• Title/Summary/Keyword: performance test criteria

Search Result 706, Processing Time 0.026 seconds

A Study on the Injury Criteria of the Occupant Protection Performance of Crush Cushions (충격흡수시설의 탑승자보호 성능평가 기준에 관한 연구)

  • Lim, Jae-Moon;Jung, Geun-Seup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • The performance of crash cushion systems is certified through the full scale crash tests by the standard for installation and maintenance guidelines for roadside safety appurtenance. The impact severities of impacting vehicles in collision with crash cushion systems are rated by indices THIV and PHD. Crash test results are considered to study the performance of three crash cushion systems. In case of the frontal impact or the offset frontal impact, the results show that THIV values of three systems are very close to the threshold limit for the occupant protection. Also, the results show that PHD would be improper for the occupant protection performance index. In order to improve the occupant protection performance of crash cushions, ASI needs to be included in the impact severity index.

Experimental Performance Estimate of a 40m PSC I Girder for Railway Bridges (40m PSC I형 철도교의 동적 성능 평가)

  • Yeo, Inho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.5
    • /
    • pp.394-401
    • /
    • 2013
  • Here we report the results of an experimental laboratory test to verify the applicability to railway bridges of a PSC I girder of which the upper flange thickness was increased to improve sectional performance. The thicker this flange is, the further upward the neutral axis is moved. If in this way the span length can be increased to 40m long, the bridge may be constructed with four girders instead of five. Therefore, construction cost could be lowered by reducing the weight of the long span structure due to increased sectional efficiency. It was also necessary to be certain that the dynamic performance of this relatively flexible structure would be applicable to railway bridges. Therefore numerical analysis, as well as static and dynamic tests, was carried out for a full-size PSC I girder. Based on these results, it was verified that the performance of the PSC I railway bridge satisfied the performance criteria of the design code.

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Development of Prototype Electronic Dosimeter using the Silicon PIN Diode Detector (실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.197-205
    • /
    • 2000
  • A prototype electronic dosimeter(PED) adopting a silicon PIN diode detector as a radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this PED has been performance-tested by using a reference photon radiation field. As a result in a electronic performance test, radiation signals from a detector were well observed in the signal processing circuit. The radiation detection sensitivity of this PED after several test-irradiations to $^{137}Cs$ gamma radiation source appeared to be 1.85 cps/$Gy{\cdot}h^{-1}$ with 19.3% of the coefficient of variation, which satisfied the performance criteria for the active personnel radiation monitor. Further improvement of the electronic circuit and operating program will enable the PED to be used in personal monitoring purpose.

  • PDF

A Study on the Development and Application of Performance Evaluation Criteria for Co-op Programs in Universities: Focused on the Case of KOREATECH (대학 장기현장실습 프로그램의 성과평가지표 개발 및 적용에 관한 연구 : 한국기술교육대학교의 사례)

  • Oh, Chang-Heon;Om, Kiyong
    • Korean Management Science Review
    • /
    • v.32 no.4
    • /
    • pp.155-173
    • /
    • 2015
  • Koreatech has adopted a long-term co-op program called IPP (Industry Professional Practice) to address problems in higher education of Korea since 2012, but it was anticipated to face many difficulties in implementing the program due to lack of relevant experiences in Korea. In this regard, a performance evaluation scheme was urgently required to judge the effectiveness of the Co-op program and improve the operational efficiency at the same time. This study aimed to develop comprehensive performance evaluation criteria for the co-op programs on the basis of Kirkpatrick's four-level performance evaluation model for training programs, and apply it to a real Co-op operation to test its feasibility. For this purpose, thorough review on the training program evaluation literature and in-depth analyses of overseas cases of co-op performance evaluation were conducted. Then, a set of Co-op performance evaluation criteria was developed and applied to the Koreatech's Co-op operation in 2013. Two Co-op student questionnaire surveys were administered before and after Co-op terms to measure students' reactions to the Co-op program (Level 1) and changes in participating students' attitudes and competencies (Level 2). In addition, employment rates of Co-op participating and non-participating students were compared (Level 4). The analysis findings showed that participating students were quite satisfied with their jobs and companies, and the Co-op program was effective to a certain degree at enhancing non-major competencies and attitudes to occupation of students. Together, the employment rate of Co-op participants, particularly in small- and medium-sized companies, grew significantly in comparison with that of non-participants. In the last part, several directions for improving the effectiveness of the Co-op programs were discussed.

