• Title/Summary/Keyword: performance type

Search Result 13,071, Processing Time 0.033 seconds

Cyclic testing of weak-axis steel moment connections

  • Lee, Kangmin;Li, Rui;Jung, Heetaek;Chen, Liuyi;Oh, Kyunghwan
    • Steel and Composite Structures
    • /
    • v.15 no.5
    • /
    • pp.507-518
    • /
    • 2013
  • The seismic performance of six types of weak-axis steel moment connections was investigated through cyclic testing of six full-scale specimens. These weak-axis moment connections were the column-tree type, WUF-B type, FF-W type, WFP type, BFP-B type and DST type weak-axis connections. The testing results showed that each of these weak-axis connection types achieved excellent seismic performance, except the WFP and the WUF-B types. The WFP and WUF-B connections displayed poor seismic performance because a fracture appeared prematurely at the weld joint due to stress concentrations. The column-tree type connection showed the best seismic behavior such that the story drift ratio could reach 5%.

Performance of Cone Type Tower Fermentor for Ethanol Production (탑형발효기에 의한 에탄올 생산)

  • 서근학;송승구
    • KSBB Journal
    • /
    • v.7 no.1
    • /
    • pp.9-14
    • /
    • 1992
  • A cone type of tower fermentor loaded with flocculating Sacchromyces uvarum was used to study the fermentor performance. The performance of cone type fermentor was compared with those of other fermentors. The maximum yeast concentration in the cone type of tower fermentor was 35.9-43.0g/1.hr and the maximum ethanol productivity was 14.75g/1.hr at the dilution rate 0.26 $hr^{-1}$. The ethanol yield was 0.446-0.472g ETOH/g Glucose. It was concluded that a cone type of tower fermentor might offer better perspectives for continous etanol fermentation.

  • PDF

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

Performance Analysis of Swash Plate Type Compressor on the Inclined Angle of Swash Plate (사판의 경사각도 변화에 따른 사판식 압축기의 성능해석)

  • Lee, Geon Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.215-220
    • /
    • 2002
  • This paper describes a simulation model for estimation the performance of the swash plate type compressor for automotive air conditioning system. The model includes consideration of both the compression process and the dynamic behavior. Also, this study compares the results obtained from the performance simulation with experimental results. Further, the effects of the inclined angle of swash plate on the performance of swash plate type compressor are discussed.

  • PDF

A Study on the Ventilation Performance Estimation of Marketing Ventilation Fan Used in the Apartment House Kitchen (공동주택의 주방에서 사용되는 시판 환풍기의 환기 성능 평가에 관한 연구)

  • 송필동;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.315-320
    • /
    • 2002
  • Marketing ventilation fan 3 kinds been using in kitchen of apartment house into compensation discharge performance of contaminant measure. When propane gas burns by gas table, did waste heat into measurement compensation with carbon dioxide that it happens. In measured all type of exhaust fan, discharge performance of carbon dioxide and waste heat was high there are been much displacement. Among A, B, C three types, performance of A type exhaust fan was most superior and performance of C type exhaust fan was most poor

  • PDF

Performance Analysis of L-band Digital Aeronautical Communication Systems (L-대역 디지털 항공 통신 시스템의 수신 성능 분석)

  • Cheon, Jeong-Hyeon;Yoon, Kyung-Han;Jang, Soo-Hyun;Jung, Yun-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.2
    • /
    • pp.140-146
    • /
    • 2015
  • Due to the increase in the data traffic for the aeronautical communications, LDACS has been proposed to support the data link in the continental domain. LDACS is defined in two standards of LDACS type-1 and LDACS type-2, which are going to be selected through the intensive comparison. In this paper, we analyzed two types of standards and evaluated their performance for various channel models. Simulation results show that both LDACS type-1 and LDACS type-2 have a good performance in the en-route channel model, while they have a poor performance in the airport channel model. In the comparison results for LDACS type-1 and LDACS type-2, LDACS type-1 shows the better performance of 1dB than LDACS type-2 owing to the stronger channel coding technique.

