• Title/Summary/Keyword: perceptual quality

Search Result 344, Processing Time 0.042 seconds

No-reference Perceptual Quality Assessment of Digital Image (디지털 영상의 인지적 무참조 화질 평가 방법)

  • Lim, Jin-Young;Chang, Ho-Seok;Kang, Dong-Wook;Kim, Ki-Doo;Jung, Kyeong-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.13 no.6
    • /
    • pp.849-858
    • /
    • 2008
  • In this paper, a no-reference perceptual metric is proposed for image quality assessment. It measures the amount of overall blockiness and blurring of the image and evaluates the amount of ringing, staircase, and mosaic noises around the strong edges. Finally, the individual scores are combined by a fuzzy integral to generate the final quality score of the image. The quality scores obtained by the proposed algorithm show strong relationship with the MOS(Mean Opinion Score) values by experts.

Analysis of Image Quality Based on Perceptual Vision

  • Xue, Liqin;Hua, Yuning;Qi, Yaping
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1494-1496
    • /
    • 2007
  • This paper deals with image quality analysis considering the impact of psychological factors involved in assessment. The attributes of image quality requirement were partitioned according to the visual perception characteristics and the preference of image quality were obtained by the factor analysis method. The features of image quality which support the subjective preference were identified, The adequacy of image is evidenced to be the top requirement issues to the display image quality improvement.

  • PDF

Perceptual Photo Enhancement with Generative Adversarial Networks (GAN 신경망을 통한 자각적 사진 향상)

  • Que, Yue;Lee, Hyo Jong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.522-524
    • /
    • 2019
  • In spite of a rapid development in the quality of built-in mobile cameras, their some physical restrictions hinder them to achieve the satisfactory results of digital single lens reflex (DSLR) cameras. In this work we propose an end-to-end deep learning method to translate ordinary images by mobile cameras into DSLR-quality photos. The method is based on the framework of generative adversarial networks (GANs) with several improvements. First, we combined the U-Net with DenseNet and connected dense block (DB) in terms of U-Net. The Dense U-Net acts as the generator in our GAN model. Then, we improved the perceptual loss by using the VGG features and pixel-wise content, which could provide stronger supervision for contrast enhancement and texture recovery.

A Perceptual Rate Control Algorithm with S-JND Model for HEVC Encoder (S-JND 모델을 사용한 주관적인 율 제어 알고리즘 기반의 HEVC 부호화 방법)

  • Kim, JaeRyun;Ahn, Yong-Jo;Lim, Woong;Sim, Donggyu
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.929-943
    • /
    • 2016
  • This paper proposes the rate control algorithm based on the S-JND (Saliency-Just Noticeable Difference) model for considering perceptual visual quality. The proposed rate control algorithm employs the S-JND model to simultaneously reflect human visual sensitivity and human visual attention for considering characteristics of human visual system. During allocating bits for CTU (Coding Tree Unit) level in a rate control, the bit allocation model calculates the S-JND threshold of each CTU in a picture. The threshold of each CTU is used for adaptively allocating a proper number of bits; thus, the proposed bit allocation model can improve perceptual visual quality. For performance evaluation of the proposed algorithm, the proposed algorithm was implemented on HM 16.9 and tested for sequences in Class B and Class C under the CTC (Common Test Condition) RA (Random Access), Low-delay B and Low-delay P case. Experimental results show that the proposed method reduces the bit-rate of 2.3%, and improves BD-PSNR of 0.07dB and bit-rate accuracy of 0.06% on average. We achieved MOS improvement of 0.03 with the proposed method, compared with the conventional method based on DSCQS (Double Stimulus Continuous Quality Scale).

The Effect of An Increase of Closed Quotient on Improvement of Voice Quality after Type I Thyroplasty in Patients with Unilateral Vocal Cord Paralysis (일측 성대마비 환자에서 성대내전술 후 성대접촉율의 증가가 음질 개선에 미치는 영향)

  • Kim, Han-Su;Choi, Seung-Hee;Lim, Jae-Yol;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.16-20
    • /
    • 2004
  • Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.

  • PDF

The Study of Tonsil Affected Voice Quality after Tonsillectomy (편도적출술로 음성변화가 올 수 있는 편도 상태에 관한 연구)

  • 안철민;정덕희
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.32-37
    • /
    • 1998
  • Tonsillectomy is the one of operation that is performed the most commonly in otolaryngology field. Many changes that include range of voice, tone, voice quality and resonance were made by tonsillectomy. Sometimes, any patients taken tonsillectomy has suffer from these voice problem after tonsillectomy. However there are less study for these problems until now. Then, we studied to find the anatomical findings that affected the voice quality when tonsillectomy was performed. We evaluated the voice in 2 groups, one is the group showed the normal pharyngeal space by using the transnasal fiberscopy, the other is group showed medially bulging tonsil at pharyngeal cavity by using same method, with perceptual evaluation, nasalance score, nasality, oral formant and nasal formant. We used the computerized speech analysis system, the nasometer and the spectrogram in the CSL program. We could not find any differences in perceptual evaluation between two groups. But objective measures were provided. Nasalance score and nasality on the nasometric analysis were increased significantly and oral formant on the spectrogram was changed singnificantly after tonsillectomy in Group 2. Authors thought medially bulging tonsil in the pharynx is able to affect the voice quality after tonsillectomy when we evaluted through the nasal cavity by the using of fiberscopy and this evaluation would be important especially in singers.

