• Title/Summary/Keyword: performance characterization

Search Result 1,052, Processing Time 0.033 seconds

Synthesis and Characterization of Tungsten Trioxide Films Prepared by a Sol-Gel Method for Electrochromic Applications

  • Kim, Tae-Ho;Nah, Yoon-Chae
    • Journal of Powder Materials
    • /
    • v.22 no.5
    • /
    • pp.309-314
    • /
    • 2015
  • Tungsten trioxide thin films are successfully synthesized by a sol-gel method using tungsten hexachloride as precursors. The structural, chemical, and optical properties of the prepared films are characterized by scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and UV-Vis spectrophotometry. The electrochemical and electrochromic properties of the films before and after heat treatment are also investigated by cyclic voltammetry, chronoamperometry, and in situ transmittance measurement system. Compared to as-prepared films, heat-treated tungsten trioxide thin films exhibit a higher electrochemical reversibility of 0.81 and superior coloration efficiency of $65.7cm^2/C$, which implies that heat treatment at an appropriate temperature is a crucial process in a sol-gel method for having a better electrochromic performance.

Fabrication and Characterization of Cold Cathode Electron-gun of CRT using Mo-tip Field Emitter Array (몰리브덴 팁 전계 방출 소자를 이용한 CRT의 냉음극 전자총의 제조 및 특성 평가)

  • Ju, Byeong-Kwon;Kim, Hoon;Seo, Sang-Won;Park, Jong-Won;Lee, Yun-Hi;Kim, Nam-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.409-413
    • /
    • 2001
  • In the electron-gun of CRT, the Mo-tip FEA was employed as cold cathode in order to replace the conventional thermal cathode. The Mo-tip FEA was designed and fabricated according to CRT specification and mounted on the electron-gun. It was known that fabricated cold cathode electron-gun showed better performance in terms of maximum emission current and switch-on time when compared with the ones of thermal cathode electron-gun, but some geometrical structures in the inside of electron-gun must be changed to reduce the gate leakage current. Finally, the potential applicability was guaranteed by means of operating the 19 inch-sized LG-color CRT using the fabricated cold cathode electron-gun.

  • PDF

Characteristics of COMS MI Radiometric Calibration

  • Cho, Young-Min
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.71-74
    • /
    • 2006
  • Communication Ocean Meteorological Satellite (COMS) is planned to be launched onto Geostationary Earth Orbit in 2008. The meteorological imager (MI) is one of COMS payloads and has 5 spectral channels to monitor meteorological phenomenon around the Korean peninsular intensively and of Asian-side full Earth disk periodically. The MI has on-board radiometric calibration capabilities called 'blackbody calibration' for infrared channels and 'space look' for infrared/visible channels, and radiometric response stability monitoring device called 'albedo monitor' for visible channel. Additionally the MI has on-board function called 'electrical calibration' for the check of imaging path electronics of both infrared and visible channels. The characterization of MI performance is performed to provide the pre-launch radiometric calibration data which will be used for in-orbit radiometric calibration with the on-board calibration outputs. The radiometric calibration of the COMS MI is introduced in the view point of instrument side in terms of in-orbit calibration devices and capabilities as well as the pre-launch calibration activities and expected outputs.

  • PDF

SILICONE POLYMER FOR ANTIFOULING/FOULING RELEASE MARINE COATING APPLICATION

  • Choi, Seok-Bong;Jepperson, John;Thomas, Johnson;Jarabek, Laura;Chisholm, Bret;Boudjouk, Philip
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.378-378
    • /
    • 2006
  • The preparation, characterization, and bio-testing of biocide incorporated silicone coatings for marine applications have been conducted. Derivatives of the biocide, Triclosan (5-chloro-2-(2, 4-dichlorophenoxy) phenol), were used to covalently attach the biocide moiety to a silicone backbone. The synthetic process allowed for control of the resulting coating's mechanical properties as well as antifouling/fouling release performance in laboratory and ocean site testing. The test results showed significantly reduce macro fouling with sustained fouling release characteristics for the coatings produced.

