• 제목/요약/키워드: perfusion method

검색결과 326건 처리시간 0.031초

공압식 심실 보조기의 동물실험 (Animal Experiment of the Pneumatic Ventrivular Assist Device)

  • 박성식;김삼현;서필원;최창휴;이상훈;이혁수;황승옥;안혁
    • Journal of Chest Surgery
    • /
    • 제32권12호
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

관동맥우회술 전후의 심근 SPECT를 이용한 수술 결과의 평가 (Evaluation of Result of Coronary Artery Bypass Graft Surgery by Using Pre and Postoperative Myocardial SPECT)

  • 이장훈;한승세
    • Journal of Chest Surgery
    • /
    • 제30권11호
    • /
    • pp.1083-1091
    • /
    • 1997
  • 영남대학교 의과대학 흉부외과학교실에서 관동맥우회술을 받은 20례의 환자에서 수술 전후에 부하$\boxUl$휴식기 심근 SPU를 실시하여 관동맥우회술 전후의 심근관류의 상태에 대한 정량적 분석을 시도하였다. 심근관류 의 정량적 분석을 위해서 수술 전후의 심근 SPU로부터 만든 극성지도를 이용하여 심근의 관류점수, 허혈 심근비, 재관류점수를 구하였다. 환자는 여자가 7명 남자가 13명이었으며 평균 연령은 56.4$\pm$9.0세 였다. 술 후 심근관류의 호전정도 평가를 위해서 수술 전후의 부하$\boxUl$휴식기 관류점수와 허혈심근비를 비교하여 보았다. 술 전 심근 SPECr에서 심근경색을 의심할 만한 지속적인 관류결손을 가지는 관동맥 영역에서도 술전후의 관류점수와 허혈심근비의 변화를 비교하여 술후 심근관류의 호전여부를 분석하였다. 관류점수는 극성지도에서 섭취정도를 10등급으로.나누고 가장 섭취정도가 높은 부위를 10점, 섭취정도가 가장 낮은 부위를 1점으로하여 각 분절면적에 점수를 곱한 간의 합을 전체 심근면적으로 나눈 값으로 하였다. 허혈심근은 극성지 도에서 섭취정도가 최고치의 60% 이하(5등급이하) 부위를 허혈부위로 판정하였다. 히혈심근비는 전\ulcorner 심근 면적에 대한 허혈부위로 판정된 심근면적의 비로 정의하였고 재관류점수는 극성지도에서 술 전 부하기 허혈 심근비를 술 후 부하기 허혈심근비로 나눈 값으로 정의하였다. 20례의 환자중 18(90%)례에서 술전에 비하여 부하1휴식기 관류점수가 모두 증가하여 술 후 심근의 관류가 증가한 것으로 판명되었다. 2례(10%)에서 판류 점수가 감소하였는데, 1례는 술후 수술과 관련된 심근경색이 의심된 예였으며 1례는 술 전 부히휴식기 관류 점수가 4.815.1로 다른 예들의 평균 관류점수 7.4$\pm$0.917.8$\pm$0.8에 비해 현저히 낮은 예였다. 허혈심근비는 17례에서 감소한 젓으로 나타났고 슬 후 수술관련 심근경색이 의심되었던 1례와 술 전 관류점수가 현저히 낮았던 1례는 술후 허혈심근비가 증가하였다. 술후 부힉휴식기 평균 관류점수(8.1$\pm$1.1/8.3$\pm$1.1)는 술전치 (7.3$\pm$1.1/7.7$\pm$1.0)에 비해 유의하게 증가하였고(P<0.01) 술 후 허혈심근비는(0.15$\pm$0.1/0.15$\pm$0.2) 술 전 치(0.32$\pm$0.2/0.23$\pm$0.2)에 비해 유의하게 감소하였다(p<0.01). 술 전 관류점수가 높을수록 술 후 재관류점수가 높은 것으로 판명되었다. 술 전 심근 SPU에서 지속적 관류결손을 가지는 관동맥 영역의 술전 부히휴식기 관류 점수는 4.3$\pm$0.514.6$\pm$0.6으로 다른 관동맥 영역의 관류점수보다 유의하게 낮았으며(P<0.01) 술 후 부하1휴식기 관류점수는 5.6$\pm$1.3/6.l$\pm$1.3으로 술 전에 비해 증가하였으나 통계학적 유의성은 없었다. 결론적으로 심근 SPECr로부터 극성지도를 만들어 술 전후의 관류점수, 허혈심근비를 정량적으로 측정하고 비교함으로써 관 동맥우회술 전 후의 심근 관류정도를 파악할 수 있었고 수술로 인한 심근관류의 향상 정도를 정량적으로 알 수 있었다.

