• Title/Summary/Keyword: performance tests and methods

Search Result 1,110, Processing Time 0.029 seconds

A Study on Punch Penetration Test for Performance Estimation of Tunnel Boring Machine (TBM의 굴진성능 예측을 위한 압입시험에 대한 연구)

  • Jeong, Ho-Young;Jeon, Seok-Won;Cho, Jung-Woo
    • Tunnel and Underground Space
    • /
    • v.22 no.2
    • /
    • pp.144-156
    • /
    • 2012
  • This paper discusses the methods of estimating the punch penetration indices and data analysis punch penetration test to estimate the TBM normal force and penetration rate. In punch penetration test is known as a useful test to estimate penetration rates and normal force of TBMs directly with several slope indices indicated drill-ability and brittleness of rocks. However, the standard methods and indices for punch penetration test are not suggested yet. The main purpose of punch penetration test which is prediction of normal force of TBM disc cutter when cutters excavate rock mass. In this study, the punch penetration tests were performed for 6 representative Korean rock types and variety length and diameter of rock core specimens. Among slope indices were obtained from punch penetration test, PLI and MLI which is suggested in this study show high correlation with cutter force measured by full-scale cutting test. The results show that the predicted normal force of a single disc cutter and the experimental error was 10%. Based on these results, it is concluded that punch penetration test is reliable laboratory test for estimating thrust and penetration rates of TBM.

Autothermal Reforming of Propane over Ni/CexZr1-xO2 Catalysts (Ni 담지 CexZr1-xO2 촉매상에서 프로판의 자열개질반응)

  • Kong, Jin-Hwa;Park, Nam-Cook;Kim, Young-Chul
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.47-52
    • /
    • 2013
  • In this study, the catalytic performance and characterization of $Ni/Ce_xZr_{1-x}O_2$ were investigated using an autothermal reforming (ATR) process for hydrogen production. The $Ni/Ce_xZr_{1-x}O_2$ catalysts were prepared using the following methods: the water method (CZ-W), urea water method (CZ-UW) and urea, water and ethanol method (CZ-UWA). The performance of $Ni/Ce_xZr_{1-x}O_2$ catalysts in autothermal reforming of propane for hydrogen production was studied in a fixed-bed flow reactor. Reaction tests were conducted by using a feed of $H_2O/C_3H_8/O_2$=3/1/0.37 and $300{\sim}700^{\circ}C$. The CZ-UW and CZ-UWA catalysts showed higher propane conversion and hydrogen yield than the CZ-W catalyst. The activity test confirmed that the improvement in the water-ethanol catalyst was due to the low level of carbon deposition. SEM showed that the surface carbon consisted of clusters on the used CZ-UW catalyst, which is incontrast to the nano-fiber morphology observed on the used CZ-UWA catalyst. It was found that the amount of carbon deposition depends on the preparation method. Especially the $Ni/Ce_{0.75}Zr_{0.25}O_2$ was showed higher propane conversion and hydrogen yield than the other catalysts. Also TGA showed that the resistance of carbon deposition increase to Co addition.

Quantitative Analysis of Methotrexate using Hitach-7600 P-module (Hitach-7600 P-module을 이용한 Methotrexate 정량분석 평가)

  • Kim, Min-Eui;Cha, Kyong-Ho;Kim, Seung-Hee;Kim, Nam-Joo;Chae, Hyo-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.167-172
    • /
    • 2009
  • Methotrexate (MTX) in one of the antineoplastic drug and it is known to effective to management of acute lymphoblastic leukemia in children, management of choriocarcinoma and related trophoblastic tumors in women, management of carcinomas of the breast, tongue, pharynx, and tests, maintenance of remission in leukemia and treatment of serve, debilitating psoriasis. Intermediate to high-dose methotrexate administration followed by leucovorin rescue is effective in treatment of carcinoma of the lung and osteogenic sarcoma. Intrathecal administration is effective in treating meningeal leukemia or lymphoma. There are FPIA (Fluorescence polarization immunoassay) and EMIT (Enzyme multiplied immunotechique) methods that measure for MTX. We evaluated the FPIA and EMIT methods. MTX were measured by Hitachi-7600 P-module using EMIT and FPIA using TDX in the sera 60 patients. The performance characteristics evaluated were, light influence, linearity, comparison with FPIA. Also, precision evaluated were three level controls through put following CLSI evaluation protocols (EP10-A). When the MTX value of $4.16{\pm}5.78{\mu}{\mu}mol/L$ (mean, SD) by the Hitachi-7600 P-module was compared with that of $4.05{\pm}5.47{\mu}{\mu}mol/L$ by FPIA, coefficients of correlation of 0.988 was obtained. The regression equation was Y (Hitachi-7600 P-module) = 0.9408 x (FPIA) + 0.1316 (r=0.9885, n=60). CVs of MTX measured by Hitachi 7600 P-module was 6.78% at $0.33{\mu}{\mu}mol/L$, 0.96% at $1.16{\mu}{\mu}mol/L$, and 0.96% at $8.04{\mu}{\mu}mol/L$. The precision was excellent in each group. The linearity was acceptable. We evaluated that MTX is light-sensitive on prolonged exposure to direct sunlight. Comparing with the FPIA using TDX, the Hitachi-7600 P-module using EMIT showed good coefficient of correlation and precision. Therefore the Hitachi-7600 P-module can replace the FPIA for quantitative analysis of MTX.

