• Title/Summary/Keyword: performance measurements

Search Result 2,639, Processing Time 0.034 seconds

The Correlation of Anthropometric Measurements, Physical Performance and Biochemical Measurements with Nutrient Intakes in Male College Students

  • Cho, Youn-Ok;Kim, Bo-Young
    • Nutritional Sciences
    • /
    • v.6 no.2
    • /
    • pp.113-117
    • /
    • 2003
  • Possible correlations between nutrient intake add health status-as assessed by anthropometric measurements, physical performance and biochemical measurements-were investigated, using 514 healthy young men aged 20 years old who had no apparent health problems. The intakes of nutrients were estimated using a three-day dietary recall method. Height and body weight were measured, and body mass index (BMI) was calculated. Physical performance was tested using sit-ups, push-ups, a loom sprint and a 1,500m run. When compared with the Korean recommended dietary allowances (Korean RDA), the subjects nutrient intakes were adequate except for calcium. The intake of calcium was 516.66$\pm$293.43mg/day, which is 73.80 % of the Korean RDA. The subjects averaged 174.51$\pm$7.07cm in height, 68.17$\pm$9.25 kg in body weight and 22.23$\pm$2.16 in BMI. The associations between nutrient intakes and anthropometric measurements, and between nutrient intakes and physical performance, were weak. The intake of vegetable fat was positively correlated to body weight, whereas the intake of carbohydrate was negatively correlated to BMI. The intake of carbohydrate was positively correlated to the level of performance in the loom sprint, and the intake of vegetable Int was positively correlated to the level of performance of sit-ups. No correlation was found between nutrient intakes and the following biochemical measurements of the blood: the levels of glucose, total protein, total cholesterol, triglyceride, hemoglobin and hematocrit. These results suggest that anthropometric measurements and level of physical performance can be associated with energy nutrient intakes, even in moderately active, well-nourished, young men. No correlation was found between nutrient intake and biochemical measurements, probably because all subjects had a reasonably well-balanced diet.

Spacecraft Precision Attitude Determination using UVF Measurements

  • Lee, Hun-Gu;Yoon, Jae-Cheol;Shin, Dong-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1881-1886
    • /
    • 2005
  • This paper proposes a novel approach of a precision attitude determination algorithm using UVF (Unit Vector Filter) measurements. The proposed method is superior to the conventional QUEST measurements based approaches because the estimation performance can be greatly enhanced by selecting brighter stars having better noise characteristics. The performance comparison with QUEST measurements is made to verify the usefulness of the proposed algorithm.

  • PDF

Measurements Preprocessing for Bearing and Frequency Target Motion Analysis (BFTMA를 위한 측정데이터 전처리 기법 연구)

  • Kim In-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.2 s.17
    • /
    • pp.22-31
    • /
    • 2004
  • In this paper, the measurements preprocessing algorithm for the fading of bearing and frequency measurements is proposed, which can improve the performance of BFTMA(Bearing and Frequency Target Motion Analysis). The fading and detection relation between bearing and frequency are rigorously established for measurements preprocessing, and BFTMA can be carried out the estimation of target motion by using measurements preprocessing. Batch estimation with bearing and frequency using the proposed algorithm can be applied to estimate the initial target states despite of the fading of frequency measurement. Simulation results show that BFTMA using the proposed measurements preprocessing has superior estimation performance, compared with batch estimation using only bearing measurements.

An Attitude Error Estimation Performance Comparison of Tightly Coupled INS/GPS Navigation System using Different Measurements (강결합 방식의 INS/GPS 시스템에서의 자세 오차 추정 성능 비교)

  • Yu, Hae-Sung;Kim, Cheon-Joong;Yoo, Ki-Jeong;Lee, Youn-Seon;Park, Heung-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.49-54
    • /
    • 2011
  • This paper addresses the performance comparisons of the GPS pseudorange and pseudorange rate measurements in the tightly coupled INS/GPS Navigation systems. Even though the two measurements have the same ability in estimating level attitude errors, pseudorange rate has an advantage in improving estimating heading attitude error performance. The performance of pseudorange and pseudorange rate measurements is compared in numerical simulations and van test.

Performance of LOB-based Emitter Localization Using Linear LSE Algorithms (선형 LSE 알고리즘을 이용한 신호원 위치 추정 성능)

  • Lee, Joon-Ho;Kim, Min-Cheol;Cho, Seong-Woo;Kim, Sang-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, the well-known LOB-based emitter localization using linear LSE algorithm is numerically implemented and the heuristic guidelines for the parameter values to achieve 1% RMS error are presented. In the simulation, we changed the total observation durations for LOB measurements, time interval between successive LOB measurements and sensor trajectories. The effects of the time interval of LOB measurements, the time duration of the LOB measurements and the angle of flight path arc on the performance are illustrated. The dependence of the performance on the various parameters is investigated and rule-of-thumbs for the parameter values corresponding to 1% RMS error are presented for each simulation condition.

