• Title/Summary/Keyword: permeability model

Search Result 580, Processing Time 0.042 seconds

Optimal Test Condition by Ultrasonic Simulation (초음파 시뮬레이션을 이용한 최적의 탐상조건)

  • Huh, Sun-Chul;Park, Young-Chul;Boo, Myung-Hwan;Kang, Jung-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.45-54
    • /
    • 1999
  • Non destructive test is applied to revise mechanical strength and assume material strength or defect of material, equipment and structure, instead of fracture test. Especially, ultrasonic test has the characteristics such as an excellent permeability high-sensitiveness to fine defect and an almost exact measurement for position, size and direction of inner defect which differ from other non destructive tests. In this study, the program is developed to evaluate optimal testing condition, to distinguish obstacle echo and defect position. This program on the basic of Ray-Tracing model shows generation and processing of ultrasonic pulse. The simulation is compared with testing in the 3 cases of an oblique angle transducer like $45^{\circ},\;60^{\circ}\;and\;70^{\circ}$. The test result for all conditions is well compared with simulation result when relative not is within $0.1{\sim}7.2%$. And the course of several echos is simply assumed through simulation.

  • PDF

Evolution of reaction zones in reactive barriers consisting of calcite and glass beads

  • Jeong Gon, Kim;Gwang Man, Lee;Ik Hwan, Go
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.19-22
    • /
    • 2004
  • Two-dimensional modeling studies using TOUGHREACT were conducted to investigate the coupling between flow and transport developed as a consequence of differences in density, dissolution/ precipitation, and medium heterogeneity. The model includes equilibrium reactions for aqueous species, kinetic reactions between tile solid phases and aqueous constituents, and full coupling of porosity and permeability changes resulting from precipitation and dissolution reactions in porous media. Generally, the evolutions in the concentrations of the aqueous phase are intimately related to the reaction-front dynamics. Plugging of the medium contributed to significant transients in patterns of flow and mass transport.

  • PDF

Experimental study of electro-osmotic hydraulic conductivity changes with voltage gradients (전압경사에 따른 전기삼투 투수계수의 변화에 대한 실험적 연구)

  • Yoon, Dong-Wook;Kim, Hyun-Ki;Cho, Nam-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1002-1007
    • /
    • 2010
  • This study evaluates the electro-osmotic hydraulic conductivity for the clay specimen by applying the series of the voltage gradient simultaneously with different stress conditions. The test results shows that the shrinkage of voids corresponds to the linear decrease in the electro-osmotic seepage velocity, and the changes of electro-chemical characteristics in the specimen induces the gradual decrease of the electro-osmotic seepage velocity with the constant voltage gradient.

  • PDF

Anti-inflammatory Activities of Torilis japonica Fruit (사상자의 항염증작용)

  • Kim, Sang-Mee;Kim, Tae-Hee;Lee, Eun-Bang
    • Korean Journal of Pharmacognosy
    • /
    • v.29 no.4
    • /
    • pp.384-390
    • /
    • 1998
  • The methanol extract of Torilis Fructus showed potent anti-edematous effect in carrageenan-induced paw edema in rats. Systematic fractionation of the extract with hexane, chloroform, ethyl acetate and butanol resulted in potent anti-edematous action only in hexane fraction at an oral dose of 237 mg/kg which is corresponding to 4.8 g of raw Fructus. This hexane fraction showed inhibitory effects at 77 mg/kg p.o on vascular permeability in mice, at 8mg/pouch on leucocyte emigration in rats, and at 120 mg/kg p.o. on adjuvant arthritis model in rats. These results demonstrate that hexane fraction of the extract possesses potent anti-inflammatory effect which may support its traditional uses.

  • PDF

Impedance Analysis of a Solenoid Eddy Current Coil with Cylindrical Two-conductor Rods (원통형 2-도체를 가진 솔레노이드 와전류 코일의 임피던스 해석)

  • 김성덕;이상래
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.89-98
    • /
    • 1998
  • Some analytic results for a solenoid eddy current coil to test nondestructive conducting materials are described in this paper. Normalized impedance of solenoid coil encircling cylindrical conducting tubes or tow-conductor rods is analyzed. Electrical and magnetic properties such as conductivity, permeability and exciting frequency as well as the geometric ones of fill factor or radius ratio of the conductor are also considered. Impedance characteristics of the models obtained by numerical analysis are examined. Validation of the model is carried out using several samples of non-ferromagnetic conducting tubes and 2-conductor rods.