  • PDF

Evaluation of Short and Long-Term Modal Parameters of a Cable-Stayed Bridge Based on Operational Modal Analysis (운용모드해석에 기반한 사장교의 장단기 동특성 평가)

  • Park, Jong-Chil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.20-29
    • /
    • 2022
  • The operational modal analysis (OMA) technique, which extracts the modal parameters of a structural system using ambient vibrations, has been actively developed as a field of structural health monitoring of cable-supported bridges. In this paper, the short and long-term modal parameters of a cable-stayed bridge were evaluated using the acceleration data obtained from the two ambient vibration tests (AVTs) and three years of continuous measurements. A total of 27 vertical modes and 1 lateral mode in the range 0.1 ~ 2.5 Hz were extracted from the high-resolution AVTs which were conducted in the 6th and 19th years after its completion. Existing OMA methods such as Peak-Picking (PP), Eigensystem Realization Algorithm with Data Correlation (ERADC), Frequency Domain Decomposition (FDD) and Time Domain Decomposition (TDD) were applied for modal parameters extraction, and it was confirmed that there was no significant difference between the applied methods. From the correlation analysis between long-term natural frequencies and environmental factors, it was confirmed that temperature change is the dominant factor influencing natural frequency fluctuations. It was revealed that the decreased natural frequencies of the bridge were not due to changes in structural performance and integrity, but to the environmental effects caused by the temperature difference between the two AVTs. In addition, when the TDD technique is applied, the accuracy of extracted mode shapes is improved by adding a proposed algorithm that normalizes the sequence so that the autocorrelations at zero lag equal 1.

Strength Properties of High-Strength Concrete Exposed at High Temperature (고온을 받은 고강도 콘크리트의 강도특성)

  • 윤현도;김규용;한병찬
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.698-707
    • /
    • 2002
  • A review is presented of experimental studies on the strength performance of concrete exposed at short-term and rapid heating as in a fire and after cooling. Emphasis is placed on concretes with high original compressive strengths, that is, high-strength concrete(HSC). The compressive strength-temperature relationships from the reviewed test programs are distinguished by the test methods used in obtaining the data(unstressed, unstressed residual strength, and stressed tests) and by the aggregate types(normal or lightweight), The compressive strength properties of HSC vary differently with temperature than those of NSC. HSC have higher rates of strength loss than lower strength concrete in the temperature range of between 20$^{\circ}C$ to about 400$^{\circ}C$. These difference become less significant at temperatures above 400$^{\circ}C$ compressive strengths of HSC at 800$^{\circ}C$ decrease to about 30 % of the original room temperature strength. A comparison of lest results with current code provisions on the effects of elevated temperatures on concrete compressive strength and elastic modulus shows that the CEN Eurocodes and the CEB provisions are unconservative.

Mechanical Properties of Fiber-reinforced Cement Composites according to a Multi-walled Carbon Nanotube Dispersion Method (다중벽 탄소나노튜브의 분산방법에 따른 섬유보강 시멘트복합체의 역학적 특성)

  • Kim, Moon-Kyu;Kim, Gyu-Yong;Pyeon, Su-Jeong;Choi, Byung-Cheol;Lee, Yae-Chan;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.203-213
    • /
    • 2024
  • This study delves into the mechanical properties of fiber-reinforced cement composites(FRCC) concerning the dispersion method of multi-walled carbon nanotubes(MWCNTs). MWCNTs find utility in industrial applications, particularly in magnetic sensing and crack detection, owing to their diverse properties including heat resistance and chemical stability. However, current research endeavors are increasingly directed towards leveraging the electrical properties of MWCNTs for self-sensing and smart sensor development. Notably, achieving uniform dispersion of MWCNTs poses a challenge due to variations in researchers' skills and equipment, with excessive dispersion potentially leading to deterioration in mechanical performance. To address these challenges, this study employs ultrasonic dispersion for a defined duration along with PCE surfactant, known for its efficacy in dispersion. Test specimens of FRCC are prepared and subjected to strength, drawing, and direct tensile tests to evaluate their mechanical properties. Additionally, the influence of MWCNT dispersion efficiency on the enhancement of FRCC mechanical performance is scrutinized across different dispersion methods.

