• Title/Summary/Keyword: performance test criteria

Search Result 706, Processing Time 0.03 seconds

Knowledge graph-based knowledge map for efficient expression and inference of associated knowledge (연관지식의 효율적인 표현 및 추론이 가능한 지식그래프 기반 지식지도)

  • Yoo, Keedong
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.4
    • /
    • pp.49-71
    • /
    • 2021
  • Users who intend to utilize knowledge to actively solve given problems proceed their jobs with cross- and sequential exploration of associated knowledge related each other in terms of certain criteria, such as content relevance. A knowledge map is the diagram or taxonomy overviewing status of currently managed knowledge in a knowledge-base, and supports users' knowledge exploration based on certain relationships between knowledge. A knowledge map, therefore, must be expressed in a networked form by linking related knowledge based on certain types of relationships, and should be implemented by deploying proper technologies or tools specialized in defining and inferring them. To meet this end, this study suggests a methodology for developing the knowledge graph-based knowledge map using the Graph DB known to exhibit proper functionality in expressing and inferring relationships between entities and their relationships stored in a knowledge-base. Procedures of the proposed methodology are modeling graph data, creating nodes, properties, relationships, and composing knowledge networks by combining identified links between knowledge. Among various Graph DBs, the Neo4j is used in this study for its high credibility and applicability through wide and various application cases. To examine the validity of the proposed methodology, a knowledge graph-based knowledge map is implemented deploying the Graph DB, and a performance comparison test is performed, by applying previous research's data to check whether this study's knowledge map can yield the same level of performance as the previous one did. Previous research's case is concerned with building a process-based knowledge map using the ontology technology, which identifies links between related knowledge based on the sequences of tasks producing or being activated by knowledge. In other words, since a task not only is activated by knowledge as an input but also produces knowledge as an output, input and output knowledge are linked as a flow by the task. Also since a business process is composed of affiliated tasks to fulfill the purpose of the process, the knowledge networks within a business process can be concluded by the sequences of the tasks composing the process. Therefore, using the Neo4j, considered process, task, and knowledge as well as the relationships among them are defined as nodes and relationships so that knowledge links can be identified based on the sequences of tasks. The resultant knowledge network by aggregating identified knowledge links is the knowledge map equipping functionality as a knowledge graph, and therefore its performance needs to be tested whether it meets the level of previous research's validation results. The performance test examines two aspects, the correctness of knowledge links and the possibility of inferring new types of knowledge: the former is examined using 7 questions, and the latter is checked by extracting two new-typed knowledge. As a result, the knowledge map constructed through the proposed methodology has showed the same level of performance as the previous one, and processed knowledge definition as well as knowledge relationship inference in a more efficient manner. Furthermore, comparing to the previous research's ontology-based approach, this study's Graph DB-based approach has also showed more beneficial functionality in intensively managing only the knowledge of interest, dynamically defining knowledge and relationships by reflecting various meanings from situations to purposes, agilely inferring knowledge and relationships through Cypher-based query, and easily creating a new relationship by aggregating existing ones, etc. This study's artifacts can be applied to implement the user-friendly function of knowledge exploration reflecting user's cognitive process toward associated knowledge, and can further underpin the development of an intelligent knowledge-base expanding autonomously through the discovery of new knowledge and their relationships by inference. This study, moreover than these, has an instant effect on implementing the networked knowledge map essential to satisfying contemporary users eagerly excavating the way to find proper knowledge to use.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Robust Reference Intervals for Serum Kappa and Lambda Free Light Chains from a Multi Centre Study Population from Hyderabad, India: Myeloma Diagnostic Implications

  • Mohammed, Noorjahan;Chandran, Priscilla Abraham;Kandregula, Madhavi;Mattaparthi, Ratna Deepika;Gundeti, Sadasivudu;Volturi, Jyotsna;Darapuneni, Radhika;Raju, Sree Bhushan;Dattatreya, Palanki Satya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2605-2610
    • /
    • 2016
  • The International Myeloma Working Group considers the serum free light chain (SFLC) assay to be an adjunct to traditional tests. Apart from the FLC ratio, the absolute values of individual free light chains also are gaining importance as they appear to be more relevant in certain clinical settings. Automated assays are available for their determination. As laboratories put new test systems into use catering to different disease populations, they are required by accreditation and certification bodies to verify or establish performance specifications, including reference intervals (RIs) representative of their population. Our aim was to establish local RIs for SFLC in a multicentre representative healthy population using a robust method. There was no significant relationship between SFLC levels and age, gender and creatinine levels. The 95% RI for ${\kappa}SFLC$ was 4.81 to 33.86mg/L, for ${\lambda}$ SFLC was 5.19 to 23.67mg/L and for ${\kappa}/{\lambda}SFLC$ was 0.36 to 2.33, significantly higher than the values given by the manufacturer. The ${\kappa}/{\lambda}$ SFLC ratio at 2.23, covering 100% of the data, showed 72% sensitivity (95% CI=39.0 - 94.0), 100% specificity (95% CI=71.5 - 100.0), 100% PPV (95% CI=21.5 - 100.0), 95% NPV (95% CI=75.4 - 99.9), and 79% accuracy (95% CI=56.0 - 93.0). In the patient group, kit RI for ${\kappa}/{\lambda}$ SFLC ratio classified 45.5% (n=5) as positive vs 9.1% (n=1) positive by the study RI, while the kit RI for kappa FLC classified 90.9% (n=10) as positive vs 54.5% (n=6), indicating increased probability of false positive test results with the kit RI when applied to our patient population. Appropriate and specific reference intervals and criteria values result in fewer false-positive and false-negative results which means fewer wrong or missed diagnoses.

