• 제목/요약/키워드: permeance

검색결과 227건 처리시간 0.026초

개선된 퍼미언스법에 의한 영구자석 회전기의 해석 및 설계 (Analysis and Design of Permanent Magnet Motor by the Improved Permeance Method)

  • 정태경;오승석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.175-178
    • /
    • 1998
  • To analyze and design a motor magnetic permeance method and numerical methods such as F.E.M. are used. In this thesis, DC motor is analyzed and designed by the permeance method. Modified Carter coefficient and leakage permeance are presented. A magnetic flux path can be approximated properly by using a equivalent ${\pi}$ network representation adding the leakage coefficient. Finally, effective and easy-to-use program is realized. Experimental analysis and design with an actual motor proves that this program produces reliable results. There are many experimental coefficients in this algorithm and it makes some design errors. Using of this program, an motor engineer can obtain satisfactory characteristic and design value by inputting initial data at once.

  • PDF

막반응기에서의 수성가스전이반응의 성능 분석 (Performance Analysis of Water Gas Shift Reaction in a Membrane Reactor)

  • 임한권
    • 공업화학
    • /
    • 제25권2호
    • /
    • pp.204-208
    • /
    • 2014
  • 본 연구는 1차원 반응기 모델을 이용한 수치 시뮬레이션을 통해 수소투과량, 수소선택도, 사용된 촉매의 양, 급송흐름에서의 $H_2O/CO$ 조성비 및 Ar sweep gas가 막반응기(membrane reactor)에서의 수성가스전이반응의 성능에 미치는 영향을 분석하였다. 막반응기에서 평형상태보다 향상된 수소수율을 얻기 위해선 적어도 100 이상의 수소선택도를 가져야 함이 관찰되었으며, 수소투과량이 계속 증가될 경우에는 수소수율의 증가폭이 점차 감소됨이 보였다. 낮은 수소투과량의 경우에는 촉매량이 증가할수록 초기엔 증가된 CO 전환율을 보이다가 점차 그 증가폭이 감소되었으며, 높은 수소투과량의 경우에는 촉매의 양과 무관하게 높은 CO 전환율이 관찰되었다. 급송흐름에서의 $H_2O/CO$ 조성비가 1.5 이상인 경우엔 수소투과량이 막반응기에서의 CO 전환율에 미치는 영향이 미미하였고, 막반응기에서 평형상태보다 향상된 CO 전환율을 얻기 위해선 적어도 $6.7{\times}10^{-6}mol\;s^{-1}$ 의 Ar 몰유속이 필요함이 밝혀졌다.

A Type of Subsection Model for a Permanent Magnet Bar and its Leakage Permeance Calculation Method in an Open Magnetic Circuit

  • Liang, Huimin;You, Jiaxin;Yang, Wenying;Zhai, Guofu
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.37-42
    • /
    • 2014
  • The equivalent model of a permanent magnet (PM) plays an important role in electromagnetic system calculation. A type of subsection model for a PM bar is established, to improve the accuracy of the traditional equivalent circuit method. The mathematical expression, and its end verification condition, are presented. Based on the analytical method and finite element method, the leakage permeance calculation of a PM bar in an open magnetic circuit is investigated. As an example, for a given certain type of PM bar, the magnetic flux of each section is validated by experiment, and by simulation. This model offers a foundation for building a high accuracy equivalent magnetic PM model in an electromagnetic system.

Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance

  • Shao, P.;Kurth, C.J.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.69-81
    • /
    • 2013
  • The pH-dependent inter-conversion of the three free chlorine species ($Cl_2$, HOCl, OCl-) present in the aqueous hypochlorite solution was theoretically investigated. Each species was found overwhelmingly present in a characteristic pH range. Hypochlorite treatment of the polyamide membrane was carried out over these pH ranges and various membrane responses were observed. As pH is less than 8, membrane tends to be N-chlorinated by $Cl_2$ and HOCl, and N-chlorinated membrane showed reduced water permeance and salt rejection. As pH rises to 10-12, $OCl^-$ appears to be the dominating chlorine species. Membrane hydrolysis was found to well interpret the improved water permeance and salt rejection. When the pH is between 8-10, both N-chlorination and hydrolysis contribute to the response of the membrane, and the treated membrane showed improved salt rejection but reduced water permeation. Excessive hydrolysis occurred while the membrane was treated at pH 13 for the much stronger alkalinity.