  • PDF

Preparation and Characterization of Polyimide/Carbon-Nanotube Composites

  • Kim, Bong-Sup;Bae, Sang-Hoon;Park, Young-Hwan;Kim, Ji-Heung
    • Macromolecular Research
    • /
    • v.15 no.4
    • /
    • pp.357-362
    • /
    • 2007
  • Polyimide/carbon nanotube (CNT) composite films, for potential use in high performance microelectronics and aerospace applications, were prepared by mixing a polyisoimide (PII) solution and a CNT suspension in NMP, followed by casting, evaporation and thermal imidization. The CNTs were modified by a nitric acid treatment to improve the thermal and electrical properties, as well as to provide good dispersion of the CNTs in a polymer matrix. The formation of functional groups on the modified CNT was confirmed by Raman spectroscopy. Scanning electron microscopy revealed the modified CNTs to be well dispersed in the polyimide matrix, with a uniform diameter of ca. 50 nm. The thermal stability of the films containing the CNTs was improved due to the enhanced interfacial interaction and good dispersion between the polyimide matrix and modified CNTs. In addition, the thermal expansion coefficient of the composites films was slightly decreased, but the dielectric constants increased linearly with increasing CNT content.

Evaluation of Primary Clarifier by Wastewater TSS Characterization (수질 특성(TSS) 파악을 통한 1차 침전지 성능 평가 (TSS 농도를 중심으로))

  • Lee, Byonghi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.363-369
    • /
    • 2009
  • In order to evaluate primary clarifier performance on TSS(Total Suspended solids) removal, four different sampling sets were collected as part of this study; (1) weekly test, (2) the diurnal sampling, (3) the settling velocity distribution sampling. Primary effluent TSS($TSS_{PE}$) and non settleable TSS($TSS_{NON}$) concentrations were averaged 160 and 75.5 mg/L, respectively. These data suggest approximately 85 mg/L TSS can be removed more. Average $TSS_{NON}$, $TSS_{PE}$, and Dispersed TSS(DTSS) concentrations(75.5, 160, and 104 mg/L, respectively) suggest that 28.5 mg/L of TSS difference attributable to poor flocculation, whereas 56 mg/L of TSS difference attributable to poor hydraulics within primary clarifier. In this study, equations for maximum TSS removal efficiency and effluent TSS concentration were suggested and compared with experimented data.

Overview of Disturbance Observation Techniques for Linear and Nonlinear Systems (선형 및 비선형 시스템을 위한 외란 관측 기법 개관)

  • Lee, Kooksun;Ha, Wonseok;Back, Juhoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.5
    • /
    • pp.332-338
    • /
    • 2016
  • In industrial applications, there are disturbances and uncertainties that bring unfavorable effects to achieving the desired performance of a closed-loop system. Not surprisingly, many researchers have developed various techniques to attenuate influence of the disturbance. One intuitive idea is to design a disturbance estimator, called a disturbance observer, and cancel the effects by feedback action. This paper is a survey of disturbance observers and related methods. We categorize existing methods by design approach, applied system, and characterization of disturbance. Several disturbance observers are explained by simple examples. The readers could use this paper to help understand the configurations of representative disturbance observer methods.

Characterization of the Mechanical Properties of Fiber-Reinforced Lightweight Concrete (섬유보강 경량골재 콘크리트의 역학적 특성에 관한 실험적 연구)

  • Lee, Haeng-Ki;Song, Su-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.461-464
    • /
    • 2006
  • An experimental study is conducted to charaterize the mechanical properties of a fiber-reinforced, lightweight concrete (FRLAC) that is produced without an autoclave process. The FRLAC enhances the strength of lightweight cellular concrete by adding polypropylene fibers. A series of compressive strength tests on cylindrical specimens are carried out to characterize the compressive strength and the modulus of elasticity of the FRLAC. Specifically, various mixing rates of a foam agent are applied in casting of the specimens to investigate the influence of the mixing rate of the foam agent on the performance of the FRLAC and to determine the optimal mixing rate of the foam agent.

  • PDF

Characterization of PDP Performance Prepared by Vacuum In-line Sealing Technology

  • Kwon, Sang-Jik;Kim, Jee-Hoon;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • v.4 no.4
    • /
    • pp.19-24
    • /
    • 2003
  • By using vacuum in-line driving and photoluminescence measuring system, we have examined the electrical and optical characteristics of plasma display panel produced by vacuum in-line sealing technology. In addition, the relationship between luminous efficiency and base vacuum level before filling discharge gas was analyzed. In the case of base vacuum level of $1.33{\times}10^{-1}$ Pa, the firing voltage of a 2-inch diagonal PDP panel was ranged from 312 to 343 V depending on the discharge gas pressure of $2.667{\times}10^4$ to $4{\times}10^4$ Pa at room temperature, Whereas in the case of $1.33{\times}10^{-4}$ Pa, the firing voltage was reduced by 40 V and luminescence was improved slightly.