  • PDF

우액와동맥을 통한 순행성 뇌관류법을 이용한 대동맥궁 치환의 임상성적 (Clinical Result of Aortic Arch Replacement using Antegrade Brain Perfusion Via Right Axillary Artery)

  • 김동진;나용준;정동섭;김경환
    • Journal of Chest Surgery
    • /
    • 제40권1호
    • /
    • pp.25-31
    • /
    • 2007
  • 배경: 대동맥궁 치환 수술 시 뇌 보호법은 필수불가결하며, 다양한 방법이 시도되고 있다. 이중 순행성 뇌관류법의 이용은 완전 순환 정지시간을 최소화하고 뇌관류를 가능하게 하여 중추신경계 합병증을 줄일 수 있는 방법 중의 하나이다. 본 연구의 목적은 우액와동맥을 통한 순행성 뇌관류를 이용하여 대동맥궁 치환술을 시행한 환자들의 임상 결과를 조사하는 데 있다. 대상 및 방법: 2004년 7월부터 2006년 7월까지 대동맥궁 치환 시 대동맥궁 분지의 전부 혹은 일부를 치환 후 우액와동맥을 통한 순행성 뇌관류를 시행하면서 대동맥궁 치환을 한 11명의 환자를 대상으로 하였다 남자 환자는 9명, 여자 환자는 2명이었다. 수술 당시의 진단은 A형 대동맥 박리(5/11, 45.5%), A형 벽내혈종(1/11, 9%), 대동맥류(5/11, 45.5%)였고, 평균 나이는 $60.3{\pm}12.8$세였다. 우액와동맥으로 삽관하여 심폐기 가동 후 초저체온 상태(평균 최저 비인두 체온 $11.7{\pm}1.0^{\circ}C$)에서 완전순환정지를 시행하였고, 이 기간 중 일부에서 역행성 뇌관류법을 시행하였다. 결과: 완전 순환 정지 시간은 $31.1{\pm}16.9$분이었으며 역행성 뇌관류 시간은 $21{\pm}17.8$분이었다. 뇌관류를 위한 각각의 도관과 대동맥궁 분지를 연결하는 데 걸린 평균시간은 $24.1{\pm}9.3$분이었다. 술 후 사망 환자는(0/11, 0%) 없었고, 영구적 신경학적 합병증 또한 없었다. 결론: 더 많은 수의 환자와 장기적인 성적에 대한 연구가 필요하지만 우액와동맥을 통한 순행성 뇌관류를 이용한 대동맥궁 치환술은 대동맥궁 조작을 최소화하고 색전 및 전반적인 허혈에 의한 뇌합병증을 줄일 수 있는 방법으로 생각된다.

중추신경이 온전한 쥐의 Cephalic Glucopenia가 인슐린과 글루카곤 분비에 미치는 영향 (Effects of Cephalic Glucopenia on Insulin and Glucagon Secretion in Central Nervous System-Intact Pancreas Perfused Rats)

  • Hyun Ju Choi
    • 대한의생명과학회지
    • /
    • 제6권4호
    • /
    • pp.229-235
    • /
    • 2000
  • 췌장에서 분비하는 인슐린과 글루카곤의 자극-분비 coupling 과정은 주로 혈당 농도와 중추신경계에 의하여 조절되어진다. 본 연구는 두부에 포도당이 결핍되었을 때에 중추신경계가 췌장에서 인슐린과 글루카곤이 분비되는 패턴을 Sprague-Dawley 흰쥐를 대상으로 하여 살펴보았으며, 실험 방법은 in situ 뇌-췌장 관류법을 이용하였다. 관류액은 100 mg/dL glucose와 20 mM arginine를 포함한 Krebs-Ringer 완충액 (pH 7.4)으로 하였으며, 95% $O_2$-5% $CO_2$ 가스를 계속적으로 주입시키면서 5 ml/min의 속도로 30분간 정주하였다. 대조군은 cephalic glucopenia가 일어나지 않는 군으로 하였고, 실험군은 두 군으로 나누어서 GLP1군은 cephalic glucopenia가 0분에 일어나도록 하였고, CLP2군은 16분에 일어나도록 하였다. 문맥으로 유출되는 췌장의 effluent액에서 인슐린과 글루카곤 농도를 RIA법으로 측정하였고 호르몬의 분비 속도를 산출하여 분비동태 양상을 분석하였다. 결과에서 인슐린 분비량은 GLP1군에서 가장 낮아서 cephalic glucopenia에 의하여 다소 감소하는 경향이었으나, 세 군간에 통계적으로 유의적인 차이는 없었다. 인슐린의 분비동태 양상을 살펴보면 이봉성의 정규 양상을 보였으나, GLP1군에서 첫번째 peak (4 min)가 다소 둔화되는 현상을 보였다. 글루카곤의 분비동태 양상도 이봉성의 정규 양상을 보였으며, 특히 GLP1군에 있어서 0~15분간의 글루카곤 분비량은 cephalic glucopenia에 의하여 유의성 있게 (p<0.05) 증가하였다. GLP2군에 있어서 글루카곤 분비량은 관류 후 15~30분 사이에 중가하는 경향을 볼 수 있었으나 통계적인 유의성은 없었다. 따라서 頭部의 포도당 결핍은 글루카곤의 분비를 증가시키는 것으로 나타났고, 이러한 현상은 특히 관류의 early period에서 현저하였다.