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Effect of a Mediterranean-style diet on the exercise performance and lactate elimination on adolescent athletes

  • Gizem Helvaci;Asli Ucar;Mehmet Mesut Celebi;Haydar Cetinkaya;Ayse Zulal Gunduz
    • Nutrition Research and Practice
    • /
    • v.17 no.4
    • /
    • pp.762-779
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Mediterranean diet is an environmentally friendly and healthy diet model. The diet offers many vegetables, fruits, nuts, and olive oil to consumers. In addition, it provides moderate amounts of fish and chicken, smaller quantities of dairy products, red meat, and processed meat. The Mediterranean diet has a high anti-inflammatory and antioxidant content, and it causes many physiological changes that can provide a physical performance advantage. This study examined the effects of a 15-day menu, which was planned using foods with a low acid load within the Mediterranean diet rules, on the exercise performance, lactate elimination, anthropometric measurements, and body composition. SUBJECTS/METHODS: Fifteen professional male athletes between the ages of 13 and 18, who were engaged in ski running, were included in the experimental study. Dietary intervention was applied for 15 days. The athlete performances were evaluated by applying the vertical jump test, hand grip strength, 20 meters shuttle run test, and Borg fatigue scale. After the shuttle run test (every 3 min for 30 min), blood was drawn from the finger, and the lactate elimination time was calculated. Performance and lactate measurements, body analysis, and anthropometric measurements were taken before and after dietary intervention. RESULTS: The vertical jump height and hand grip strength increased after the intervention (P < 0.05). The test duration, total distance, the number of shuttles, and maximum oxygen consumption parameters of the shuttle run test increased (P < 0.05). After the intervention, the athletes' perceived fatigue scores decreased in several stages of the shuttle run test (P < 0.05). The lactate elimination time and athlete's body composition were similar in repeated measurements (P > 0.05). In the last measurements, the upper middle arm circumference decreased while the height of the athletes increased (P < 0.05). CONCLUSIONS: These results show that the Mediterranean diet is a safe and feasible dietary approach for aerobic performance and strength increase.

The Performance Analysis of MPDA in Out of Sequence Measurement Environment (Out of Sequence Measurement 환경에서의 MPDA 성능 분석)

  • Seo, Il-Hwan;Lim, Young-Taek;Song, Taek-Lyul
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.9
    • /
    • pp.401-408
    • /
    • 2006
  • In a multi-sensor multi-target tracking systems, the local sensors have the role of tracking the target and transferring the measurements to the fusion center. The measurements from the same target can arrive out of sequence called the out-of-sequence measurements(OOSMs). Out-of-sequence measurements can arise at the fusion center due to communication delay and varying preprocessing time for different sensor platforms. In general, the track fusion occurs to enhance the tracking performance of the sensors using the measurements from the sensors at the fusion center. The target informations can wive at the fusion center with the clutter informations in cluttered environment. In this paper, the OOSM update step with MPDA(Most Probable Data Association) is introduced and tested in several cases with the various clutter density through the Monte Carlo simulation. The performance of the MPDA with OOSM update step is compared with the existing NN, PDA, and PDA-AI for the air target tracking in cluttered and out-of-sequence measurement environment. Simulation results show that MPDA with the OOSM has compatible root mean square errors with out-of-sequence PDA-AI filter and the MPDA is sufficient to be used in out-of-sequence environment.

Discussions on Availability of Weather Information Data and Painting Effect of Existing 8,600 TEU Container Ship Using Ship Performance Analysis Program

  • Shin, Myung-Soo;Ki, Min Suk;Lee, Gyeong Joong;Park, Beom Jin;Lee, Yeong Yeon;Kim, Yeongseon;Lee, Sang Bong
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.377-386
    • /
    • 2020
  • This paper discusses the effectiveness of onboard measurements and data extracted from weather information for speed-power analysis. Furthermore, validation results of hull and propeller cleaning and painting during dry-docking are discussed. Wind and wave information can be obtained from onboard measurements or weather information from the National Oceanic and Atmospheric Administration (NOAA). The weather information of a specified position and time is extracted from NOAA weather data and compared with onboard measurements. In addition, to validate the effects of hull cleaning and painting during dry-docking, speed-power analysis results of before and after dry-docking are compared. The results show that both onboard measurements and weather information show acceptable reliability when added resistance and speed-power analysis results are compared with each other. Moreover, the ship performance analysis (SPA) software clearly shows the effects of hull cleaning and painting, and it can provide reliable analysis results with either onboard measurements or weather information. In conclusion, it is confirmed that the analysis method and SPA software used in this study are effective in analyzing the ship's speed-power performance.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF