which is the main part of the demodulator circuit, is analyzed by the computer program. Using Maxplus-II tool provided by altera. co., ltd, each part of the ADPLL is designed and all of them is integrated into EPM7064SLC44-10 chip. And the simulation results are compared with the characteristics of the implemented circuits for analysis. There is about 2${\mu}\textrm{s}$ difference in time constant of the PLL. This difference is not critical in the demodulator. And the experimental results show that the transmitted data is well demodulated when the phase difference between the FSK modulated signal and the reference signal is about 180 degree.

Metabolic Responses of Activated Sludge to Pentachlorophenol in a SBR System (SBR 처리 장치에서 활성 슬럿지의 대사에 미치는 Pentachlorophenol의 독성 효과)

  • KIM Sung-Jae;Benefield Larry D.
    • Journal of Aquaculture
    • /
    • v.6 no.4
    • /
    • pp.323-338
    • /
    • 1993
  • The primary objective of this study was to examine the toxic effects of PCP on activated sludge and to analyze its metabolic responses while treating wastewater containing pentachlorophenol (PCP) in a sequencing batch reactor (SBR) system operating under different control strategies. This study was conducted in two phases 1 and 2 (8-hr and 12-hr cycles). Each phase was operated with two control strategies I and II. Strategy I (reactor 1) involved rapid addition (5 minutes to complete) of substrate to the reactor with continuous mixing but no aeration for 2 hours. Strategy II (reactor 2) involved adding the feed continuously during the first 2 hours of the cycle when the system was mixed but not aerated. During both phases each reactor was operated at a sludge age of 15 days. The synthetic wastewater was used as a feed. The COD of the feed solution was about 380 mg/L. After the reference response for both reactors was established, the steady state response of each system was established for PCP feed concentrations of 0.1 mg/L, 1.0 mg/L, and 5.0 mg/L in SBR systems operating on both 8-hr and 12-hr cycles. Soluble COD removal was not inhibited at any feed PCP concentrations used. At 5.0 mg/L feed PCP concentration and in SBR systems operating on phase 2, the concentrations or ML VSS were decreased; selective pressure on the mixed biomass might be increased, narrowing the range of possible ecological responses; the settleability of activated sludge was poor; the SOURs were increased, showing that the systems were shocked. Nitrification was made to some extent at all concentrations of feed PCP in SBR systems operating on phase 2 whereas in SBR systems operating on phase 1 little nitrification was observed. Then, nitrification will be delayed as much as soluble COD removal is retarded due to PCP inhibition effects. Enhanced biological phosphorus removal occurring in the system operating with control strategy I during phase 1 of this work and in the presence of low concentrations of PCP was unreliable and might cease at anytime, whereas enhanced biological phosphorus removal occurring in the system operating with either control strategy I or II during phase 2 of this work and in the presence of feed PCP concentrations up to 1.0 mg/L was reliable. When, however, such processes were exposed to 5.0 mg/L PCP dose, enhanced phosphorus removal ceased and never returned.

  • PDF

Viability test and bulk harvest of natural zooplankton communities to verify the efficacy of a ship's ballast water treatment system based on USCG phase-II (USCG phase-II 선박평형수 처리장치 성능 평가를 위한 자연 해수의 동물플랑크톤 대량 확보 및 생사판별)

  • Jang, Min-Chul;Baek, Seung Ho;Shin, Kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • We investigated >$50-{\mu}m$ marine planktonic organisms (mainly zooplankton) using a bongo net in Masan Bay and Jangmok Bay in order to harvest 75% of natural communities based on Phase-II approval regulations by the United States Coast Guard (USCG). The concentrated volume (in 1 ton) and abundance of zooplankton were $1.8{\times}10^7ind.ton^{-1}$ and $2.3{\times}10^7ind.ton^{-1}$, and their survival rates were 82.6% and 80.1%, respectively. The community structure in Jangmok Bay was similar to that in Masan Bay, and dominant species were adult and immature groups (stage IV) of genus Acartia. Harvested populations were inoculated in a 500-ton test tank. Although the population abundances were $6.0{\times}10^4ind.ton^{-1}$ for both bay samples, the mortality rates were higher in the Masan Bay population (32%) than the Jangmok Bay population (20%). We considered the reason to be that there were 30% more immature individuals of Acartia from Masan Bay than from Jangmok Bay. The younger population may have been greatly stressed by the moving process and netting gear. After applying a Ballast Water Treatment System (BWTS) using a sample form Jangmok Bay, the mortality rates in the treatment groups were found to be 100% after 0 days and 5 days, implying that the BWTS worked well. During the winter season, the zooplankton concentration method alone did not easily satisfy the approval standards of USCG Phase II (> $10{\times}10^4ind.ton^{-1}$ in the 500 ton tank). Increasing the netting frequency and additional fishing boats may be helpful in meeting the USCG Phase II biological criteria.

