• Title/Summary/Keyword: phase Doppler method

Search Result 99, Processing Time 0.026 seconds

GNSS Precise Positioning Design for Intelligent Transportation System (지능형 교통시스템에 적합한 위성항법 기반의 정밀측위 구조 설계)

  • Lee, Byung-Hyun;Im, Sung-Hyuck;Heo, Moon-Beom;Jee, Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.1034-1039
    • /
    • 2012
  • In this paper, a structure of precise positioning based on satellite navigation system is proposed. The proposed system is consisted with three parts, range domain filter, navigation filter and position domain filter. The range domain filter generates carrier phase-smoothed-Doppler and Doppler-smoothed-code measurements. And the navigation filter calculates position and velocity using double-differenced code/carrier phase/Doppler measurements. Finally, position domain filter smooth position error, and it means enhancement of positioning performance. The proposed positioning method is evaluated by trajectory analysis using precise map date. As a result, the position error occurred by multipath or cycle slip was reduced and the calculated trajectory was in true lane.

A Study on Improvement of Doppler Frequency Estimation Method in a Weather Radar (기상 레이다에서의 도플러 주파수 추정 방법 개선에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.1999-2005
    • /
    • 2015
  • A wind velocity is measured in a weather radar as well as the strength of return echoes from rain clouds. These wind velocities are obtained through estimation of Doppler frequencies in return signals. This kind of Doppler frequency estimation method is called as a correlation method. It is widely used in most weather radars because of less computation time. However, it may cause serious errors if a spectrum is not symmetric. Therefore, in this paper, it is shown that the improved method using 3rd order phase estimation model yields the more accurate estimation of the average Doppler frequency using various simulated weather data.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

A study on the development of Pulsed Doppler System using Auto-Correlation (Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구)

  • Lim, Chun-Sung;Rang, Chung-Shin;Lee, Hang-Sei;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF

A study on the development of CW(Continuous-Wave) Doppler System using FFT (FFT를 이용한 연속초음파 도플러 장치에 관한 연구)

  • Lee, Dae-Hyung;Kang, Chung-Shin;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

Measurement of Mode Shape By Using A Scanning Laser Doppler Vibrometer (스캐닝 레이저 도플러 진동계를 이용한 모드 해석)

  • Gang, Min-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2560-2567
    • /
    • 2000
  • When spatially dense velocity distribution is measured by a scanning laser Doppler vibrometer, the Fourier transform method provides the real and imaginary parts of the mode shapes in the form of a polynomial. However the Fourier transform method is often impractical because the independent decomposition property of cosine and sine components into real and imaginary parts, respectively, does not hold due to the leakage problem which commonly occurs in the Fourier transform of harmonic signals. To deal with this problem, a Hilbert transform method is newly proposed in this article. The proposed method is free from the leakage problem and relatively robust to the scanning error. A simulation example is provided to verify the effectiveness of this method.

Measurement of Mode Shape By Using A Scanning Laser Doppler Vibrometer (스캐닝 레이저 도플러 진동 측정기를 이용한 모드 측정)

  • Kang, Min-Sig
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.420-425
    • /
    • 2000
  • When spatially dense velocity distribution is measured by a scanning laser Doppler vibrometer, the Fourier transform method provides the real and imaginary parts of the mode shapes in the form of a polynomial. However the Fourier transform method is often impractical because the independent decomposition property of cosine and sine components into real and imaginary parts, respectively, does not hold due to the leakage problem which commonly occurs in the Fourier transform of harmonic signals. To deal with this problem, a Hilbert transform method is newly proposed in this article. The proposed method is free from the leakage problem and relatively robust to tire scanning error. A simulation example is provided to verify the effectiveness of this method.

  • PDF

A Study on the Performance Analysis of Pulse Repetition Frequency Jitter Compensation for Generating Doppler Profile (도플러 프로파일 생성을 위한 펄스 반복주파수 지터 보상 성능분석에 대한 연구)

  • Lee, Jung-Won;Hwang, Kyu Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.213-220
    • /
    • 2020
  • This paper proposes a method on the performance analysis of pulse repetition frequency jitter compensation for generating Doppler profile. Exact phase compensation of each pulse is required to obtain Doppler profiles under pulse repetition frequency jitter. Three parameters such as velocity, pulse repetition frequency, and carrier frequency are examined to cause errors when conducting the pulse repetition frequency jitter compensation, then assuming well-focused Doppler profiles reflect well-conducted pulse repetition frequency jitter compensation, the proposed method in this paper utilizes the contrast to measure how well Doppler profile is generated. These are validated by electromagnetic computation data and computer simulation. Then, it is concluded which parameter is important on the performance analysis of pulse repetition frequency jitter compensation by using the contrast.

A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information. (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • Kang, Chung-Sin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF