• Title/Summary/Keyword: performance objective

Search Result 5,782, Processing Time 0.036 seconds

A Study on Automatic Coregistration and Band Selection of Hyperion Hyperspectral Images for Change Detection (변화탐지를 위한 Hyperion 초분광 영상의 자동 기하보정과 밴드선택에 관한 연구)

  • Kim, Dae-Sung;Kim, Yong-Il;Eo, Yang-Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.5
    • /
    • pp.383-392
    • /
    • 2007
  • This study focuses on co-registration and band selection, which are one of the pre-processing steps to apply the change detection technique using hyperspectral images. We carried out automatic co-registration by using the SIFT algorithm which performance was already established in the computer vision fields, and selected the bands fur change detection by estimating the noise of image through the PIFs reflecting the radiometric consistency. The EM algorithm was also applied to select the band objectively. Hyperion images were used for the proposed techniques, and non-calibrated bands and striping noises contained in Hyperion image were removed. Throughout the results, we could develop the reliable co-registration procedure which coincided with accuracy within 0.2 pixels (RMSE) for change detection, and verified that band selection depending on the visual inspection could be objective by extracting the PIFs.

Systematic Determination of Empirical Parameters Used in Helicopter Conceptual Design (헬리콥터 개념설계에 사용하는 경험적파라메터의 체계적인 결정기법)

  • Kim, Won-Jin;Chae, Sang-Hyun;Oh, Se-Jong;Kim, Seung-Bum;Ahn, Iee-Ki;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.8
    • /
    • pp.703-710
    • /
    • 2012
  • At the stage of conceptual design of a helicopter, it is a general way using low fidelity analysis methods because of a large number of design calculations and trade-off studies. Determination of empirical parameters used in analysis codes for more practical design, depends on an user's design experiences, which effects on the accuracy and the fidelity of conceptual design results. Thus, more precise and logical method should be required to determine the empirical parameters used in the conceptual design of a helicopter. The present method is to be used not only in verifying the empirical parameters generated by design requirements, but also regenerate them if they contain any errors. Empirical parameters produced by present method were used to design a helicopter with a payload objective and performance constraints of an operating helicopter. As a result, weights and geometries of designed helicopter matched the target value within 5% significance level, proving that the suggested parameter generating method can be useful in the conceptual design of a helicopter.

Association between one-leg standing ability and postural control in persons with chronic stroke

  • Choi, Bora;Hwang, Sujin;Kim, Eunjeong
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.3
    • /
    • pp.165-170
    • /
    • 2020
  • Objective: To investigate the association between one-leg standing ability and postural control for chronic hemiparetic stroke. Design: Cross-sectional study. Methods: Forty individuals who had a first diagnosis of stroke with hemiparesis before six months and over had participated in this study. To analyze the relationship between one-leg standing ability and postural control in the participants, six clinical measurement tools were used for assessment, including the Timed-Up-and-Go (TUG) test, Berg Balance Scale (BBS), Dynamic Gait Index (DGI), Fugl-Meyer Assessment (FMA), 5 times sit-to-stand (5TSTS) and one-leg standing (OLS). Results: After analyzation, the OLS scores in the more-affected side showed significant positive correlations with BBS scores (r=0.469, p<0.01), DGI scores (r=0.459, p<0.01).and FMA scores (r=0.425, p<0.01). The OLS scores in the more-affected side showed significant negative correlations with TUG score (r=-0.351, p<0.05). The OLS score in the less-affected side showed significant positive correlations with BBS scores (r=0.485, p<0.01), DGI scores (r=0.488, p<0.01) and FMA score (r=0.352, p<0.05). The OLS scores in the less-affected side showed significant negative correlation with TUG scores (r=-0.392, p<0.05) and 5TSTS (r= -0.430, p<0.01). The OLS scores in the more-affected side showed significant positive correlations with the OLS scores in less-affected side (r=0.712, p<0.01). Conclusions: The results of the study suggest that the OLS time may be moderately correlated with static and dynamic postural stabilities and motor recovery following stroke. This study also suggests that the OLS test is as a simple clinical tool for predicting postural control performance for individuals with chronic hemiparetic stroke.

Evaluation of Mechanical Characteristics of Castor Oil Based Bio-Polymer Concretes for Ultra Thin Overlays (피마자유를 이용한 초박층 덧씌우기용 바이오 폴리머 콘크리트의 역학적 특성 평가)

  • Park, Hee Mun;Choi, Ji Young;Kim, Tae Woo;Ahn, Young Jun;Le, Van Phuc
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.39-45
    • /
    • 2013
  • PURPOSES : The objective of this study is to evaluate the mechanical characteristics of castor oil based bio-polymer concrete for use of ultra thin overlays. METHODS : To evaluate the mechanical properties of bio-polymer concrete, the various laboratory tests including compressive, tensile, and flexural strength, and elongation tests were conducted on bio-polymer concrete specimens in this study. The mechanical characteristics of bio-polymer concretes were examined by changing the content of hardener and polymer binder to determine the optimum content for ultra-thin overlays. The bio-polymer concrete developed in this study was used for field trial test of the ultra-thin bridge deck pavement for verifying the workability and monitoring the long-term performance of materials. RESULTS : Test results showed that tensile and the flexural strength of bio-polymer concretes increase and the elongation of bio-polymer concrete decreases with increase of binder content. A field adhesive strength tests conducted on bridge deck pavement indicates the bio-polymer concrete has more than 2MPa of adhesive strength satisfy with the design criteria. CONCLUSIONS : The bio-polymer concrete with more than 20% content of castor oil was developed for ultra-thin overlays in this study. It is found from this study that the 35% of hardener content is most appropriate for maintaining the strength characteristics and flexibility.