  • PDF

Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치에 관한 연구 (A Study on Cerebral Blood Flow Enhancement Device Using Blood Oxygen Level Sensor)

  • 임정현;조인희;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 춘계학술대회
    • /
    • pp.188-192
    • /
    • 2018
  • 대뇌혈류를 증가 시키는 수술은 뇌경색의 치료방법중 하나이다. 그러나 수술과 같은 침습적인 방법은 환자에게 수술 후유증 또는 부작용을 부담하게 한다. 이러한 침습적인 방법을 보완하기 위해 사람의 혈압을 이용해, 사지에 압박을 가하여 대뇌 혈류를 증가 시키는 비 침습적인 장치도 등장하였다. 그러나 속도와 정확성이 떨어지는 문제점이 제기되었다. 본 논문에서는, 정확한 측정과 측정하는 데에 걸리는 시간을 기존의 장치보다 개선하기 위해, Blood Oxygen Level Sensor를 이용하여, 양팔에 압력을 주면서 각 팔의 Perfusion Index를 측정하여, Perfusion Index가 일정 값 이하로 떨어지는 순간의 75% 압력을 팔에 가하고, 다리에는 팔에서 구해진 압력 값을 이용해 계산하여 얻은 압력을 가한다. 기존의 혈압 측정식 대뇌혈류증가 장치와 같이, 혈류량을 20%이상 증가시킬 수 있고, 또한 측정 시간도 단축한 결과를 얻어 뇌경색 환자에게 선택적으로 사용할 수 있다.

  • PDF

개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔 ($^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant)

  • 전석길;류종걸;박창권;유영선;정덕수;이종길
    • 대한핵의학회지
    • /
    • 제31권3호
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치 (Cerebral blood flow enhancement device using Blood Oxygen Level Sensor)

  • 임정현;조인희;김영길
    • 한국정보통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1083-1089
    • /
    • 2018
  • 대뇌혈류를 증가 시키는 수술은 뇌경색의 치료방법중 하나이다. 이러한 침습적인 방법을 보완하기 위해 사람의 혈압을 이용해, 사지에 압박을 가하여 대뇌 혈류를 증가 시키는 비 침습적인 장치도 등장하였다. 그러나 속도와 정확성이 떨어지는 문제점이 제기되었다. 본 논문에서는, 정확한 측정과 측정하는 데에 걸리는 시간을 기존의 장치보다 개선하기 위해, Blood Oxygen Level Sensor를 이용하여, 양팔에 압력을 주면서 각 팔의 Perfusion Index를 측정하여, Perfusion Index가 일정 값 이하로 떨어지는 순간의 75% 압력을 팔에 가하고, 다리에는 팔에서 구해진 압력 값을 이용해 계산하여 얻은 압력을 가한다. 기존의 혈압 측정식 대뇌혈류증가 장치와 같이, 혈류량을 20%이상 증가 시킬 수 있고, 또한 측정 시간도 단축한 결과를 얻어 뇌경색 환자에게 선택적으로 사용할 수 있다.

Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease

  • Min, Jee Young;Ko, Sung Min;Song, In Young;Yi, Jung Geun;Hwang, Hweung Kon;Shin, Je Kyoun
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1007-1020
    • /
    • 2018
  • Objective: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. Materials and Methods: We prospectively enrolled 281 patients (age $62.4{\pm}8.3$ years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (${\geq}50%$ diameter reduction of the left main and ${\geq}70%$ diameter reduction of other epicardial arteries) was determined. Results: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). Conclusion: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI.