기상 화학증착법에 의해 $\alpha$-Alumina 지지관 상에 제조한 Silica막의 수소투과 특성 (Hydrogen Permeance of Silica Membrane Prepared by Chemical Vapor Deposition Method on an $\alpha$-Alumina Support Tube)

  • 김성수;이재홍;서동수;박상욱;서봉국
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.669-677
    • /
    • 1998
  • A porous $\alpha$-alumina tube of 2.5 mm O.D. and 1.9 mm I.D. was used as the support of an inorganic membrane. Macropores of the tube, about 150 nm in size, were plugged with silica formed by thermal decomposition of tetraethylorthosilicate at $600^{\circ}C$. The forced cross-flow CVD method that reactant was evacuated through the porous wall of the support was very effective in plugging macropores. The H$_2$ permeance of the prepared membrane was of the order of $10^{-8}/ molㆍs^{-1}/ㆍm^{-2}/. Pa{-1}$/, while the $N_2$ permeance was below $10^{-11}/ molㆍs^{-1}/ㆍm^{-2}/ㆍPa^{-1}$/ at $600^{\circ}C$. This was comparable to that of silica-modified Vycor glass whose size was 4 nm.

  • PDF

2상 8극 HB형 LPM의 위치오차 해석 (Position Accuracy Error Analysis in 2 Phase 8 Pole HB Type LPM)

  • 김성헌;이은웅;이동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.38-41
    • /
    • 1997
  • As the LPM is used for position accuracy decision device it is required that both the reason of posion error and the definition of position itself should be cleared. In this study, the precision of the position decision of LPM is affected by the geometrical shape such as tooth shape or processing accuracy. By using the analysis of magnetic circuit, we calculated the permeance come up with the gap. Once the thrust force has been obtained, the permeance due to the mechanical error of the pole pitch and the tooth pitch becomes the error of thrust force. We confirmed as well that it is being affected by the difference due to the variation of the airgap permeance.

  • PDF

계기용 영구자석형 LDM의 설계제작 및 기본특성 연구 (Design and Analysis of Permanent Magnet Type LDM for Implementation)

  • 김용;백수현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.56-62
    • /
    • 1999
  • This paper is concerned with the design and the construction of a moving magnet type linear DC motor(MM type LDM) for instrumentation. A mathematical model for the design of a LDM is developed and a permeance method is used to calculate the effective flux density in the air gap. The flux distribution in the air gap is analyzed and the width of iron core should be determined in order not to saturate the iron core by caluclating maxmum flux density. The design data culculated by a permeance method are compared with the analyzed results using FEM(MAXWELL 2D). The errors between two results are corrected. The tested LDM is constructed using the corrected design data. The results of experiment for thrust characteristics are compared with simulation.

  • PDF

경사 편심에 의한 유도전동기의 자기흡인력 평가 (Calculation of Unbalanced Magnetic Pull of Induction Motors due to Rotor Misalignment)

  • 김선화;양보석;김현철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1321-1327
    • /
    • 2006
  • This paper presents the calculation of unbalanced magnetic pull (UMP) that causes rotor misalignment in induction motor. The excessive noise and vibration will be occurred by means of rotor misalignment. Angular misalignment of rotor will produce air-gap permeance wave which is function of axial and circumferential coordinate. In this paper, the UMP is calculated using permeance and magneto motive force (MMF) in the case of static and dynamic misalignment. Based on the percentage of misalignment, the result shows that the UMP and magnetic pressure are increased according to the increasing of misalignment. The UMP is occurred not only in It frequency component but also the others.

  • PDF

퍼미언스 방법을 이용한 스위치드 릴럭턴스 전동기의 인덕턴스 산정 (Inductance Calculation in a Switched Reluctance Motor using Permeance Method)

  • 이치우
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1836-1842
    • /
    • 2012
  • Torque is proportional to the rate of change of inductance in a switched reluctance motor (SRM), and hence, phase inductance is an important parameter in determining the behavior of an SRM. Therefore, the accurate prediction of inductance with respect to rotor position makes a significant contribution to designing an SRM and its analytical approach is not straightforward due to nonlinear flux distribution. Although several different approaches using a finite element analysis (FEA) or curve-fitting tool have been employed to compute phase inductance [2-5], they are not suitable for a simple design procedure because the FEA necessitates a large amount of time in both modeling and solving with complexity for every motor design, and the curve-fitting requires the data of flux linkage from either an experimental test or an FEA simulation. In this paper, phase inductance is predicted by means of a permeance method, and the proposed approach is analytically verified in terms of the accuracy of estimated inductance compared to inductance obtained by FEA.

투습성에 따른 단열재의 단열성능평가 및 고찰 (The estimation on the insulation performance of thermal insulation materials according to water vapor permeance)

  • 김석현;박종일;이민우;홍진관
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1012-1018
    • /
    • 2006
  • In this study, the insulation performance of thermal insulation materials such as glass wool, polyetylene and flexible lastomeric foam according to water vapor permeance was estimated by using experimental correlation equation. The results showed the conductivity increment of flexible lastomeric foam which has very low-permeability (${\le}0.15[ng/{\cdot}s{\cdot}Pa]\;or\;{\mu}{\ge}1,000$) is about 50% lower than that of glass wool with the lapse of ten years. The conclusion is that moisture inevitably accumulated in permeable Insulations reduces insulation performance and also accelerates surface condensation in the case of cold water system.

  • PDF