The effect of anti-stripping on asphalt mixtures depending on the types of anti-stripping agents (박리방지제에 따른 아스팔트 혼합물의 박리방지 특성 연구)

  • Kim, Won Jae;Tran Van, Phuc;Do Thanh, Chung;Park, Chang Kyu;Lee, Hyun Jong
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.127-135
    • /
    • 2017
  • PURPOSES: The objective of this study is to evaluate the effect of anti-stripping on asphalt mixtures constituting anti-stripping agents. METHODS : Based on the literature review, asphalt mixture added with anti-stripping agents was prepared, and these asphalt mixtures were evaluated for anti-stripping properties for each anti-stripping agent through various lab tests, namely, tensile strength ratio (TSR), dynamic immersion test, uniaxial compression test, and indirect tensile strength test (IDT). The liquid anti-stripping agents used in the lab test were premixed with each asphalt binder (PG 64-22, PG 76-22) before being mixed with the aggregate. RESULTS :The result of the TSR test revealed that the effect of anti-stripping was highest when hydrated lime and liquid anti-stripping agent W were added. The correlation coefficient $R^2$ between the TSR result and cohesion ratio is 0.99, which indicates that the sensitivity of the TSR to moisture damage is reliable from the mechanical point of view. The covering ratio of the asphalt binder to the liquid anti-stripping agent W was determined to be higher than that to the other liquid anti-stripping agents. CONCLUSIONS :It is considered that the improved moisture resistance of asphalt mixture as a result of the use of anti-stripping agents can reduce the incidence of various pavement damages such as portholes caused by stripping, and the performance life of the asphalt road pavement can be prolonged.

Test Rig Development for Identification of Rotordynamic Force Coefficients of Squeeze Film Dampers in Automotive Turbocharger Bearing Systems (자동차 터보차저 베어링 시스템에 적용되는 스퀴즈 필름 댐퍼의 동적계수 측정을 위한 실험장치 개발)

  • Hwang, Jisu;Ryu, Keun;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.33-41
    • /
    • 2018
  • This paper describes a new test rig for identification of rotordynamic force coefficients of squeeze film dampers (SFDs) in automotive turbochargers (TCs). Prior studies have mainly concentrated on relatively large-sized SFDs used in aircraft engines, turbocompressors, and turbopumps. The main objective of the current study is to propose a test rig for identification of dynamic force coefficients of small-sized SFDs (a journal diameter of ~11 mm). The current test rig consists of a journal, a SFD cartridge, four support rods, an upper structure, a data acquisition (DAQ) system, and an oil circulation unit. The annular gaps between the journal outer surface and SFD cartridge inner surface create SFD film lands. The damper has two parallel film lands separated by a central groove, having an axial length and depth of 3 mm. Each film land has a length of 4 mm with a $40{\mu}m$ radial clearance. The static load and dynamic impact tests identify the structural characteristics (i.e., stiffness and natural frequency) of the journal and assembled test rig. The measurements show good agreement with predictions. The SFD performance data from this test rig will be used to develop innovative TC rotor systems with improved NVH and reliability characteristics incorporating advanced SFD technology.

Bioequivalence Assessment of Roxithromycin Tablets in Healthy Korean Volunteers

  • Kwon Oh-Seung;Kim Hye-Jung;Pyo Hee-Soo;Chung Youn-Bok
    • Biomolecules & Therapeutics
    • /
    • v.14 no.1
    • /
    • pp.50-55
    • /
    • 2006
  • The objective of the study was to evaluate the bioequivalency between the $Rozid^{TM}$ Tablet (Ilhwa Pharm. Co., Ltd.) as a test formulation and the $Rulid^{TM}$ Tablet (Handok Pharm. Co., Ltd) as a reference formulation. Twenty-four healthy male volunteers were administered the formulations by the randomized Latin square crossover design, and the plasma samples were determined by a high performance liquid chromatography (HPLC) with fluorescence detector. $AUC_t,\;C_{max}\;and\;T_{max}$ were obtained from the time-plasma concentration curves, and log-transformed $AUC_t\;and\;C_{max}$ and log-untransformed $T_{max}$ values for two formulations were compared by statistical tests and analysis of variation. $AUC_t$ was determined to be $63.30{\pm}25.57{\mu}g.hr/ml$ for the test formulation and $64.02{\pm}29.27mg.hr/ml$ for the reference formulation. The mean values of $C_{max}$ for the test and reference formulations were $5.07{\pm}2.14\;and\;5.53{\pm}2.60{\mu}g/ml$, respectively. The $AUC_t,\;and\;C_{max}$ ratios of the test $Rozid^{TM}$ Tablet to the reference $Rulid^{TM}$ Tablet were -1.12% and -8.32%, respectively, showing that the mean differences were satisfied the acceptance criteria within 20%. The results from analysis of variance for log-transformed $AUC_t,\;and\;C_{max}$ indicated that sequence effects between groups were not exerted and 90% confidence limits of the mean differences for $AUC_t,\;and\;C_{max}$ were located in ranges from log 0.80 and log 1.25, satisfying the acceptance criteria of the KFDA bioequivalence. The RozidTM Tablet as the test formulation was considered to be bioequivalent to the RulidTM Tablet used as its reference formulation, based on $AUC_t,\;and\;C_{max}$ values.

