• Title/Summary/Keyword: permanent.

Search Result 6,700, Processing Time 0.035 seconds

A Study on the Iron Losses in Flux-Switching Permanent Magnet Machines

  • Shin, Heung-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.699-703
    • /
    • 2018
  • Flux-switching permanent magnet machines (FSPMM) have doubly-salient and simple structures making it cost effective and suitable for mass production. In addition, it is possible to increase the rotor rotating speed and concentrate the flux of the permanent magnet on the air-gap. Due to these merits, the FSPMM can be applied to the various industry applications. To improve the performance, various design variables need to be studied in terms of design techniques. In this paper, we especially concentrate on the distribution of iron losses using a two-dimensional finite-element method (2D FEM). As a result, we can get an information for high efficiency FSPMM design.

Neural Network Controller for a Permanent Magnet Generator Applied in Wind Energy Conversion System

  • Eskander, Mona N.
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.46-54
    • /
    • 2002
  • In this paper a neural network controller for achieving maximum power tracking as well as output voltage regulation, for a wind energy conversion system (WECS) employing a permanent magnet synchronous generator is proposed. The permanent magnet generator (PMG) supplies a dc load via a bridge rectifier and two buck-boost converters. Adjusting the switching frequency of the first buck-boost converter achieves maximum power tracking. Adjusting the switching frequency of the second buck-boost converter allows output voltage regulation. The on-time of the switching devices of the two converters are supplied by the developed neural network (NN). The effect of sudden changes in wind speed and/ or in reference voltage on the performance of the NN controller are explored. Simulation results showed the possibility of achieving maximum power tracking and output voltage regulation simulation with the developed neural network controllers. The results proved also the fast response and robustness of the proposed control system.

Current-Sensorless Maximum Torque per Ampere Control for a Surface Mounted Permanent Magnet Synchronous Motor with Low-Resolution Position Sensor (저분해능 위치센서를 갖는 표면부착형 영구자석 동기전동기의 전류센서 없는 단위 전류 당 최대 토크 제어)

  • Lee, Kwang-Woon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.204-210
    • /
    • 2009
  • This paper proposes a novel current-sensorless maximum torque per ampere control for a surface mounted permanent magnet synchronous motor with low-resolution position sensor. A direct axis current is estimated from the mathematical model of the permanent magnet synchronous motor and the phase angle between direct and quadrature axis voltage commands is controlled to adjust the estimated direct axis current to zero, thus a maximum torque per ampere control can be achieved. The proposed method is suitable for low cost applications with slow dynamic response characteristics.

An Analysis on the Discrimination of the Information Usage Pattern by Pyeong-type Tenants: Focused on Tenants between Kohom's Permanent and Temporary Public Rental Housing (주택평형별 거주자들의 정보화 이용 패턴 차별성 분석 : 주택관리공단의 영구.국민 임대주택을 중심으로)

  • Ko, Jong-Moon;Kim, Shin-Pyo
    • Journal of Digital Convergence
    • /
    • v.5 no.1
    • /
    • pp.117-130
    • /
    • 2007
  • This paper examines whether there exists discrimination of the information usage pattern between tenants of permanent and temporary public rental housing in Korea. Moreover, we focus to examine on that matters between two groups, $7{\sim}12$ pyeongs and $11{\sim}24$ pyeongs that indicate permanent and temporary public rental housing respectively. The results derived in this paper can be summarized as follows: there exists statistical significance in using computer, internet, communication and broadcasting, on the other hand, insignificance in using satellite communication and telephone between them. The implication of this results shows that as widen income gap, also widen gaps in using computer and internet between them. Thus government public rental housing policy should focus to make narrow income gap to diminish information gap between those groups.

  • PDF

Minimization of Cogging Force in a Stationary Discontinuous Armature Linear Permanent Magnet Motor at the Outlet Edge

  • Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.288-293
    • /
    • 2011
  • Generally, the discontinuous armature permanent magnet linear synchronous motor (PM-LSM) is composed by the stator block (accelerator, re-accelerator, and decelerator) and the free running section. However, the stationary discontinuous armature design involves the velocity variation of the mover during drive when the armature's non-installation part changes over to installation part as a result of the outlet edge of the armature. Therefore, we considered deforming the shape of the outlet edge at the armature and apply skew on the permanent magnet by displacing the two magnet segments of each pole. This paper presents the results of a three-dimensional (3-D) numerical analysis with a finite element method (FEM) of the force exerted by the outlet edge.

