• Title/Summary/Keyword: performance experiment

Search Result 9,047, Processing Time 0.04 seconds

A Design and Implementation of Fuzzy Controller for Temperature Control (온도 제어를 위한 퍼지 제어기의 설계 및 구현)

  • Seo, Kang-Myun;Park, Sang-Sun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.732-734
    • /
    • 1997
  • This paper describes the design and implementation of a fuzzy temperature control system to control the water temperature in plant. For evaluating the performance of a fuzzy controller, the experiment results of a fuzzy controller are compared with these of a conventional PID controller which provides an auto-tuning function. The experiment results show that the proposed controller has a good control performance and is robust to external disturbance.

  • PDF

Theoretical & Experimental Study on the Air-Type Nonmetallic Collectors. (비금속 공기식 집열기의 이론 분석 및 성능실험)

  • Lee, Dong-Won;Lee, Jong-Ho
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.77-86
    • /
    • 1986
  • In this study, theoretical & Experiemental Analysis on three different air type solar collectors (One of metallic material: AI, two of non-metallic materials; GIWA & Slate) are performed. The results of three different collectors show the similiar performance in spite of different absorber material. The results of experiment are coincided with the theoretical results, and thus it is possible to estimate the performance of collector for the other experiment measuring variables. As a result, the thermal conductivity has no influence on the collector efficiency, because air, heat transfer medium, flows through over the whole surface of absorber plate.

  • PDF

Performance Modelling in an Eye-gaze Controlled Input Device (주시선을 이용한 입력기기의 수행도 모델링)

  • 박경수;반영환;이경태
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.346-350
    • /
    • 1997
  • Index of performance is dervied from consideration of movement times in routine selection tasks. The discrete movement task employed in this study consisted of moving a cursor from the home position to targets located 6.8, 15.9, 25.0, and 34.0 cm. The target widths were 2.3, 4.5, and 6.8cm. Eight subjects with nomovement disabilities took part in the experiment. Fitts' law is found to be applicable in this experiment.

  • PDF

The Study on Performance Characteristics of NH3 Refrigeration System Using Optimum Heat Exchanger (고밀도 열교환기를 이용한 $NH_3$냉동장치의 성능 특성 연구)

  • Lee, Seung-Jae;Jeon, Sang-Sin;Kwon, Il-Wook;Lee, Jong-In;Ha, Ok-Nam
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1276-1281
    • /
    • 2004
  • Nowadays CFCs and HCFCs refrigerants are restricted because it cause depletion of ozone layer. Accordingly, this experiment apply the ammonia gas and not CFCs and HCFCs for refrigerant to study the performance characteristic from the superheat control and improve the energy efficiency from the high performance. The condensing pressure of refrigeration system is increased from 15.0bar to 16bar by 0.5bar and superheat temperature is increased from $0^{\circ}C$ to $10^{\circ}C$ by $1^{\circ}C$ at each condensing pressure. As the result of experiment, when the superheat temperature is $0^{\circ}C$ at each condensing pressure, the refrigeration system has the high performance.

  • PDF

An Experimental Study on the Measurement Performance of Coordinate Measuring Machine (3 차원 좌표 측정기의 측정 성능에 대한 실험적 연구)

  • Lee, Seung-Pyo;Kang, Hyung-Joo;Ha, Sung-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.47-54
    • /
    • 2009
  • In the manufacturing industry, there has been a significant increase in the use of coordinate measuring machines(CMM). In this paper, the sources of CMM measurement performance are discussed. The effects of workpiece position, length and orientation are analyzed by using the design of experiments. Both a fractional factorial design and a factorial design are employed to conduct the experimental study. The analysis of variance is performed to determine the significance of factors in the experiment and regression analysis is applied to make the measurement approximate model. The results show that position along the Z axis, length and orientation affect the CMM measurement performance.