A Previous Study on Customized Visualization Expression of Personal Health Record (개인건강기록의 맞춤형 시각화 표현을 위한 선행연구)

  • Yang, Junggi;Lee, Yong-Jun;Kim, Hae-Na;Lee, YoungHo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.115-126
    • /
    • 2014
  • In order to improvement of the perceptive of health state and the motivation, this study suggests the ways and design forms which provide PHR information customizing individual attributes as well as guidelines through a decision support system and services which integrate medical information visualization. Expression methods using the color, form, position in order to visualization based on images improved performance of information awareness by changing radar chart from existing information which provide only numerical figure. The methods providing a graphic figure which seems like beads of blood which shows the result of blood tests would also arise patient's attention. They gives the patient's information which is able to compare their health status and normal status and visualizes the records as a human figure in order to perceiving their status as well. The visualization showing the position of human body figures marks in inspection elements located in position of relevant organs. The method also uses icons represent examination results so they improve attention of the results and shorten recognize times.

Comparison of medical history based diagnosis and urine test using ultra-performance liquid chromatography-tandem mass spectrometry in drug overdose (약물중독 환자에서 병력 기반 진단과 요 고성능 액체색층분석 탄뎀 질량 분광분석의 비교)

  • Lee, Ja-Young;Cha, Kyungman;Jeong, Won Jung;Kim, Hyung Min;So, Byung Hak
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: In patients with acute drug overdose, identification of drugs ingested is crucial to make a precise diagnosis. In most cases, the diagnoses are made on the medical history and physical examination findings. This study was undertaken to determine the concordance of diagnosis made on the basis of patient history by comparing it with urine toxicology analysis. Methods: This was a retrospective study of drug intoxicated patients over 18 years old who presented to the emergency center from 2017 to 2019. Specimens from urine were tested using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-TMS). The test results were compared with information obtained from patients. Diagnostic concordances for drug detection in intoxicated patients were calculated. Logistic regression analysis was used to examine the association between clinical characteristics and diagnostic discrepancy. Results: Totally, 370 patients were included in the analysis. Overall, 66 types of drugs were detected by UPLC-TMS. The drugs detected most frequently were zolpidem (104, 27.8%), citalopram (70, 18.7%), and paracetamol (66, 17.6%). The mean diagnostic concordance of patients was 52.7%. There were statistically significant diagnostic discrepancies in patients with underlying depression and patients intoxicated with multiple types of drugs. Conclusion: In ED patients with acute drug overdose, the diagnoses made on history alone were often inaccurate. It is essential to perform urine toxicology tests such as UPLC-TMS as a confirmatory instrument to improve accuracy in evaluating patients with drug intoxication.

The Effects of Weighted Vest During Task-Oriented Training on Gross Motor Performance and Balance Abilities of Children With Spastic Diplegia : A Randomized Clinical Trial Study (경직형 양마비 아동의 과제지향훈련 시 무게조끼 적용이 대동작 수행력과 균형 능력에 미치는 영향: 무작위배정 위약비교 연구)

  • Kwon, Hae-Yeon
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.15 no.2
    • /
    • pp.46-65
    • /
    • 2017
  • Objective : The purpose of this research is to find clinical effects of application of weighted vest during task-oriented training focused on gross motor performance and balance abilities of children with spastic diplegia. Methods : 34 subjects were divided by simple random sampling into two groups; experimental group (male : 9, female : 8, average age : 8.12) and placebo group (male : 9, female : 9, average age : 7.53). Both two groups underwent to 40 minute intervention, twice a week for 12 weeks. The intervention was task-oriented training focused on facilitating closed kinematic chain and multi-joint functional movement pattern. During the training, the experimental group received loaded-resistance weighted vest and placebo group also received weighted vest but without loaded-resistance. Participants in both groups underwent 8 to 10 reps of the task-oriented training and there were 3 minutes break time between tasks. There were pre-test of gross motor performance and balance abilities, and two times of post-tests were performed upon 6 weeks and 12 weeks after the intervention completed. And in final, an additional follow-up test was performed 12 weeks after the evaluation was finished in order to find any difference between the two groups over time. Results : There was significant difference in Gross Motor Performance Measure (GMPM) between two groups. It is found that average score of the experimental group increased more than the placebo group after 6 weeks and 12 weeks intervention (p<.05). There was significant difference in Pediatric Berg's Balance Scale (PBS) between two groups. It is found that average score of the experimental group increased more than the placebo group after 6 weeks and 12 weeks intervention (p<.05). Conclusion : Based on the results in this study, it is proposed that application of weighted vest into task-oriented training to facilitating closed kinematic chain and multi-joint movement can improve gross motor performance and balance abilities of children with cerebral palsy.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.