• 제목/요약/키워드: peri-implant tissue

검색결과 103건 처리시간 0.023초

임상가를 위한 특집 2 - 임플란트 주위염의 병인론적 위험요소에 대한 문헌적 고찰 (Etiological risk factors of peri-implantitis : a literature review)

  • 황재호
    • 대한치과의사협회지
    • /
    • 제51권12호
    • /
    • pp.637-642
    • /
    • 2013
  • Because the implant is regarded as a common treatment. It is clinically important that systemic and local risk factor of threatening peri implant mucosa should be considered during the process. The most risk factors are detected in clinical diagnosis, but it might be difficult and not clear to recognize systemic or combined factors. This article reviews risk factors of peri-implantitis. Local factors are biomechanics, periodontal soft tissue characteristics, infected site and oral hygiene. Systemic factors are alcohol, smoking and genetic traits.

Radiation effect on peri-implant tissue after implantation

  • Kweon, Hyeog-Sin;Song, Kwang-Yeob
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.291-309
    • /
    • 2000
  • Statement of problem. There were several studies on the effects of irradiation to peri-implant bone tissue. However, no clear biological effect of irradiation on peri-implant bone tissue was reported yet. Purpose. This study compared the effect of irradiation on the surrounding tissue of a HA-coated implant fixture with controls. Material and methods. 6 Steri-Oss implants were implanted into the femur of 6 mongrels. The implanted dogs were divided into three groups and received irradiation. After 1 month, 2months and 4 months healing period, the histologic examination and mobility test and digital radiographic imaging analyses were performed to compare the control and experimental group respectively. Results. The irradiated group showed slower healing than control group in light microscopic observations. The mobility test demonstrated significant less number (Periotest) in control group than that of irradiated groups. The digital radiographic imaging analysis showed that the bone density of irradiated group was higher than control group. Conclusion. Generally, control group showed favorable biological response and less mobility than irradiated group. The conflict result of bone density value were measured by the digital radiographic imaging analysis. The digital radiographic imaging analysis needs more research in future.

  • PDF

Er,Cr:YSGG 레이저를 조사한 임플란트 표면의 주사전자현미경적 연구 (SCANNING ELECTRON MICROSCOPIC STUDY OF IMPLANT SURFACE AFTER Er,Cr:YSGG LASER IRRADIATION)

  • 조필귀;민승기;권경환;김영조
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권5호
    • /
    • pp.454-469
    • /
    • 2006
  • Today, there is considerable evidence to support a cause-effect relationship between microbial colonization and the pathogenesis of implant failures. The presence of bacteria on implant surfaces may result in an inflammation of the peri-implant mucosa, and, if left untreated, it may lead to a progressive destruction of alveolar bone supporting the implant, which has been named as peri-impantitis. Several maintenance regimens and treatment strategies for failing implants have been suggested. Recently, in addition to these conventional tools, the use of different laser systems has also been proposed for treatment of peri-implant infections. As lasers can perform excellent tissue ablation with high bactericidal and detoxification effects, they are expected to be one of the most promising new technical modalities for treatment of failing implants. It is introduced that Er,Cr:YSGG laser, operating at 2780nm, ablates tissue by a hydrokinetic process that prevents temperature rise. We studied the change of the titanium implant surface under scanning electron microscopy after using Er,Cr:YSGG laser at various energies, irradiation time. In this study, Er,Cr:YSGG laser irradiation of implant fixture showed different effects according to implant surface. Er,Cr:YSGG laser in TPS surface with RBM not alter the implant surface under power setting of 4 Watt(W) and irradiation time of 30sec. But in TPS surface with $Ca_3P$ coating alter above power setting of 2W and irradiation time of 10sec. TPS surface with RBM showed microfracture in 4W, 30sec and TPS surface with $Ca_3P$ coating showed destruction of fine crystalline structure, melting in excess of 2W, 10sec. We concluded that proper power setting, air, water of each implant surface must be investigated and implant surface must be irradiated under the damaged extent.