Design and Performance Analysis of a Variable Configuration Tracked Vehicle (가변 형상 무한 궤도 차량의 성능 해석 및 설계)

  • 김한호;곽윤근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.20-27
    • /
    • 2001
  • A variable configuration tracked vehicle(VCTV) is developed to reduce turning energy and improve climbing ability for stairs. This mechanism has four track T-type frames. By changing the driving direction, each track T-type frame rotates to minimize the contact area with ground. It also has better performance than other VCTV in energy consumption of turning. Futhermore this mechanism is more stable than other VCTV on the rough terrain. When climbing stairs, each track T-type frame rotates to obtain a front attack angle and keep stability on steep stairs. The design parameters of components of track T-type frames are optimized to enhance the performance of climbing stairs. Performance indices include a stable angle, a climbing ability, a height of the vertical obstacle. In case that the overall length of the mechanism is 0.2m, it is required that the radius of the wheels should be 5mm and the length track contacted with he ground should be 0.09m to climb higher and steeper stairs.

  • PDF

Performance Test System for PSD Design (PSD 설계를 위한 성능 시험장치)

  • 고광웅;이한주;정동운;이상용;오승협
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.119-122
    • /
    • 2003
  • In this Study, the types of PSD performance test systems were reviewed. And as a results of that reviewing process, a suitable PSD performance test system type for PSD design was proposed. PSD performance test systems can be classified with pulsating methods - the pulsating whole feeding system and the pulsating working fluid. The pulsating working fluid method can be re-classified with the devices of pulsating working fluid - a piston-type pulsator and a restrict-type pulsator. The pulsating-working-fluid performance test system with restrict-type pulsator was proposed to be a suitable type for identification of main-design-parameters.

  • PDF

Simulation on Performance Characteristics of a Tip-Seal Type Scroll Compressor (팁실형 스크롤 압축기의 성능 특성에 관한 해석적 연구)

  • Youn, Young;Kim, Yong-Chan;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1306-1318
    • /
    • 2001
  • This paper presents leakage and performance characteristics of a tip-seal type scroll compressor, The performance of a scroll compressor is strongly dependent on the leak age across the compression pockets. However, literature for leakage characteristics of the tip seal type scroll compressor is very limited due to complex sealing mechanism. In the present study, a simulation study was executed to investigate the tip-seal type scroll compressor by considering leakages passing through flank and tip clearance. As a result, the leakage phenomena of the tip seal type scroll compressor as a function of discharge pressure, tip clearance, dimension of the tip seal were analyzed. Effects of leakage on the performance of the compressor were also clarified.

  • PDF

An Experimental Study on the Performance of Plastic Plate Heat Exchanger (플라스틱 판형 열교환기의 성능에 관한 실험적 연구)

  • Yoo Seong Yeon;Chung Min Ho;Kim Ki Hyung;Lee Je Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.117-124
    • /
    • 2005
  • Aluminum plate heat exchanger, rotary wheel heat exchanger, and heat pipe heat exchanger have been used (or ventilation heat recovery in the air-conditioning system. The purpose of this research is to develop high efficiency plastic plate heat exchanger which can substitute aluminum plate heat exchanger. Because thermal conductivity of plastic is quite small compared to that of aluminum, various heat transfer enhancement techniques are applied in the design of plastic plates. Five types of heat exchanger model are designed and manufactured, which are plate type, plate-fin type, turbulent promoter type, corrugate type, and dimple type. Thermal performance and pressure loss of each heat exchangers are measured in various operating conditions, and compared each other. Test results show that heat transfer performance of corrugate type, turbulent promoter type, and dimple type are increases about $43\%$, $14\%$, and $33\%$ at the equivalent fan power compared to those of plate type, respectively. On the other hand, the heat transfer performance of plate-fin type decreases $9\%$ because fins can not play their own role.