BORDERLINE DISORDER OF CHILDHOOD : 8 CASES (아동기 경계선 장애 : 8증례)

  • Hong, Kang-E;Lee, Jeong-Seop;Shin, Min-Sup
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.6 no.1
    • /
    • pp.3-17
    • /
    • 1995
  • The so-called borderline children are characterised by disturbances in the sense of reality and interpersonal relationships, lack of control, fluctuation of functioning, uneven development and excessive anxiety. But the concept of borderline disorder of childhood is very difficult to define and diagnose in current classification system. The present study adapted the consensus symptoms in borderline children by Bemporad and Vera eight cases aged 7-11 were examined in 37 variables. Results are as follows 1) All subjects are boys and girl hardly be diagnosis n current diagnostic system and have many concurrent diagnoses. Common chief complaints in the sense of reality. 2) In KEDI-WISC test, the borderline children showed average intelligence, but performance IQ tends to be higher than verbal IQ. In Rorscharch test, they showed high thought disorder index, emotional instabilities and aggressive impulses. The results of TOVA suggested attentional deficit in half of the subjects. The organicity is not prominent. 3) Many of the borderline children were unwanted baby. Although primary care takers of all the subjects were their mothers there were moderate problems in caring attitude of their children and marital relationship with their husband. Sccioeconomic status was generally below middle class. Most of all subjects have delayed language development, but have overcome subsequently. Many subjects were rejected by peers because of their aggression. 4) The first visit of the subjects was about 6 years of age. Average duration of treatment was 2 years. All of them were treated in the outpatient basis except one. The effect of pharmacotherapy was doubtful and the necessity of long term play therapy was suggested. Although there were many limitations of method in present study, it was suggested that further research is needed for diagnostic criteria, epidemiology and treatment.

  • PDF

Bioequivalence of Boryung Torsemide Tablet to Torem Tablet (Torasemide 10 mg) by High Performance Liquid Chromatography/UV Detector

  • Cho, Hea-Young;Kang, Hyun-Ah;Park, Chan-Ho;Kim, Se-Mi;Kim, Dong-Ho;Park, Sun-Ae;Kim, Kyung-Ran;Hur, Hyeon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two torasemide tablets, Torem tablet (Roche Korea Co., Ltd., Korea, reference drug) and Boryung Torsemide tablet (Boryung Pharmaceutical Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (furosemide) to human serum, serum samples were extracted using 5 mL of ethyl acetate. Compounds were analyzed by reverse-phase HPLC method with UV detection. This method showed linear response over the concentration range of 0.05 ug/mL with correlation coefficient of 0.999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ug/mL which was sensitive enough for pharmacokinetic studies. Twenty-eight healthy male Korean volunteers received each medicine at the torasemide dose of 20 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of torasemide were monitored by an HPLC-UV for over a period of 12 hr after the administration. $AUC_{t}$(the area under the serum concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum serum drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{t}$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_{t}$ ratio and the $C_{max}$ ratio for Boryung Torsemide/Torem were log 0.97-10g 1.03 and log 0.93log 1.12, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Boryung Torsemide tablet and Torem tablet are bioequivalent.

Development of Concrete and Evaluation of Properties of Combined Steel making Slag Aggregates for Offshore Structure Production(II) (해양구조물 제조를 위한 제강슬래그 골재 조합별 물성평가 및 콘크리트 개발(II))