  • PDF

Emotional Image Quality Evaluation Technology for Display Devices

  • Lee, Eun-Jung;Lee, Seung-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.10-17
    • /
    • 2009
  • In this paper, we explained the relation between evaluating display device and emotional image quality evaluation in human perceptual view. It is also suggested two emotional image quality evaluation method of display reflecting human visual function. One is the color space of CIECAM02 and the other is capturing moving image. It is necessary to standardize the evaluation methods of image quality based on emotional evaluation.

VoIP Quality Metric and Quality-based Accounting Scheme (VoIP 품질 측량 도구 및 품질 기반의 요금 부과 방안 연구)

  • Jung, Youn-Chan;Ann, Ibanez Al
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1B
    • /
    • pp.27-34
    • /
    • 2010
  • As VoIP systems move to wireless environments with much higher average packet loss rates than wired networks, it becomes less possible for the network to assure a reasonable QoS. So, real-time quality monitoring for mobile VoIP applications is an important issue to be explored. In this paper, we explore perceptual quality dependency on two parameters: the burst loss rate and average burst length. Also, we propose a simple 'moving average' approach with $\alpha$ aiming to measure those parameters on real-time basis. In order to find how accurately the two parameters measured estimate the real perceptual quality, we compare actual measured PESQ scores with estimated value by matching the measured quality metric to the trained MOS table. Finally, we propose the quality-based accounting system, which can set obvious continuities between quality and billing.

Experimental Study on Subjective Sound Quality Evaluation of Vehicle Noises (승용차소음의 주관적 음질평가 실험연구)

  • Choe, Byongho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1223-1232
    • /
    • 2004
  • This study is directed toward determining the number and characteristics of psychologically meaningful perceptual dimensions required for assessing the sound quality with respect to vehicle noises, and toward identifying the acoustical and/or psychoacoustical bases underlying the preference and similarity judgments. For the purpose of analyzing the paired comparison data produced by subjective ratings we used nonmetric multidimensional scaling(MDS). The perceptual dimensions based upon preference ratings could explain 76.3 % of the variance by maximum dB(A) and sharpness acum. The correlation between objective and subjective positions of the stimuli is $R^2$=0.97(F(1,13)=195.45, p < .01), corrected $R^2$=0.93. The less the intensity of the stimulus the more becomes the subjective Position would be over-estimated relative to the objective one. The same is valid for the opposite case. The perceptual dimensions based upon similarity judgments could be accounted for 47.8 % and 23.5% of the variance, each of which might be a match for the maximum dB(A) and the sharpness acum, respectively. The correlation between objective and subjective positions of the stimuli is $R^2$=0.94(F(1,13)=92.38, p < .01), corrected $R^2$=0.87. The more the intensity of the stimulus the more becomes the subjective position would be over-estimated relative to the objective one. The same is valid for the opposite case. In other words, it is likely that the larger the amount of two stimuli which to compare would be judged similar. So far it should be further clarified that whether the relationship between preference ratings and psychological distances nay be optimized through which psycho-physical models.

Performance Improvement of Perceptual Filter Using Noise Energy Control (잡음 에너지 제어를 통한 지각 필터 성능 개선)

  • Seo Joung-Kook;Cha Hyung-Tai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • In this paper, we propose an algorithm that improves a tone quality of a noisy audio signal in order to enhance a Performance of perceptual filter using noise energy control. Most of the algorithms which were proposed by the other researchers usually applied a filter using the noise energy acquired from a silent range. In this case. the improvement rate of tone quality decreases if the noise energy is changed by the magnitude or environment variation in a signal frame. But the Proposed method Provides the means to find a food estimated noise through energy control of the estimated noise which is obtained from a silent range. Also we can get the enhancement of tone qualify in low frequency band unlike other methods. To show the performance of the Proposed algorithm, various input signals which had a different signal-to-noise ratio (SNR) such as 5dB, l0dB, 15dB and 20dB were used to test the proposed algorithm. With the proposed algorithm, we could confirm the enhancement of tone quality in terms of segmental SNR (SSNR). noise-to-mask ration (NMR) and mean opinion score (MOS) test.