• Title/Summary/Keyword: period of vibration

Search Result 449, Processing Time 0.024 seconds

Research on Relationship between Natural Vibration Periods and Structural Heights for High-rise Buildings and Its Reference Range in China

  • Xu, Peifu;Xiao, Congzhen;Li, Jianhui
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.49-64
    • /
    • 2014
  • Natural vibration period is an important parameter for high-rise building, Based on 414 high-rise buildings completed or passed over-limit approval in China, the distribution law of natural vibration periods is analyzied. In order to satisfy the design requirements, such as global stability, story drift limit and minimum shear-gravity ratio, the reference ranges of fundamental periods $T_1$ are $0.3{\sqrt{H}}{\sim}0.4{\sqrt{H}}$ when the structural heights $H{\geq}250m$, when 150 m ${\leq}$ H < 250m, $T_1=0.25{\sqrt{H}}{\sim}0.4{\sqrt{H}}$, when 100 m ${\leq}$ H < 150 m, $T_1=0.2{\sqrt{H}}{\sim}0.35{\sqrt{H}}$, when 50 m $ {\leq}$ H < 100m, $T_1=0.15{\sqrt{H}}{\sim}0.3{\sqrt{H}}$. These can provide reference data for controlling mass and rigidity of high-rise buildings.

The effect of rolling stock vibration on running safety(derailment) (차량 진동특성이 주행안전도(탈선)에 미치는 영향)

  • Lee Kwan-Sup;Shin Yu-Jeong;Yoon Ji-Na
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.761-766
    • /
    • 2004
  • This paper describes how to measure the running safety using vibration accelerometers theoretically, and considers the effect of vibration parameters, such as amplitude and period, on the running safety by numerical analysis, which shows that the running safety are decreased as those parameters are increased.

  • PDF

성덕대왕신종의 진동 및 음향 특성

  • 김석현;김정헌;정지덕;이장무
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.7
    • /
    • pp.534-541
    • /
    • 2002
  • Vibration and sound characteristics of King Song-Dok Bell are ivesigated. Natural frequencies. vibration modes and beat period of the bell are precisely measured. The effect of striking position and the position of nodal lines on the beat characteristics is examined. It is first found that the beat characteristics are quote different according to the position on the bell surface and clear beat is periodically generated on the circumference. It turns out that in King Song-Dok Bell, Dangjwa(the present striking position) is located at the position which makes a beat in the first vibration mode, as welt as it produces very clear beat In the second vibration mode.

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • v.51 no.4
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

Effect on Vibration According to the Load Capability and Elapsed Year of Power Transformer(154kV) in Operation (운전 중인 전력용 변압기(154kV)의 부하용량과 경년이 진동에 미치는 영향)

  • Kim, Young-Dal;Kim, Sung-Joong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.172-177
    • /
    • 2009
  • Most of the causes of the failures of power transformers in operations are mechanical defects due to vibration. To identify these causes, the vibration phenomenon was measured from the power transformers in operation in the substations under the Daejeon power transmission district office of KEPCO. The measurement was performed in a 6${times}$4 structure on one side of the transformer. The vibration of the measured points was presented in 2D and 3D, and analyzed. The results according to the period in use of the transformer and the load applied to the transformer were analyzed. These results will be used as basic data to establish the vibration standard for the power transformer, In addition, with a load capability and vibration phenomenon correlation and regression analysis to identify by way of function was reached. And the vibration phenomenon pass a years with changes and to analyze correlation, was estimated to bring in the function. And then through the analysis of power transformers to set standards based on vibration data was used to.

Development of Simulation Tool to predict dynamic motion of Linear Compressor (리니어 압축기의 동적거동예측 Simulation Tool 개발)

  • Jeon, Soo-Hong;Lee, Hyo-Jae;Jeong, Weui-Bong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1026-1030
    • /
    • 2007
  • A linear compressor used in a refrigerator has higher energy efficiency than a reciprocating compressor. But its vibration level is still severe than others. The vibration level of linear compressor at the frequency of 60Hz is dominant since it is the exciting frequency of a motor. Experimental approach to reduce the vibration needs much effort and long period. In this paper, simulation tool to predict the vibration of the shell of the linear compressor was developed. The piston, body and shell are assumed to be rigid, while the loop pipe is flexible. The results by the developed tool showed good agreements with those by experiments.