Development of a Joint University Campus as a Key Element in the Regional Innovation System in Sejong Tech Valley, South Korea

  • Lee, Seo-Jeong;Lee, Eung-Hyun;Oh, Deog-Seong
    • World Technopolis Review
    • /
    • v.6 no.2
    • /
    • pp.148-158
    • /
    • 2017
  • Sejong City, which has been chosen as a new administrative capital of South Korea, has completed the first phase of its development plan with the construction of the facilities needed to accommodate central administrative organizations and the required accompanying population. Now, it is undergoing the second phase of development with a focus on strengthening the region's innovation capacity to catalyze endogenous development. The strategy for phase II is to establish a regional innovation system including building necessary infrastructure and attracting innovation agents such as universities, businesses, and research institutes. The first step for this is developing a research complex, tentatively named Tech Valley, that includes universities, research institutes, and businesses, and building infrastructure comprising a science complex, a knowledge industry center, and support facilities. Phase II of the city's development initiative includes the establishment of a joint university campus, which is to serve as a center to promote cooperation among industry actors, universities, and research institutes. The concept of a joint campus has been drawn from a need to enhance capacity for innovation and specialization in the region's industries and to maximize synergy among participating universities through the sharing of research equipment, facilities, and programs. The joint campus is expected to play a key role in creating an innovation system in the region by enhancing research capacity for strategic industries, cultivating highly skilled human resources, and leading industry-academia-research cooperation. In order to ensure the sustainable development of the new city, there is a growing need to have a main player in place that could lead the region's economic development. The joint campus will propel industrial specialization and serve as a catalyst to attract competent universities to the region. This paper will examine the concept, major functions, and the establishment and operation of the joint campus.

The Effect of DME on Phase Equilibria of Methane Hydrates (DME가 메탄하이드레이트 상평형에 미치는 영향)

  • Lim, Gyegyu;Lee, Gwanghee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.660-669
    • /
    • 2012
  • Gas resources captured in the form of gas hydrates are an order of magnitude larger than the resources available from conventional resources. Focus of this research is to investigate the effect of DME on phase equilibria of methane hydrate, as well as the possibility of the use of the PRO/II computer simulation to estimate the phase equilibria. In systems containing water and a gaseous component like, for instance, methane, ethane, and propane, gas hydrates may occur, if conditions in terms of pressure and temperature are satisfied. Mixtures of gases, e.g. LPG or natural gas, are also able to form gas hydrates in the presence of water. The experiments presented here were performed at temperatures varying between 268.15K and 288.15K and at pressures varying between 1.88 MPa and 10.56 MPa. It was found that the phase equilibria of methane hydrate is influenced by the addition of DME to the system. The pressure for the equilibrium hydrate-liquid water-vapor (H - $L_w$ - V) in the system water + methane is reduced upon addition of DME. The phase equilibria of methane hydrate can be estimated by the PRO/II computer simulation, whereas those of methane hydrate containing DME or LPG can't be estimated properly.

Phase-Shifter for Real-Time Control of Transmission System (송전계통의 실시간 제어를 위한 위상변이기)

  • Han, Hyung-Moon;Chang, Byong-Kun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.432-434
    • /
    • 1994
  • This paper describes a phase-shifter which can flexibly adjust the active and reactive power flow through an ac transmission line. The phase-shifter has two voltage-source converters sharing an energy storage capacitor. The magnitude of the injected voltage is controlled by the converter I connected in parallel with the sending terminal, while that of phase angle by the converter II in series with the line through the coupling transformer. In order to analyze the whole system operation, an equivalent circuit model was developed and verified by a computer simulation with EMTP code.

  • PDF