Magnetic resonance imaging texture analysis for the evaluation of viable ovarian tissue in patients with ovarian endometriosis: a retrospective case-control study

  • Lee, Dayong;Lee, Hyun Jung
    • Journal of Yeungnam Medical Science
    • /
    • 제39권1호
    • /
    • pp.24-30
    • /
    • 2022
  • Background: Texture analysis has been used as a method for quantifying image properties based on textural features. The aim of the present study was to evaluate the usefulness of magnetic resonance imaging (MRI) texture analysis for the evaluation of viable ovarian tissue on the perfusion map of ovarian endometriosis. Methods: To generate a normalized perfusion map, subtracted T1-weighted imaging (T1WI), T1WI and contrast-enhanced T1W1 with sequences were performed using the same parameters in 25 patients with surgically confirmed ovarian endometriosis. Integrated density is defined as the sum of the values of the pixels in the image or selection. We investigated the parameters for texture analysis in ovarian endometriosis, including angular second moment (ASM), contrast, correlation, inverse difference moment (IDM), and entropy, which is equivalent to the product of area and mean gray value. Results: The perfusion ratio and integrated density of normal ovary were 0.52±0.05 and 238.72±136.21, respectively. Compared with the normal ovary, the affected ovary showed significant differences in total size (p<0.001), fractional area ratio (p<0.001), and perfusion ratio (p=0.010) but no significant differences in perfused tissue area (p=0.158) and integrated density (p=0.112). In comparison of parameters for texture analysis between the ovary with endometriosis and the contralateral normal ovary, ASM (p=0.004), contrast (p=0.002), IDM (p<0.001), and entropy (p=0.028) showed significant differences. A linear regression analysis revealed that fractional area had significant correlations with ASM (r2=0.211), IDM (r2=0.332), and entropy (r2=0.289). Conclusion: MRI texture analysis could be useful for the evaluation of viable ovarian tissues in patients with ovarian endometriosis.

13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가 (Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT)

  • 도용호;이홍재;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.69-75
    • /
    • 2014
  • 최근 진단 분야에서 PET/CT는 종양학 분야는 물론 심장, 신경 등 여러 가지 분야에서 널리 활용되고 있다. 그 중 심장 분야에서 $^{13}N-NH_3$ 심근 관류 PET/CT는 MBF를 이용한 절대 심근 관류의 측정이 가능하며 심근 관류 SPECT에 비하여 공간 분해능과 대조도가 우수하고 CT를 이용한 보다 정확한 감쇄 보정이 가능하다는 장점을 가지고 있다. 본 연구에서는 $^{13}N-NH_3$ PET/CT 검사 시 각 재구성 방법에 따른 정량적 심근 관류, 반정량 심근 관류 지표의 변화와 image quality의 변화를 비교하였다. 2013년 1월부터 11월까지 서울대학교병원에서 $^{13}N-NH_3$ PET/CT 검사를 시행받은 14명(평균연령 $60.24{\pm}7.21$세, 평균 몸무게 $71.54{\pm}7.43kg$, 남자 8명, 여자 6명)의 데이터를 분석하였다. 안정기, 부하기 각 10분 listmode scan의 data를 이용 동적, 정적 영상을 FBP, iterative2D, Iterative3D, TrueX의 재구성 방법을 이용하여 재구성하였다. 안정기, 부하기의 각 동적 영상을 이용하여 MBF에서 재구성 방법에 따른 RCA, LAD, LCX의 각 territory 별 심근관류와 global, reserve (stress/rest)값을 비교하였다. 또한 정적 영상을 이용 QPS에서 각 재구성 방법에 따른 extent와 TPD 를 비교하였으며 재구성 방법 별 정적 영상의 snapshoot을 제작하여 영상의 해상력과 노이즈, 판독의 용이성을 기반으로 핵의학과 판독의 5명의 blind test를 시행하였다. 각 재구성 방법에 따라 vendor에서 권고 되는 iterative2D 대비 정량적 심근 관류의 CFR은 최소 -18.68% (P=0.0002)에서 최대 7.91% (P<0.0001)의 변화를 보였으며, 반 정량적 지표들은 안정기에서 extent는 최소 -0.86%p (P=0.1953)에서 최대 5.36%p (P<0.0001), TPD는 최소 -0.57%p (P=0.2053)에서 최대 4.36%p (P<0.0001), 부하기에서 extent는 최소 1.93%p (P=0.4275)에서 최대 5.43%p (P=0.0003), TPD는 최소 1.57%p (P=0.4595)에서 3.93%p (P<0.0001) 증가된 값을 보였다. 영상의 해상력과 노이즈, 판독의 용이성을 기반으로 핵의학과 판독의 5명의 blind test에서는 FBP로 재구성된 영상이 최하위로 평가 되었으며 TrueX, iterative2D, iterative3D 순으로 평가되어 iterative3D로 재구성된 영상이 판독 시 가장 우수한 영상을 평가되었다. 각 병원은 장비에 따른 각 재구성 방법에 의한 정량적 심근 관류의 변화, 반 정략적 지표들의 과대 또는 과소평가되는 정도를 확인하고 병원 장비의 실정에 적합한 동적, 정적 재구성 방법을 확립하여 진단에 보다 유용하고 정확한 심근 관류 값을 제공하여야 할 것이다.

  • PDF