Perception and Work Performance of Patient Safety among Nurses Working in Long-term Care Hospitals (요양병원 간호사의 환자안전인식도와 업무수행도 비교)

  • Moon, Ok Nyun;Kim, Young Im;Geun, Hyo Geun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.25 no.2
    • /
    • pp.118-129
    • /
    • 2016
  • Purpose: This study aims to examine the levels of the perception and work performance of patient safety based on the healthcare accreditation criteria among long-term care hospital nurses. Methods: A cross-sectional study was performed using questionnaires. Out of 205 criteria, 39 items relevant to patient safety were selectively adapted for this study. Data were analyzed with descriptive statistics, t-test, ANOVA, and Pearson correlation coefficient. Results: The mean scores of perception and work performance were 4.36 and 4.24 out of 5, respectively, and the difference between them was significantly different (t=5.78, p<.001). The two variables were both significantly higher among those nurses who were older, married, head nurses, had many nursing experiences, and aware of Healthcare Accreditation than the other nurses. Positive correlations were observed between perception and work performance in all three sub-systems. The relations between these two in the patient care system was the most highly correlated (r=.894, p<.001). The lowest scores of perception and work performances were fire-related criteria (i.e., reporting). Conclusion: Overall, subject's perception proves to be higher than their work performance. It is necessary to develop some viable environment and training programs to enhance their work performance up to the level of their perception of patient safety.

Development of Reliability Acceptance Sampling Plan for the Case where the Degradation Quantity of the Performance Characteristic follows Weibull Distribution based on the Accelerated Degradation Test (성능특성치의 열화가 와이블 분포를 따를 때 가속열화시험을 활용한 신뢰성 샘플링검사계획의 개발)

  • Lim, Heonsang;Park, Jaehun;Sung, Si-Il
    • Journal of Applied Reliability
    • /
    • v.18 no.2
    • /
    • pp.122-129
    • /
    • 2018
  • Purpose: This article develops an optimal reliability acceptance sampling plan for the case where the degradation quantity of the performance characteristic follows Weibull distribution. Method: For developing reliability acceptance sampling plans, the sample size and the acceptance constant are determined based on the accelerated characteristic of the test condition and the product. Results: The sample size and the acceptance constant are provided such that the constraints of the producer and the consumer risks are satisfied. Conclusion: Reliability acceptance sampling plans based on the accelerated degradation test method can be used for the quality control within a resonable amount of cost and time. In this article. an optimal reliability sampling plans are newly developed for this purpose.

A Study on Suitable Condition of Accelerated Aging Test and Evaluation Criteria of Data Stability for Archival Performance Analysis of BD-R media (BD-R 장기보존 특성 평가를 위한 가속 열화 실험 조건과 안정성 평가 기준에 관한 연구)

  • Lee, Kwan-Yong;Park, Sun-Joo;Kim, Do-Hyun;Jo, Yi-Hyung;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • The Blu-ray Disc Recordable(BD-R) is one of strong candidates for archival application among optical media formats, because of its large capability. However, the well-defined accelerated aging test conditions and evaluation criteria have not yet been fully confirmed for BD-R. In this study, the data stability and degradation aspect of BD-R were analyzed by the random-symbol error rate(R-SER) measurement after the accelerated aging test. And a reasonable test condition of accelerated aging for BD-R and the appropriate evaluation criterion using R-SER measurement were discussed.

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux (건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구)

  • Park, Youngju;Kim, Youngtak
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.

The Effects of Constructivist Instruction on Children's Writing Performance (구성주의적 작문 수업이 아동의 작문수행에 미치는 효과)

  • Kang, Byeong Jae;Kim, Hye Jin
    • Korean Journal of Child Studies
    • /
    • v.21 no.2
    • /
    • pp.83-97
    • /
    • 2000
  • Ninety 6th graders were randomly assigned to an experimental or a control group in this 5 week study of the effects of constructivist instruction on writing performance. After the writing pre-test, the experimental group was treated with constructivist instruction while the control group was treated with a tradition procedure based on Joyce and Weil's(1992) basic exercise model Instruction consisted of ten 40-minute sessions. The effectiveness of the constructivist instruction was tested by post-and retention-tests. Two raters scored the children's writing by the analytical scale of Jin-Suk Won(1994). Results were analyzed by t-test. The writing performance and the retention scores of the experimental group were higher than that of the control group. The results of the sub-criteria scores showed significant effects on children's understanding of contents and constructive performance.

  • PDF