  • Jung, Won-Kyong;Kim, Hyun-Seok;Park, Dong-Cheon;Cho, Bong-Suk
    • Resources Recycling
    • /
    • v.25 no.2
    • /
    • pp.60-68
    • /
    • 2016
  • In this study, earlier analyzed tetrapod, one of an original group of offshore constructions studied for manufacturability of the concrete using the properties of steel making slag aggregate. steel making slag aggregate assessment, RCS and Blast Furnace Slag : the 20 mm air-cooled slag and combinations by 50 %, aggregate properties on the most appropriate for the properties of recycled aggregate concrete optimal mix, and assessing it. Properties of concrete used to be derived are judged as to bury the studies show that the hollowing-out of the RCS, plastic sole use is in the workability of the aggregate, plastic in the 20 mm slag also assessed to be a slight disadvantage, but RCS by mixing air-cooled coarse and 50 percent to 20 percent 50 mm. Thus, steel making slag marine structures using recycled aggregate, in rapid chilled slag or air-cooled slag. The sole use of the aggregate them than to combine the aggregate of concrete. After they satisfy the quality standard quality shall be used will aggregate steel making slag who meet the criteria concrete manufacturing in general or par with the aggregate of concrete. Performance was assessed as to develop a more than that.

Analysis of a Comparability Test between LX Detergent Cleaning Solution and OC Detergent Cleaning Solution Using OC Sensor PLEDIA (OC Sensor PLEDIA를 이용한 LX Detergent Cleaning Solution과 OC Detergent Cleaning Solution의 동등성 평가)

  • Cha, Kyung Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.19-31
    • /
    • 2021
  • This study aimed at comparing the performance of imported LX detergent cleaning solution (LX-CS) and the self-manufactured OC cleaning solution (OC-CS), based on functional and quantitative analysis. The functional analysis was carried out using apparent diffusion coefficient (ADC) values. For quantitative analysis, precision, linearity, and carry-over rates were measured with commercial control materials according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Using OC-Sensor PLEDIA (Eiken Chemical, Japan), the ADC value of all cuvettes satisfied the acceptance criteria. For quantitative analysis, precision was less than 5.0% for the two products, and carry-over rates were less than ±1.00%. The linearity slopes and r2 values were 1.0017 and 0.9982 in the LX-CS, and 0.9924 and 0.9996 in the OC-CS, respectively. The correlation coefficient (r) was found to be 0.9997. Also, the percent difference in correlation with 40 artificial-stool specimens was less than 10% and the p-value was less than 0.1. The result of standard deviation ratio (D: ±1 SD ratio) was similar for both products. In conclusion, the functional and quantitative analyses of the two products were compared and showed similar results. In the future, the self-manufactured OC-CS will be able to provide a much more stable and faster supply than the imported LX-CS.

A Study on Quality Improvement and Verification of Recycled Coarse Aggregate for Concrete Using an Impact Crusher with Radial Rotation (방사형 회전이 추가된 임팩트 크러셔를 이용한 콘크리트용 순환굵은골재 품질향상 및 검증 연구)

  • Jeon, Duk-Woo;Kim, Yong-Seong;Jeon, Chan-Soo;Choi, Won-Young;Cho, Won-Ig
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.133-142
    • /
    • 2022
  • The purpose of this study is to develop an impact crusher with a radial rotating plate installed at the bottom, which is a shock absorber that can produce high-quality recycled coarse aggregate for concrete and to verify the effect of improving the quality performance of recycled coarse aggregate and its applicability through concrete tests. As a result, it showed improved quality in all items such as absolute dry density, absorption rate, abrasion resistance, Particle shape judgment rate, amount lost in the 0.08 mm sieve passing test, alkali aggregate reaction, clay mass, stability, and impurity content, and it was found to meet the criteria of recycled aggregate quality standards. In addition, the air volume and slump of concrete to which recycled coarse aggregate is applied meet all domestic standards. According to the test results of the compressive strength characteristics by age of concrete according to the mixing ratio of the recycled coarse aggregate, it was confirmed that the mixing ratio of the recycled coarse aggregate was applicable up to 60 %.

Exposure Assessment of Heavy Metals Migrated from Glassware on the Korean Market (국내 유통 식품용 유리제의 중금속 노출 평가)

  • Kim, Eunbee;Hwang, Joung Boon;Lee, Jung Eun;Choi, Jae Chun;Park, Se-Jong;Lee, Jong Kwon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2022
  • The purpose of our study was to investigate the migration level of lead (Pb), cadmium (Cd), and barium (Ba) from glassware into a food simulant and to evaluate the exposure of each element. The test articles were glassware, including tableware, pots, and other containers. Pb, Cd, and Ba were analysed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The analytical performance of the method was validated in terms of its linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. The monitoring was performed for 110 samples such as glass cups, containers, pots, and bottles. a food simulant. Migration test was conducted at 25? for 24 hours in a dark place using 4% acetic acid as a food simulant. Based on the data; exposure assessment was carried out to compare the estimated daily intake (EDI) to the human safety criteria. The risk levels of Pb and Ba determined in this study were approximately 1.9% and 0.3% of the provisional tolerable weekly intake (PTWI) and tolerable daily intake (TDI) value, respectively, thereby indicating a low exposure to the population.