• Title/Summary/Keyword: performance type

Search Result 13,071, Processing Time 0.042 seconds

신생모험기업의 전략유형에 관한 연구

  • 백경래;박상문;배종채
    • Journal of Technology Innovation
    • /
    • v.4 no.1
    • /
    • pp.1-26
    • /
    • 1996
  • Traditional studies of new venture performance have focused on the characteristics of entrepreneurs and have shown conflicting results on the relationship between the characteristics and performance of new ventures. Recently, some researchers have broadened their search to include aspects of the industry and the strategy of new ventures. The purposes of this study are to identify wtrategic archetypes of new ventures based on the taxonomic approach and to explain the differences in new venture characteristics and performance among strategic archetypes. To find the strategic archetypes, 114 new venture CEOs from various industries were asked to describe their ventures' competitive strategy through 19 questionnaire items on competitive methods. Using factor analysis and subsequent cluster analysis, four archetypes were identified such as : versatile type, technology-driven type, market-oriented type, and cost reduction type. The results imply that there exist different types of venture strategy even among new technology-based venture firms in Korea, and show the differences in performance among strategic archetypes: market-oriented type and versatile type are better than cost reduction type in terms of growth rate and profitability. Because the venture strategy in identified as a major determinant of the venture performance in this study, the choice of venture strategy suitable for firm's industrial characteristics and internal resource bases becomes a very strategic decision for firm's sustained growth. Further studies are needed to strengthen some methodological limitations of the study.

  • PDF

An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses- (건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 -)

  • Lee, Su-In;Kim, Jeong-Gook;Kim, Seo-Hun;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

Performance Improvement of Anti-collision Algorithm for RFID Protocol and Algorithm Comparison (RFID 프로토콜의 충돌방지 알고리즘의 성능 개선과 알고리즘 비교)

  • Lim, Jung-Hyun;Kim, Ji-Yoon;Jwa, Jeong-Woo;Yang, Doo-Yeong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.6
    • /
    • pp.51-61
    • /
    • 2007
  • In this paper, Air-interface protocols of ISO 18000-6 Types and EPCglobal Classes applied to RFID system in UHF band are analyzed, and those anticollision algorithms are realized. Also, the each algorithm which improves the performance of standard protocol is proposed, and the performance is compared when clock period of link timing is a identical condition on $12.5{\mu}s$. As the result, when 500 tags exist simultaneously inside reader interrogation zone, the tag recognition performance of a standard protocol is better in preceding order of Class-1 Generation-1, Type B, Type A, Class-0 and Class-1 Generation-2. And also the performance of improved protocol is better in ascending order of Type B, Type A, Class-1 Generation-1, Class-0 and Class-1 Generation-2. Therefore, performance of tag recognition remarkably depends on the regulated clock period in the protocol and link timing between a reader and a tag.

Analysis of Performance of an Air-Type Garlic Peeler for its Optimum Design (공기식 마늘 박피기의 적정 설계를 위한 요인별 영향 분석)

  • Cho, Y.J.;Kim, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.4
    • /
    • pp.351-357
    • /
    • 1993
  • Recently, a garlic peeler with high performance is being demanded due to increase of consumption of peeled garlic. Although the air type out of various types of garlic peelers is recommended to remove effectively skin of garlic, it has an important problem of large energy consumption. This study was performed to analyze performance of an air-type garlic peeler for its optimum design. Performance indices to represent performance of garlic peeler include peeling ratio, energy efficiency and peeling performance. The factors such as aperture of nozzle, angle and position of air injection, charge rate of garlic, peeling time and so on must be considered to design optimally an air-type garlic peeler.

  • PDF

Development of Multiple Slim Type Damper System and Performance Test (다중 슬림형 감쇠장치의 개발 및 성능 실험)

  • Sung, E.H.;Kim, D.;Park, D.H.;Park, K.S.;Park, J.H.;Cho, H.J.
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.31-37
    • /
    • 2014
  • For the vibration control of residential buildings, a multiple type slim damper system is developed and dynamic performance test is performed in this study. In conventional damping systems, larger installation space is required in order to achieve acceptable seismic performance, and as a result, it is difficult to determine efficient damping capacity of the device. The proposed damping device is composed of several small slim type dampers and linkage units. It can control damping capacity easily by changing the number of the small damper. To evaluate the proposed damping device, three slim type dampers (single-type, triple-type and penta-type) are designed and manufactured in real scale. Dynamic loading tests are performed by using the three manufactured dampers. From the tests, it is shown that damping coefficient is proportional to the number of the damper combined. Thus, test results validates the practicality of the proposed slim type dampers. applying nonlinear curve fitting technique, numerical model of the dampers are developed and presented.

Performance Evaluation of Heat Sink for Cooling of LED Projector (LED 프로젝터 방열용 히트싱크의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeon, Dong-Soon;Kim, Seon-Chang;Son, Kwang-Eun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

Performance Evaluation of Side Channel Type Regenerative Blower (사이드채널형 재생블로워의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.378-383
    • /
    • 2005
  • The performances of side channel type regenerative blowers were evaluated by the blower performance test, 1-D performance prediction and CFD. The performance prediction method was modified using the results of the performance test and CFD and applied to the design of the new regenerative blowers. The major geometric parameters such as channel height, channel area and expansion angle were decided from the performance prediction method for the improved models and the predicted results were compared with CFD and experimental data. Both of the modified models showed improved efficiency at the operating condition. Especially, model3 could be possible to reduce operating rotating speed, that is benefit to noise performance, because of the high head performance at the design point. The CFD results showed that the performance of the regenerative blower was influenced by the secondary circulatory flow in the channel.