  • PDF

Finite Element Analysis of Magnetostrictive Linear Actuator (자왜재료를 이용한 선형 작동기의 유한요소 해석)

  • Kim, Yoon-Chang;Kim, Jae-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.356-362
    • /
    • 2007
  • Magnetostrictive materials have been used for linear actuators due to its large strain, large force output with moderate frequency band in the presence of magnetic field. However their performance analysis is difficult because of nonlinear material behaviors in terms of coupled strain-magnetic field dependence, nonlinear permeability, pre-stress dependence and hysteresis. This paper presents a finite element analysis technique for magnetostrictive linear actuator. To deal with coupled problems and nonlinear behaviors, a simple finite element approach is proposed, which is based on separate magnetic field calculation and displacement simulation. The finite element formulation and an in-house program development are illustrated, and a simulation model is made for a magnetostrictive linear actuator. The fabrication and performance test of the linear actuator are explained, and the performance comparison with simulation result is shown. Since this approach is simple, it can be applied for analyzing magnetostrictive underwater projectors and ultrasonic transducers.

A Computationally Efficient Finite Element Analysis Algorithm Considering 2-D Magnetic Properties of Electrical Steel Sheet

  • Yao, Yingying;Li, Wei;Yoon, Hee-Sung;Fujiwara, Koji;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.385-390
    • /
    • 2008
  • For taking account of the two-dimensional magnetic properties of a grain-oriented electrical steel sheet, the effective anisotropic tensor reluctivity is examined, and a computationally efficient algorithm is suggested by using the response surface method to model the two-dimensional magnetic properties. It is shown that the reconstructed two-dimensional magnetic properties are fairly effective to stabilize the convergence characteristics of the Newton-Raphson iteration in the nonlinear magnetic field analysis.

Finite element analysis of concrete cracking at early age

  • Aurich, Mauren;Filho, Americo Campos;Bittencourt, Tulio Nogueira;Shah, Surendra P.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.5
    • /
    • pp.459-473
    • /
    • 2011
  • The study of the early age concrete properties is becoming more important, as the thermal effects and the shrinkage, even in the first hours, could generate cracks, increasing the permeability of the structure and being able to induce problems of durability and functionality in the same ones. The detailed study of the stresses development during the construction process can be decisive to keep low the cracking levels. In this work a computational model, based on the finite element method, was implemented to simulate the early age concrete behavior and, specially, the evaluation of the cracking risk. The finite element analysis encloses the computational modeling of the following phenomena: chemical, thermal, moisture diffusion and mechanical which occur at the first days after the concrete cast. The developed software results were compared with experimental values found in the literature, demonstrating an excellent approach for all the implemented analysis.

Pharmaceutical Studies on Improved Bioavailability of Indoprofen by ${\beta}-Cyclodextrin$ Complexation ( II ) (난용성약물(難溶性藥物)인 Indoprofen의 ${\beta}-Cyclodextrin$복합체(複合體) 형성(形成)에 따른 생체이용률(生體利用率)의 개선(改善)에 관한 약제학적(藥劑學的) 연구(硏究) (제2보)(第二報))

  • Han, Kun;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.14 no.1
    • /
    • pp.19-30
    • /
    • 1984
  • The pharmaceutical characteristics of solid indoprofen inclusion complex such as dissolution, permeation through a cellophane membrane, model analysis of interfacial tranesfer, absorption behaviors in rat intestine, and the plasma concentration of indoprofen after oral administrations to rabbits were examined in comparison with those indoprofen alone. The inclusion complex obtained by freeze-drying method showed the higher dissolution rate and membrane permeability among the test powders, and increased significantly the amont of indoprofen absorbed in rat intestine and the levels of plasma concentration of indoprofen after oral adminstrations to rabbits. The increase of bioavailability of $indoprofen-{\beta}-cyclodextrin$ complex was considered due to the increased solubility and dissolution rate of solid powder form.

  • PDF

Ultrasonic Simulation for Test Condition Estimate (탐상조건 예측을 위한 초음파 시뮬레이션)

  • Huh, Sun-Chul;Park, Young-Chul;Lee, Kwang-Young;Park, Won-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.37-44
    • /
    • 2001
  • Ultrasonic testing has a characteristics such as excellent permeability, high-sensitivity to find defect and an almost exact measurement for position. size and direction of inner defect, which differ from other non-destructive testing. In the study, we developed program into optimal testing condition, to distinguish obstacle echo and defect position. This program shows generation and processing of ultrasonic pulse. We compared simulation with ultrasonic test in 45$^\circ$, 60$^\circ$and 70$^\circ$transducer. Test results were in accordance with simulation within 0.1~7.2%.

  • PDF