A basic study for the development of Integrated Seakeeping Performance Evaluation System on board the ship (선박탑재용 종합내항성능 평가시스템 개발을 위한 기초적 연구)

  • 조익순;이충로;김순갑
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.3
    • /
    • pp.103-111
    • /
    • 2000
  • From a ship's safe operation point of view, it is very important to estimate the navigational safety in a seaway. The seakeeping performance can be defined as the ability of a ship to go to sea, and to accomplish its missions successfully and safely even in adverse environmental conditions. There are several factors presently adopted for evaluating seakeeping performance. But a hardware of the system considering all these factors has not been developed since some of them can not be measured by sensors. In this paper, a synthetic method of evaluating navigational safety is developed by measuring the vertical and lateral acceleration. An experiment by using real measuring carried out on board the T/S 'HANNARA' The equipment was measured every 4 hours for more than 30 minutes the acceleration by accelerometer, analyzed its acceleration values and calculated navigational dangerousness. As the results of this on board experiment, the system is carried conviction to be useful as evaluating seakeeping performance.

  • PDF

Use of Mobile Devices in the Performance of Group Decision-Making under Contextual Pressure

  • Kwon, Oh-Byung;Kim, Tae-Kyung;Kim, Choong-Rhyun
    • Journal of Information Processing Systems
    • /
    • v.3 no.2
    • /
    • pp.64-72
    • /
    • 2007
  • Mobile technology appears promising as a method to promote group performance in circumstances dependent on time, but not member proximity. However, the success of mobile technology in group decision-making situations has not yet been proven. This paper aims to see how mobile technology affects the performance of group decision-making tasks that should be resolved urgently and/or sources of idea are disconnected with on-line network. Laboratory experiment was used to investigate the effects of mobile factors on group decision-making. The results from the experiment supported the proposition that pressures of time and location play a significant role in the assessment of group decision performance measures. We found that the adoption of mobile technology to group decision-making procedures might be competitive when group decision-making tasks are urgent and sources of idea are disconnected with on-line network, even though mobile technology is not a panacea on which to depend when designing group decision-making.

A Study of air Sterilization System in Personalized Office Using Simulation (시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구)

  • Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.

PERFORMANCE OF BROILERS AND LAYERS FED LOCALLY PRODUCED FISH WASTE MEAL IN WESTERN SAMOA

  • Ochetim, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.1
    • /
    • pp.91-95
    • /
    • 1992
  • Two experiments were conducted to evaluate the performance of broilers and layers fed locally produced fish waste meal (LFWM) in Western Samoa. LFWM, which was produced by mincing and oven drying of rejects from filleted fish, was included in both broiler and layer diets at the complete expense of imported meat and bone meal (MBM). The experiments were of a completely randomised design. In experiment 1, 120 day-old Strabro broiler chicks were raised to 49 days of ages. In experiment 2, 80 Shaver 288 pullets, 20 weeks of age, were housed in pairs in cages and raised up to 72 weeks of age. There were no differences (p > 0.05) in performance of broilers as measured in terms of final bodyweights, feed intake, feed efficiency and carcass yield between the two diets. Similarly, no differences (p > 0.05) existed in egg production, egg weight and feed required per kilogramme of eggs. It is concluded that LFWM is nutritionally as good as imported MBM and could be used to completely replace MBM in broiler and layer diets.

The Study on Performance Characteristics due to the Superheat Temperature of $NH_3$ Refrigeration System (과열도 변화에 의한 $NH_3$ 냉동장치의 성능특성 연구)

  • Jeong, Sang-Sin;Kwon, Il-Wook;Ha, Ok-Nam
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1334-1339
    • /
    • 2004
  • Nowadays CFCs and HCFCs refrigerants are restricted because it cause depletion of ozone layer. Accordingly, this experiment apply the $NH_3$ gas and not CFCs and HCFCs for refrigerant to study the performance characteristic from the superheat control and improve the energy efficiency from the high performance. The condensing pressure of refrigeration system is increased from 14.5bar to 16bar by 0.5bar and superheat temperature is increased from $0^{\circ}C$ to $10^{\circ}C$ by $1^{\circ}C$ at each condensing pressure. As the result of experiment, when the superheat temperature is $1^{\circ}C$ at each condensing pressure, the refrigeration system has the high performance.

  • PDF