Immediate implant placement in conjunction with guided bone regeneration and/or connective tissue grafts: an experimental study in canines

  • Lim, Hyun-Chang;Paeng, Kyeong-Won;Kim, Myong Ji;Jung, Ronald E.;Hammerle, Christoph HF.;Jung, Ui-Won;Thoma, Daniel S.
    • Journal of Periodontal and Implant Science
    • /
    • 제52권2호
    • /
    • pp.170-180
    • /
    • 2022
  • Purpose: This study was conducted to assess the effect of hard and/or soft tissue grafting on immediate implants in a preclinical model. Methods: In 5 mongrel dogs, the distal roots of P2 and P3 were extracted from the maxilla (4 sites in each animal), and immediate implant placement was performed. Each site was randomly assigned to 1 of the following 4 groups: i) gap filling with guided bone regeneration (the GBR group), ii) subepithelial connective tissue grafting (the SCTG group), iii) GBR and SCTG (the GBR/SCTG group), and iv) no further treatment (control). Non-submerged healing was provided for 4 months. Histological and histomorphometric analyses were performed. Results: Peri-implant tissue height and thickness favored the SCTG group (height of periimplant mucosa: 1.14 mm; tissue thickness at the implant shoulder and ±1 mm from the shoulder: 1.14 mm, 0.78 mm, and 1.57 mm, respectively; median value) over the other groups. Bone grafting was not effective at the level of the implant shoulder and on the coronal level of the shoulder. In addition, simultaneous soft and hard tissue augmentation (the GBR/SCTG group) led to a less favorable tissue contour compared to GBR or SCTG alone (height of periimplant mucosa: 3.06 mm; thickness of peri-implant mucosa at the implant shoulder and ±1 mm from the shoulder: 0.72 mm, 0.3 mm, and 1.09 mm, respectively). Conclusion: SCTG tended to have positive effects on the thickness and height of the periimplant mucosa in immediate implant placement. However, simultaneous soft and hard tissue augmentation might not allow a satisfactory tissue contour in cases where the relationship between implant position and neighboring bone housing is unfavorable.

임상가를 위한 특집 3 - Peri-implantitis의 regeneration therapy 증례 보고 (Use of Bovine-derived bone mineral (Bio-Oss Collagen$^{(R)}$) in surgical treatment of peri-implantitis: A case report)

  • 조영재
    • 대한치과의사협회지
    • /
    • 제51권12호
    • /
    • pp.650-657
    • /
    • 2013
  • The aim of this study was to achieve healing of Peri-implantitis defects and hard tissue augmentation using a bovine-derived bone mineral on the defect site. Two patients were treated with the surgical approach. With a full muco-periosteal flap elevation, the implant surfaces were exposed and granulation tissue removed around the implant and between the threads. Each surface of the contaminated implant was prepared with the air-abrasive device(PerioFlow$^{(R)}$) for decontamination. Bovine-derived bone mineral(Bio-Oss collagen$^{(R)}$) was then used to fill the defects and muco-periosteal flaps sutured to achieve transmucosal healing. Radiographs and clinical photographs were taken before and after 6 months of healing and an estimate of bone fill was assessed. Within the limits of the present case report, a surgical approach in treatment of peri-implantitis defects using a collagen form of bovine bone mineral was visited. Although limited, the two cases showed the stability and biocompatibility of a bovine-derived bone mineral and effectiveness of air-abrasive device(PerioFlow$^{(R)}$) as a decontamination method.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

임상가를 위한 특집 3 - Peri-implantitis의 regeneration therapy 증례 보고 (Use of Bovine-derived bone mineral (Bio-Oss Collagen$^{(R)}$) in surgical treatment of peri-implantitis: A case report)

  • 조영재
    • 대한치과의사협회지
    • /
    • 제51권12호
    • /
    • pp.643-649
    • /
    • 2013
  • The aim of this study was to achieve the healing of peri-implantitis defects and the hard tissue regeneration using the augmentation of a xenograft on defect site. Two patients were treated with the surgical approach. With a full muco-periosteal flap elevation, the implant surfaces were exposed and taken the debridement of granulation tissue around the abutment. Each surface of the abutments was prepared with the air-abrasive device (PerioFlow$^{(R)}$) for decontamination. Bovine-derived bone mineral (Bio-Oss collagen$^{(R)}$) was then used to fill the defects, and no membrane was placed on the grafting site. Radiographs and clinical photo was taken to compare from baseline status. Within the limits of the present case, this case shows the significance of the surgical treatment of peri-implantitis. And this also verifies the stability of bovine-derived bone mineral and effectiveness of Air-abrasive device (PerioFlow$^{(R)}$).