Development of Runoff and Sediment Auto-calibration Tool for HRSM4BMP Model (HRSM4BMP 모형 유출/유사 자동 보정 툴 개발)

  • Kum, Donghyuk;Ryu, Jichul;Choi, Jaewan;Kang, Hyunwoo;Jang, Chun Hwa;Shin, Dong Suk;Lee, Jae Kwan;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • Recently, various Best Management Practices (BMPs) have been applied at a field to reduce soil erosion. Hourly Runoff and Sediment Model for Best Management Practices (HRSM4BMP) model could be used to evaluate soil erosion reduction for various agricultural BMPs at fields. Runoff and sediment yield from source areas have to be predicted with greater accuracies to evaluate sediment reduction efficiently with BMPs. To achieve this, the best parameters related with runoff and sediment modules of the HRSM4BMP model should be identified with proper calibration processes. Although manual calibration is often utilized in calibrating runoff and sediment using the HRSM4BMP, objective calibration method would be recommended. The purpose of the study was to develop an automatic calibration tool of the HRSM4BMP model with PARASOL method. This automatic calibration tool was applied to Bangdongri, Chuncheon-si to evaluate its calibration performance. The $R^2$, NSE and RMSE value for runoff estimation were 0.92, 0.92, $0.3m^3$, and for sediment yield estimation were 0.94, 0.94, 0.0027 kg. As shown in this result, automatic calibration tool of HRSM4BMP model would be used to determine the best parameters and can be used to simulate runoff and sediment yield with acceptable accuracies.

Real-time Monitoring System for Rotating Machinery with IoT-based Cloud Platform (회전기계류 상태 실시간 진단을 위한 IoT 기반 클라우드 플랫폼 개발)

  • Jeong, Haedong;Kim, Suhyun;Woo, Sunhee;Kim, Songhyun;Lee, Seungchul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.6
    • /
    • pp.517-524
    • /
    • 2017
  • The objective of this research is to improve the efficiency of data collection from many machine components on smart factory floors using IoT(Internet of things) techniques and cloud platform, and to make it easy to update outdated diagnostic schemes through online deployment methods from cloud resources. The short-term analysis is implemented by a micro-controller, and it includes machine-learning algorithms for inferring snapshot information of the machine components. For long-term analysis, time-series and high-dimension data are used for root cause analysis by combining a cloud platform and multivariate analysis techniques. The diagnostic results are visualized in a web-based display dashboard for an unconstrained user access. The implementation is demonstrated to identify its performance in data acquisition and analysis for rotating machinery.

Comparison of the Response Inhibitory Event Related Potential between Suicide Attempt and Ideation (자살 시도와 자살 사고 간 반응억제 사건유발전위 비교 연구)

  • Kim, Ji Sun;Kwon, Young Joon;Shim, Se-hoon
    • Anxiety and mood
    • /
    • v.16 no.1
    • /
    • pp.41-48
    • /
    • 2020
  • Objective : There have been limited scientific studies differentiating those who attempt suicide from those who think about suicide but do not attempt suicide. Altered event-related potential (ERP) performance, such as GoNogo ERP has been regarded as the neurocognitive processes associated with behavioral inhibition and poor impulse control. The purpose of this study was to investigate the association between Nogo ERP and suicide attempt. Methods : A total of 63 participants (33 participants with suicide ideation and 30 with suicide attempt) were recruited, and performed GoNogo tasks during the electroencephalogram measurement. Depression, anxiety, emotional regulation and impulsivity were evaluated by self-rating scales. The clinical measures and Nogo P3 component were compared between the groups. The correlational analyse was conducted to evaluate the relationship between the clinical characteristics and the Nogo P3 component. Results : Participants with suicide attempt significantly decreased the Nogo P3 amplitudes at the frontal-central electrode than participants with suicide ideation (p=0.004, FDR adjusted p=0.032). In the correlation analysis, the Nogo P3 amplitude at frontal-central electrode was correlated with the total score of the Barrett impulsivity scale (r=-0.383, p=0.002), attentional impulsivity (r=-0.365, p=0.003) and motor impulsivity (r=-0.389, p=0.002) subscales of the Barrett impulsivity scale. Conclusion : These findings suggest that the decreased Nogo P3 amplitude may be one of the candidates of biological marker for poor impulse control in those who attempt suicide.