Micromagnetic Modeling of Spin-valve MR Head with Synthetic Antiferromagnet (SyAF)

  • Tahk, Y.W;Lee, K.J;Lee, T.D
    • Journal of Magnetics
    • /
    • v.7 no.2
    • /
    • pp.55-58
    • /
    • 2002
  • MR transfer behaviors of the permanent magnet biased spin valve MR sensors with SyAF (synthetic antiferromagnet) layers were studied by micromagnetics modeling. For narrow track MR heads, various height to width ratios were considered together with strength of permanent magnets which stabilities the free layed As the MR sensor width is reduced to $0.12 \mu{m}$, sensor height less than 0.09 ${\mu}{\textrm}{m}$ is needed to show good linearity and the Mr.t of permanent magnets smaller than 0.2 memu/$cm^2$ is sufficient for the domain stabilization. The conditions for single domain behavior of the free layer were also investigated through optimizing the biasing strength of permanent magneto the shield gap and the aspect ratio of MR sensor.

The Study on a Residents' Demands of Support Facilities for Self-sufficiency and Design of Permanent Rental Housing -With Reference to Man-soo 7 Estate in Incheon- (영구임대아파트 자족지원시설 수요 및 설계 연구 -인천 만수주공 7단지를 사례로-)

  • Park, Byong gyu;Kim, Min Kyung
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Permanent rental housing complex is subjected to both an increase in the crime rate due to its residential population structure and social, economic isolation for insecurd income of the residents. It should be considered that the densely populated area with low-income group of the city causing many problems related with the community. This study focused on the Man-soo 7 housing estate in Incheon with the area's average scale and ratio is made as an effort to include the residents who live in the permanent rental housing area among the members of the healthy community. The result of the research suggests the method of housing improvement to establish the successful support institution for self-sufficiency of the low income inhabitants analazying the demand of the residents through a survey categorized into resident support system, public workplace and inhabitant participation.

Torque Characteristics Analysis of Interior Permanent Magnet Synchronous Motor According to Pole Arc Ratio (극호비 변화에 따른 영구자석 매입형 동기전동기의 토크 특성 해석)

  • LEE Kab-Jae;Kim Ki-Chan;Lee Jong-In;Kwon Joong-Lok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • The torque characteristics of permanent magnet(PM) motor is varied according to magnet width. In this paper, the design method of magnet and magnetic circuit is proposed in order to improve the torque of Interior Permanent Magnet Synchronous Motor(IPMSM). This paper presents the effects of pole arc ratio and salient pole ratio on the torque and torque ripple in the IPMSM with concentrated winding.

Optimal Design of an Outer-rotor Flux-switching Permanent Magnet Motor for High Speed Operation (외전형 FSPM(Flux Switching Permanent Magnet) 전동기의 고속 운전을 위한 최적 설계)

  • Lee, Jae-Kwang;Jang, Jin-Seok;Kim, Byung-Teak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2035-2042
    • /
    • 2011
  • In this paper, we proposed the outer-rotor type of FSPM motor for high speed operation and optimized motor shape. First of all, combinations of pole and slot numbers are examined for the optimal back-EMF and cogging torque, then optimizes the better shape design of the permanent magnet, rotor pole width. Further, The winding turns are obtained by circle of the voltage limit equation and motor parameters to minimize the current and to improve the efficiency. As a result, the performance of the designed model is satisfied, and it is verified through a two-dimensional finite element method (2D-FEA).

Characteristic Analysis of Double sided Permanent Magnet Linear Generator by using Analytical Method (해석적 방법을 이용한 양측식 선형 영구자석 발전기의 특성해석)

  • Kang, Han-Bit;Choi, Jang-Young;Kim, Kyong-Hwan;Hong, Keyyong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.652-659
    • /
    • 2014
  • This paper deals with characteristic analysis of double sided permanent magnet linear generator using analytical method. We derived magnetic field solutions produced by permanent magnet and armature reaction based on the 2D polar coordinate and magnetic vector potential. based on the derived magnetic field solutions, Induced voltage is obtained when arbitrary sinusoidal input condition. In addition, electrical parameters such as back-EMF constant, resistance, and inductance are obtained. Finally, generating performance characteristic at the rated load and various load is examined by using equivalent circuit.