  • PDF

Study on the Improvement of Milling Recovery and Performance (V) -Experimental Study on Rice Whitening Performance of Jet-air Abrasive-Type Whitener - (도정수율(搗精收率)과 성능향상(性能向上)을 위(爲)한 연구(硏究)(V) -분풍(噴風) 연삭식(硏削式) 정미기(精米機)의 정백성능(精白性能)에 관(關)한 실험적(實驗的) 연구(硏究)-)

  • Lee, Sung Bum;Chung, Chang Joo;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.8 no.1
    • /
    • pp.17-29
    • /
    • 1983
  • The milling process is considered as causing one of the greatest grain losses among all the processes in rice post-production. Major source of grain losses in the rice milling is considered as the whitening process. This study was attempted to develop an abrasive-type whitener, the whitening chamber of which being supplied by jet-air evenly and continuously. To investigate the milling performance by the new whitener, three kind of emery-stone grit(#36, #41, and #46), and three levels of rotational speed of emery stone roller (950, 1070, and 1200 rpm) were tested. The jet-air abrasive-type whitener was also compared with the conventional abrasive-type having no jet-air blower in terms of their milling performance. In addition, the effect of different combinations of sequential uses of the abrasive- and friction-type whiteners on the milling performance was also experimentally evaluated. The results of this study are summarized as follows; 1. In general, the whitening system combined with the abrasive type whitener with jet-air supply, which was newly designed, and the existing jet-air friction type whiteners produces more milled- and head-rice by about 0.3% points and 2.8% points, respectively than the system combined with the existing abrasive type without the jet-air supply under the same operational conditions. The former also consumed less electricity by 0.024 KwH per 100kg of milled rice production and gave more milling capacity by about 35 kg/hr. As compared with the conventional whitening system consisting of jet-air friction type whiteners only, the former yielded more milled- and head-rice by 1.5% points and 4.4% points, respectively. 2. The abrasive roller having 46 grit emery was better than the roller having 36 grit in aspects of milling performance and machine efficiency, in general. 3. With regard to the effect of combination method of abrasive type and friction type whiteners, one pass in abrasive type plus three passes in friction type gave better milling performance and energy efficiency than the two passes in abrasive type plus two passes in friction type regardless of the designs of the emery stone rollers. 4. The increase in rotational speed of the emery stone roller from 950 rpm to 1200 rpm presented negative effects on milled and head-rice yields and machine efficiency, but slightly positive effect on milling capacity.

  • PDF

Comparison of detergency effectiveness by the type of household washer, detergent and soil - Focused on detergency, rinsing, fabric damage and tanglement - (가정용 세탁기, 세제 및 오염의 종류별 세탁 성능 비교 - 세탁성, 헹굼성, 섬유손상도, 엉킴도를 중심으로 -)

  • Piao, Shujing;Park, Myung-Ja
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.6
    • /
    • pp.950-960
    • /
    • 2013
  • The purpose of this research is to provide accurate information of household washers and detergents for consumers, so that help the producers who make washing machine and detergent to get basic material and also help consumers to choose washing machine. Experiment was proceed with two type of washers to compare energy consumption, washing performance, rinsing effectiveness further, damage caused by entanglement of laundry and fabric was assessed. Detergent P and T were used to compare the performance related to differences of ingredients of detergent. Soiled fabrics of EMPA 108 set were used to evaluate performance of washing by different types of contamination. A summary of experimental results are : First, for the consumption of water, drum-type washer consumed 53% less than pulsator-type washer. On the other hand, the washing time was almost similar for both these machines, but pulsator-type washer showed shorter progress, implying that power saving was more efficient in this case. Second, the drum-type washer showed better performance for contamination with all types of detergent, but the pulsator-type washer showed better rinsing performance. Third, the drum-type washer performed less data of tangle level and fabric damage. Fourth, detergent "P" exhibited better washing performance than did detergent "T", regardless of the type of soil. And with no limit of detergent variety, water-soluble protein soil showed high removal rate, liposoluble soil especially pigment was hardly removed.

Weighted fuzzy controller composed of position type fuzzy controller and velocity type fuzzy controller (위치형퍼지제어기와 속도형퍼지제어기로 구성된 퍼지 가중치 제어기)

  • 김병수;박준열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.181-183
    • /
    • 1996
  • Generally, While position type fuzzy controller has good performance in transient period, it has uniform steady state error of response. While velocity type fuzzy controller is capable of reducing steady state error of response, it is hard to develop the performance in transient period. In order to have both good performance in transient period and ability to reduce the steady state error of response, weighting fuzzy controller, which is composed of these two fuzzy controllers, is proposed. For the decision of weight to each fuzzy controller, Weighting fuzzy set is established according to the system state variables and applied to each fuzzy controller. The proposed weighted fuzzy controller has the merits of both position type fuzzy controller and velocity type fuzzy controller simultaneously.

  • PDF