In situ dental implant installation after decontamination in a previously peri-implant diseased site: a pilot study

  • Kim, Young-Taek;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제42권1호
    • /
    • pp.13-19
    • /
    • 2012
  • Purpose: The aim of this study was to examine whether a previous peri-implantitis site can affect osseointegration, by comparing implant placement at a site where peri-implantitis was present and at a normal bone site. A second aim of this study was to identify the tissue and bone reaction after treating the contaminated implant surface to determine the optimal treatment for peri-implant diseases. Methods: A peri-implant mucositis model for dogs was prepared to determine the optimal treatment option for peri-implant mucositis or peri-implantitis. The implants were inserted partially to a length of 6 mm. The upper 4 mm part of the dental implants was exposed to the oral environment. Simple exposure for 2 weeks contaminated the implant surface. After 2 weeks, the implants were divided into three groups: untreated, swabbed with saline, and swabbed with $H_2O_2$. Three implants from each group were placed to the full length in the same spot. The other three implants were placed fully into newly prepared bone. After eight weeks of healing, the animals were sacrificed. Ground sections, representing the mid-buccal-lingual plane, were prepared for histological analysis. The analysis was evaluated clinically and histometrically. Results: The untreated implants and $H_2O_2$-swabbed implants showed gingival inflammation. Only the saline-swabbed implant group showed re-osseointegration and no gingival inflammation. There was no difference in regeneration height or bone-to-implant contact between in situ implant placement and implant placement in the new bone site. Conclusions: It can be concluded that cleaning with saline may be effective in implant decontamination. After implant surface decontamination, implant installation in a previous peri-implant diseased site may not interfere with osseointegration.

치주질환에 이환된 환자에서 구치 상실 치열 수복을 위한 임플란트 수복 (Implant-Supported Fixed Prostheses for the rehabilitation of distal free end in periodontally compromised dentitions Number of fixtures affecting bone tissue change)

  • 이승원;김영수
    • Journal of Periodontal and Implant Science
    • /
    • 제35권1호
    • /
    • pp.53-63
    • /
    • 2005
  • Number of fixtures supporting prosthesis for rehabilitation of partial edentulism in distal area is an important factor in distal area to the bone tissue response around dental implant. Optimal number and optimal positioning of dental implant has leaded to the stable condition of bone tissue and successful long-term treatment outcome. This clinical and radiographic study was performed to document and evaluate the short-term result of occlusal rehabilitation by means of implant-supported fixed prostheses (ISPs) especially for partial edentulism in distal area in patients treated for advanced periodontal disease and to verify the number of fixture affecting the bone tissue response. A total of 30 consecutive patients referred because of advanced periodontal disease were included. Before the implant therapy was initiated, periodontal treatment was performed and the outcome evaluated during at least a 6-month period. An individual maintenance care program was designed for each patient. All 75 implants were placed using a 2-stage surgical approach. The patients were divided into 2 groups, in one of which two fixtures were placed and in the other of which three fixtures were placed with tripodal geometry. Following installation of the ISPs, all patients underwent a baseline examination including evaluation of i) oral hygiene, and ii) periodontal/ peri-implant conditions, and iii) radiographs. These examinations were repeated annually during the 1 or 2-year observation period. The results were as follows: 1.No single implant was lost during the observation follow-up period. 1.The percentage of plaque harboring surfaces and bleeding units upon probing were found to be low (<10%), and no soft tissue complications were recorded. 1.Two-fixture group showed bone destruction ranged from 0.0mm to 1.5mm and the mean was 0.31mm. Three-fixture group showed more bone destruction of 0.51mm. There was no statistically difference between two groups. These results suggested that the factor for success is not the number of fixture but the strict maintenance of peri-implant tissue health and initial stability of fixture.

임프란트 주위염 (PERI-IMPLANTITIS : TWO YEARS RETROSPECTIVE STUDY)

  • 전우진;김수관;하정완;김문수
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권4호
    • /
    • pp.257-260
    • /
    • 2003
  • The purpose of the present study lied in examining the incidence, treatment and failure causes of peri-implantitis by analyzing medical charts of those patients who underwent implant placement for the past 2 years. The subjects included those patients who underwent implant placement at the present hospital from January 2001 to December 2002. 3i implants were used for the analysis for the comparison of significance. A total of 301 patients were examined, among whom 102 were females and 199, males. Implants were placed in a total of 578 cases. The number of peri-implantitis was present in a total of 29 cases (21 males and 8 females), giving the incidence at 9.6%. The evidence of peri-implantitis was seen in 60 cases, which was in 10.4% of the patients. Among those cases with peri-implantitis, 28 cases (47%) underwent bone graft and 22 cases (43%) underwent maxillary sinus lift. Furthermore, 4 of these patients had systemic diseases such as diabetes or hypertension. Regular management is important for the prevention of peri-implantitis. In other words, early prevention through regular follow-ups to check the status of surrounding soft tissue would be needed to maintain implants.