  • PDF

Characteristic Vibration analysis of the Ox-Reactor Agitator (산소 반응 교반기의 진동 특성 분석)

  • Jang, Young-Seok;Lim, Jang-Ik;Gu, Dong-Sik;Kim, Hyo-Jung;Choi, Byung-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.986-989
    • /
    • 2008
  • Recently the agitator are being widely used in the machine plan in order to increase the petrochemical industry. The agitator normally consist of impeller, shaft, hub, reduction gear and the driving motor. It is one of the key design issue to confirm that the vibration caused by the rotation of the shaft should not coincide with the natural frequency of the shaft itself. And petrochemical industry as well as plants have been in operation for long period beyond their original design lives. In this paper the vibration of Ox-Reactor Agitator is measured for check machine condition. The result of diagnosis and solution is discussed in this paper.

  • PDF

Vibration and Acoustic Noise characteristic on SRM with compensating winding that two stage commutation is used at commutation action (2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성)

  • Lee, Jong-Gun;Jung, Tae-Uk;An, Young-Joo;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.55-57
    • /
    • 1999
  • SRM Drives generate large vibration and acoustic noise because it is rotated by step pulse mmf and switching commutation mechanism. The main vibration source of SRM Drive is generated by rapidly variation of radial force when phase winding current is extinguished for commutation action. So the rapidly variation of radial force is repressed firstly to reduce vibrating force of SRM Drive. This paper suggests the vibration reduction method that SRM Drive with unidirect-short compensation winding is excited by a two stage commutation method at commutation period. This reduction effect of vibration is verified with the result obtained in the test of prototype machine.

  • PDF

The Dynamic Characteristics for Low-rise Reinforced Concrete Buildings by Vibration Measurements (진동계측에 의한 저층 철근콘크리트조 건물의 동적특성)

  • Kang, Dong-Gyun;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.3 no.1 s.7
    • /
    • pp.47-55
    • /
    • 2003
  • This paper is concerned with the dynamic characteristics of buildings, especially with the measurement of the natural frequencies(natural periods) and the damping. Process of ambient vibration and synchronized human excitation tests for natural period and damping are given. Data from measurement on 16 reinforced concrete buildings in Seoul and Seoul national university of technology are given. 16 Low-rise Reinforced concrete buildings are measured for ambient vibration to obtain the vibrations characteristics. The natural periods obtained by ambient vibration measurements are compared with those of forecast model suggested by standards and foreign researchers. The natural periods show a clear dependence on building height. On the other hand, the damping ration scatter under the influence of various factors, for example, building height and natural frequency.

  • PDF

Evaluation of Vertical Vibration Performance of Tridimensional Hybrid Isolation System for Traffic Loads (교통하중에 대한 3차원 하이브리드 면진시스템의 수직 진동성능 평가)

  • Yonghun Lee;Sang-Hyun Lee;Moo-Won Hur
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.70-81
    • /
    • 2024
  • In this study, Tridimensional Hybrid Isolation System(THIS) was proposed as a vibration isolator for traffic loads, combining vertical and horizontal isolation systems. Its efficacy in improving serviceability for vertical vibration was analytically evaluated. Firstly, for the analysis, the major vibration modes of the existing apartment were identified through eigenvalue analysis for the system and pulse response analysis for the bedroom slab using commercial structural analysis software. Subsequently, a 16-story model with horizontal, vertical and rotational degrees of freedom for each slab was numerically organized to represent the achieved modes. The dynamic analysis for the measured acceleration from an adjacent ground to high-speed railway was performed by state-space equations with the stiffness and damping ratio of THIS as variables. The result indicated that as the vertical period ratio increased, the threshold period ratio where the slab response started to be suppressed varied. Specifically, when the period ratio is greater than or equal to 5, the acceleration levels of all slabs decreased to approximately 70% or less compared to the non-isolated condition. On the other hand, it was ascertained that the influence of damping ratios on the response control of THIS is inconsequential in the analysis. Finally, the improvement in vertical vibration performance of THIS was evaluated according to design guidelines for floor vibration of AIJ, SCI and AISC. It was confirmed that, after the application of THIS, the residential performance criteria were met, whereas the non-isolated structure failed to satisfy them.